Before attempting to connect, operate or adjust this product, please read these instructions completely and save this manual for future use. Model AK-HTF900P Interface Adapter
2 FCC Note: This device complies with Part 15 of the FCC Rules. To assure continued compliance follow the attached instal- lation instructions and do not make any unauthorized modifications. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are de- signed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equip- ment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 1 is the safety information.CAUTION CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL. RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and main- tenance (servicing) instructions in the literature accompanying the appliance. CAUTION: TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE, USE THE RECOM- MENDED ACCESSORIES ONLY. WARNING: TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.This class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. For CANADA 12 Volt Class II Power Supply Only. (For Example: AW-PS505P) For Your Safety
3 Contents For Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Precautions for Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Controls and their Functions _Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 _Rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 How To Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Appearance and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Outline ≥This unit is able to separate multiple data (camera control data and swivel stand control data) transmitted from the camera controller (AK-HRP900P), and to output the control information to the multi-purpose camera (AK-HC900P) and the swivel stand (AW- PH300A, etc.). ≥The distance between this unit and the camera is 33 ft (10m) max. Precautions for Use ≥We recommend that the AC adapter AW-PS505P is used for power supply. ≥Handle the unit with care. If dropped or given a strong shock, it may cause a trouble or accident. ≥Use the unit in a temperature range of 32oF to 104oF (0oC to + 40oC). If used at a temperature below 32oF or higher than 104oF, it may cause bad influences to the component parts. ≥Turn off the power before connecting or disconnecting the cable. When connecting or disconnecting the cable, be sure to turn off the power switch of the unit beforehand. ≥Avoid using the unit outdoors. ≥Install the unit 3.3 ft (1 m) away from the monitor. ≥Maintenance Pull out the power cord plug and clean the unit with dry cloth. If it is hard to clean, moisten the cloth with a diluted neutral detergent solution and squeeze it well and lightly wipe the unit. ≥Do not use volatile solvents such as benzene or thinner. ≥When using a chemical mop, carefully read the instructions. Precautions
4 _Front panel POWEROFF ON Interface Adapter 1 2 1Power indication LED [POWER] When the power control switch 2is ON, it is lighted green. With the power control switch 2set to OFF, it goes out. 2Power control switch [POWER ON/OFF] When this switch is set to ON, this unit and the camera connected to it are turned on. With the switch set to OFF, both of the unit and the camera are tuned off. Controls and their Functions
3Camera connector [CAMERA I/F] Connected to the camera (AK-HC900P) with the attached multi-cable. 4Swivel stand control signal output connector [PAN/TILT CONTROL OUT] Connected to the swivel stand. 5Control data input connector [DATA IN] Used to input the data multiplexed by the camera controller (AK-HRP900P). 5 CAMERA CND ATA I NBEAKER DC 12V IN PAN/TILT CONTROL OUT 34 5 76 _Rear panel 1 7 2 3 4 5 68 9 10 11 12 13 14 151 7 2 3 4 5 68 9 10 11 12 13 14 15 1 7 2 3 4 5 68 9 10 11 12 13 14 15 Controls and their Functions Signal NC NC NC NC DC 12V Frame GND TXD (H) Pin No 8 9 10 11 12 13 14 15 Signal NC NC NC NC DC GND TXD (C) RXD (H) RXD (C) Pin No 1 2 3 4 5 6 7 TXD:Data from camera to remote controller.RXD:Data from remote controller to camera. Pin No 1 2 3 4 5 6 7 Signal NC NC NC NC NC Frame GND TXD (H) Pin No 8 9 10 11 12 13 14 15 Signal NC NC NC NC NC TXD (C) RXD (H) RXD (C)
Signal GND ––– 12V 6 6Breaker [BREAKER] DC power breaker. The breaker operates to cut off the power in case of over-current. 7DC12V input connector [DC 12V IN] (XLR4-pin) Connects the AC adapter. We recommend that the AW-PS505P (option) is used. 1 234 Controls and their Functions Pin No 1 2, 3 4
How To Connect 7 O I BREAKER ZOOM/ FOCUS SDI OUT1 2 1 /F G/L I N Pb OUT Pr / SDI OUTY/ VIDEO OUT 1394CONTROL IN IP/RPDC12V IN CAMERA I/F LENSE I/F ND/EXT SDI IN CSOP O I O I POWERON OFFSD CARDOPERATE ALARMSCENE MODEPRE CAM BAR TESTUSER1 USER2Camera Controller TA L LY MENU ON MENU SPEED ZOOMTELE WIDEFA R NEARFOCUS12345PRESETCC FLTER3200CROSS6300 4300ND FLTER11/321/16 1/4SHUTTER OFFSYNCROSTEPGAIN0S1 S2 S39dB 18dB AUTO WHITE BLACKGAINBLACK AUTO M-PEDIRISCHECK Interface adapter AK-HTF900P ≥Make the connections with all the units turned off. ≥We recommend that the AW-PS505P (option) is used as AC adapter ≥Use a swivel stand, AW-PH300A, AW-PH500, AW-PH600, and an adapter suited for the swivel stand. Remote (zoom/focus control) cable Swivel stand controllerAW-RP301 Swivel stand AW-PH300A Multi-purpose digital camera AK-HC900P Multi-cable (17 ft) AK-HDMLTCA05 Camera controller AK-HRP900PHD monitor AC adapter AW-PS505P DDC power cable Coaxial cable (5C-FB) HD-SDI AC adapter AW-PS301 AC adapter AW-PS505P Swivel stand control is possible for AW- PH500/PH600 as well. AC adapter AW-PS300Multi-cable (17ft) AK-HDMLTCA05 Trans- mission Remote control spec. lens
Appearance and Dimensions 8 ( ): mm POWEROFF ON Interface Adapter CAMERA CNDATA INBEAKER DC 12V IN PAN/TILT CONTROL OUT 8-3/16z (206.5) 9-7/8z (250) 2-1/8z (42.4) 7/16z (10.3)
Specifications 9 Swivel control output: Switch function: Cable max. extension distance: Operating temperature: Dimensions: Weight: Finish:Control signal (RJ-45 8P modular jack) Power control 33 ft (10m) 32oF to 104oF (0oC to +40oC) 8-3/16(W)k2-1/8(H)k9-7/8(D) inch (206.5k52.7k250 mm) Approx. 4.18 lbs (1.9 kg) AV ivory coating (Munsell 7.9Y 6.8/0.8 approx. color) 1is the safety information. Power supply: DC +12V (XLR 4-pin connector) Power consumption: 25 W (with camera connected) Weight and dimensions shown are approximate. Specifications are subject to change without notice.