Electronic Modular Switching System
MODEL 
KX-T206E
Please read this manual before connecting the
Electronic Modular Switching System.
ELECTRONICMODULARSWITCHINGSYSTEM
P
O
W
E
R 

Page 2

Thank you for purchasing the Panasonic Model
KX-T206E, Electronic Modular Switching System.
Description
Electronic Modular Switching System
Proprietary telephone with display
Proprietary telephone
Proprietary telephone
DISA/FAX Detect Card
Doorphone Model No.
KX-T206E
KX-T7130E
KX-T7020E
KX-T7050E
KX-T20691E
KX-T30865E
System Component
Notes• In this Installation Manual, the suffix “E” of each model number is
omitted.
• A proprietary telephone is abbreviated as “PT”.
• A single line telephone is...

Page 3

3
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY.
This appliance is supplied with a moulded three pin mains plug for your safety and convenience.
A 5 amp fuse is fitted in this plug.
Should the fuse need to be replaced please ensure that the replacement fuse has a rating of
5 amps and that it is approved by ASTA or BSI to BS1362.
Check for the ASTA mark           or the BSI mark          on the body of the fuse.
If the plug contains a removable fuse cover you must ensure that it is refitted...

Page 4

4
Important Information
This equipment should be used on PSTN lines requiring 2-wire Loop calling unguarded clearing
with Loop Disconnect or DTMF address signalling.
The equipment must be connected to direct extension lines and a payphone should not be
connected as an extension.
Operation in Power Failure
In the event of a power failure, CO2 is connected to extension 22 automatically.
• Set the Dialling Mode (Tone or Pulse) of your telephone, according to the CO line.
• 999 and 112 can be dialled on the...

Page 5

5
Precaution
• Keep the unit away from heating appliances and electrical noise generating devices such as
fluorescent lamps, motors and television.  These noise sources can interfere with the perform-
ance of the Electronic Modular Switching System.
• This unit should be kept free of dust, moisture, high temperature (more than 40˚C/104˚F) and
vibration, and should not be exposed to direct sunlight.
• Never attempt to insert wires, pins, etc. into the vents or other holes of this unit.
• If there is any...

Page 6

6Specifications....................................................................................................................... 7
Before Installation............................................................................................................... 8
Unpacking............................................................................................................................ 9
Name and...

Page 7

7
Specifications
General Descriptions
1. Capacity .................................... CO line 2
Extension 6
2. Control Method ......................... Stored Program CPU: 8 bits CPU
         Control ROM: 64 KB, Control RAM: 8 KB
3. Switching Method ..................... Space Division CMOS Crosspoint Switch
4. Power Supplies ......................... Primary AC 110–240 V, 50/60 Hz
Secondary Circuit Volt: +5V, +15 V, +30 V
Power Failure CO 2 assigned to extension 22
5. Dialling Outward Dial Pulse 10...

Page 8

8
Before Installation
Please read the following notes concerning installation and connection before installing the
system.
Safety Installation Instructions
When installing telephone wiring, basic safety precautions should always be followed to reduce the risk
of fire, electric shock and injury to persons, including the following:
1. Never install telephone wiring during a lightning storm.
2. Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
3....

Page 9

9
Unpacking
• Main Unit ............................. one
• AC Cord ............................... one• Screw and Washer ................ three
• 4-pin Plug ............................. eight
P
O
W
E
R
ELECTRONICMODULARSWITCHINGSYSTEMAC Inlet
Power Indicator
Inside View of the Main Unit
Ground Terminal
Overview of the Main Unit
Name and Location
Doorphone Jack CO 4-pin Jack Extension 4-pin Jacks Door Opener Connector
Cable Holders
Notes
• Doorphone Jack and Door Opener Connector are at SELV.
• CO Line...

Page 10

101. Loosen the screw.
2. Slide the cover in the direction of the
arrow while pressing the marked
position.
Opening Front Cover
Frame Ground Connection
To Earth
POWERELECTRONICMODULARSWITCHINGSYSTEM
IMPORTANT!!!
Connect the frame of the main unit to earth.
Templet
Wall Mounting
1. Place the templet (on page 39) on the wall to
mark the three screw positions.
2. Install the three screws and washers (included)
into the wall.
3. Hook the main unit on the screw heads.
screw
POWER...