Panasonic Kx Ta824 Installation Manual
Have a look at the manual Panasonic Kx Ta824 Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
2.3 Installing Optional Service Cards Installation Manual 51 2.Lift the edge of the card while holding the catch open. (Do not touch the circuit board of the card during the operation.) Programming Manual References [599] Clear All OGMs of DISA 8.5 DISA OGM Clear Feature Manual References 1.1.41 Direct Inward System Access (DISA) 1.1.88 Outgoing Message (OGM) for DISA 1.1.112 Station Message Detail Recording (SMDR)
![](/img/blank.gif)
2.3 Installing Optional Service Cards 52 Installation Manual 2.3.8 2-Channel Voice Message Card (KX-TA82492) Function Provides 60 minutes of recording time (2 channels) for messages using the Built-in Voice Message Feature. 1.Loosen the screws and open the top and bottom front covers. (→ 2.2.3 Opening/Closing Covers) 2.Slide the card between the guiderails until it clicks, and attach the connector to it. Note Use extra care to make sure you do not damage the part of the case marked with a circle. 3.Close the covers and secure the screws. (→ 2.2.3 Opening/Closing Covers) 4.Initialize the 2-Channel Voice Message Card through system programming. (→ 2.10.1 Starting the Advanced Hybrid System) Note To uninstall the card, follow the instructions illustrated below. 1.Push the catch on the side of one guiderail in the direction of the arrow to release it. 2.Lift the edge of the card while holding the catch open. (Do not touch the circuit board of the card during the operation.) KX-TA82492 Guiderail 1 2
![](/img/blank.gif)
2.3 Installing Optional Service Cards Installation Manual 53 Programming Manual References [808] BV Card Initialization 8.6 BV Card Initialization Feature Manual References 1.1.8 Built-in Voice Message (BV)
![](/img/blank.gif)
2.4 Connecting Outside (CO) Lines 54 Installation Manual 2.4 Connecting Outside (CO) Lines 2.4.1 Connecting Outside (CO) Lines Connection 1.Insert the modular plugs of the telephone line cords (2-conductor wiring) into the outside (CO) line jacks. 2.Connect the line cords to the terminal board or the modular jacks from the telephone company. To Terminal Board or Modular Jacks from the Telephone CompanyTRT: Tip R: Ring TEL Jack for Outside (CO) Line
![](/img/blank.gif)
2.5 Connecting Extensions Installation Manual 55 2.5 Connecting Extensions 2.5.1 Connecting Extensions Extension jacks can be used for proprietary telephones (PTs), Direct Station Selection (DSS) Consoles, single line telephones (SLTs), and Voice Processing Systems. Note Connect a display-equipped PT to extension jack 01, as this extension is automatically designated as the manager extension. Connection Insert the modular plugs of the telephone line cords (2- or 4-conductor wiring) into the modular jacks on the PBX. Maximum Cabling Distance of Extension Wiring (Twisted Cable) To Extensions THRL H: High T: Tip R: Ring L: Low TEL Jack for Extension Cable Max. Distance 26 AWG: 140 m (459 ft) 24 AWG: 229 m (751 ft) 22 AWG: 360 m (1181 ft) CAT 5: 229 m (751 ft) Cable Max. Distance 26 AWG: 698 m (2289 ft) 24 AWG: 1128 m (3700 ft) 22 AWG: 1798 m (5897 ft) CAT 5: 1128 m (3700 ft)PT and DSS Console SLT
![](/img/blank.gif)
2.5 Connecting Extensions 56 Installation Manual 2- or 4-conductor wiring is required for each extension as listed below. There are 4 pins that can be used for connection: T (Tip), R (Ring), H (High) and L (Low). Note If a telephone or answering machine with an A-A1 relay is connected to the PBX, set the A-A1 relay switch on the telephone or answering machine to the OFF position.Telephone Wiring SLT 1-pair wire (T, R) PT (such as KX-T7736) 2-pair wire (T, R, H, L) DSS Console 1-pair wire (H, L)
![](/img/blank.gif)
2.5 Connecting Extensions Installation Manual 57 2.5.2 Connecting Extensions in Parallel Any single line telephone (SLT) can be connected in parallel with a proprietary telephone (PT) to a Hybrid Port as follows: Note An answering machine, fax machine or modem can be connected in parallel with a PT in the same way as an SLT can. Feature Manual References 1.1.97 Paralleled Telephone To a Hybrid Port 4-Conductor Wiring Cord Connect pins T, R, H, and L.2-Conductor Wiring Cord Connect pins T and R. SLT PTModular T-Adaptor
![](/img/blank.gif)
2.6 Connecting Doorphones and Door Openers 58 Installation Manual 2.6 Connecting Doorphones and Door Openers 2.6.1 Connecting Doorphones and Door Openers Up to 4 doorphones (KX-T30865) and 4 door openers (user-supplied) can be installed. Maximum Cabling Distance Door opener current limit: 30 V DC/30 V AC, 3 A maximum Installing the Doorphone (KX-T30865) 1.Loosen and remove the screw at the bottom of the case to separate the doorphone into 2 halves. 2.Pass the wires through the hole in the base cover, and attach the base cover to a wall using 2 screws. Cable Max. Distance 26 AWG: 70 m (230 ft) 24 AWG: 110 m (360 ft) 22 AWG: 150 m (492 ft) CAT 5: 110 m (360 ft) Cable Max. Distance 22 AWG: 150 m (492 ft)Doorphone Door Opener P a na so n ic Screw Screw To the Terminal Box
![](/img/blank.gif)
2.6 Connecting Doorphones and Door Openers Installation Manual 59 Note 2 kinds of screws are included with the KX-T30865. Please choose the appropriate screws for your wall type. 3.Connect the wires to the screws located in the front cover. 4.Re-attach the 2 halves and re-insert and tighten the screw.: when a doorphone plate has been fixed to the wall : when you wish to install the doorphone directly to the wall To the Terminal Box
![](/img/blank.gif)
2.6 Connecting Doorphones and Door Openers 60 Installation Manual Connecting Doorphones (KX-T30865) 1.Connect the Doorphone Card to the terminal boxes using 4-conductor wiring and modular connectors. 2.Connect the wires of doorphones 1 and 3 to the red and green screws on the appropriate terminal box. 3.Connect the wires of doorphones 2 and 4 to the yellow and black screws on the appropriate terminal box. PanasonicPanasonicPanasonicPanasonic Yellow RedBlack Green 4-conductor wiring is required. 4-conductor wiring is required. Doorphone 1 Doorphone 2 Yellow RedBlack Green Doorphone 3 Doorphone 4 View of Doorphone Connector Jack Doorphone 2 Doorphone 3 Doorphone 1Doorphone 4 Terminal Box Terminal Box PanasonicPanasonicPanasonicPanasonic