Home > Panasonic > Camera Accessories > Panasonic Interface Adapter Ak Htf900p Operating Instructions

Panasonic Interface Adapter Ak Htf900p Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Interface Adapter Ak Htf900p Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Before attempting to connect, operate or adjust this product, 
    please read these instructions completely and save this manual for future use.
    Model AK-HTF900P
     
    Interface Adapter 
    						
    							2
    FCC Note:
    This device complies with Part 15 of the
    FCC Rules. To assure continued
    compliance follow the attached instal-
    lation instructions and do not make any
    unauthorized modifications.
    This equipment has been tested and
    found to comply with the limits for a Class
    A digital device, pursuant to Part 15 of
    the FCC Rules. These limits are de-
    signed to provide reasonable protection
    against harmful interference when the
    equipment is operated in a commercial
    environment. This equipment generates,
    uses, and can radiate radio frequency
    energy and, if not installed and used in
    accordance with the instruction manual,
    may cause harmful interference to radio
    communications. Operation of this equip-
    ment in a residential area is likely to
    cause harmful interference in which case
    the user will be required to correct the
    interference at his own expense.
    1 is the safety information.CAUTION
    CAUTION:
    TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
    COVER (OR BACK).
    NO USER SERVICEABLE PARTS INSIDE.
    REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL.
    RISK OF ELECTRIC SHOCK
    DO NOT OPEN
    The lightning flash with
    arrowhead symbol, within an
    equilateral triangle, is intended to
    alert the user to the presence of
    uninsulated “dangerous voltage”
    within the product’s enclosure
    that may be of sufficient
    magnitude to constitute a risk of
    electric shock to persons.
    The exclamation point within an
    equilateral triangle is intended to
    alert the user to the presence of
    important operating and main-
    tenance (servicing) instructions
    in the literature accompanying
    the appliance.
    CAUTION:
    TO REDUCE THE RISK OF FIRE OR
    SHOCK HAZARD AND ANNOYING
    INTERFERENCE, USE THE RECOM-
    MENDED ACCESSORIES ONLY.
    WARNING:
    TO REDUCE THE RISK OF FIRE OR
    SHOCK HAZARD, DO NOT EXPOSE
    THIS EQUIPMENT TO RAIN OR
    MOISTURE.This class A digital apparatus complies
    with Canadian ICES-003.
    Cet appareil numérique de la classe A
    est conforme à la norme NMB-003 du
    Canada.
    For CANADA
    12 Volt Class II Power Supply Only.
    (For Example: AW-PS505P)
    For Your Safety 
    						
    							3
    Contents
    For Your Safety  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
    Outline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
    Precautions for Use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
    Controls and their Functions
    _Front panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
    _Rear panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
    How To Connect  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
    Appearance and Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
    Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
    Outline
    ≥This unit is able to separate multiple data (camera control data and swivel stand control
    data) transmitted from the camera controller (AK-HRP900P), and to output the control
    information to the multi-purpose camera (AK-HC900P) and the swivel stand (AW-
    PH300A, etc.).
    ≥The distance between this unit and the camera is 33 ft (10m) max.
    Precautions for Use
    ≥We recommend that the AC adapter AW-PS505P is used for power supply.
    ≥Handle the unit with care.
    If dropped or given a strong shock, it may cause a trouble or accident.
    ≥Use the unit in a temperature range of 32oF to 104oF (0oC to + 40oC).
    If used at a temperature below 32oF or higher than 104oF, it may cause bad influences to
    the component parts.
    ≥Turn off the power before connecting or disconnecting the cable.
    When connecting or disconnecting the cable, be sure to turn off the power switch of the
    unit beforehand.
    ≥Avoid using the unit outdoors.
    ≥Install the unit 3.3 ft (1 m) away from the monitor.
    ≥Maintenance
    Pull out the power cord plug and clean the unit with dry cloth.  If it is hard to clean,
    moisten the cloth with a diluted neutral detergent solution and squeeze it well and lightly
    wipe the unit.
    ≥Do not use volatile solvents such as benzene or thinner.
    ≥When using a chemical mop, carefully read the instructions.
    Precautions 
    						
    							4 _Front panel
    POWEROFF ON
    Interface  Adapter
    1
    2
    1Power indication LED [POWER]
    When the power control switch 2is ON, it is lighted green.  With the power control
    switch 2set to OFF, it goes out.
    2Power control switch [POWER ON/OFF]
    When this switch is set to ON, this unit and the camera connected to it are turned on.
    With the switch set to OFF, both of the unit and the camera are tuned off.
    Controls and their Functions 
    						
    							3Camera connector [CAMERA I/F]
    Connected to the camera (AK-HC900P) with the attached multi-cable.
    4Swivel stand control signal output connector [PAN/TILT CONTROL OUT]
    Connected to the swivel stand.
    5Control data input connector [DATA IN]
    Used to input the data multiplexed by the camera controller (AK-HRP900P).
    5
    CAMERA
    CND ATA I NBEAKER
    DC 12V
    IN
    PAN/TILT
    CONTROL  OUT
    34 5 76
    _Rear panel
    1 7
    2 3 4 5 68 9 10 11 12 13 14 151 7
    2 3 4 5 68 9 10 11 12 13 14 15
    1 7
    2 3 4 5 68 9 10 11 12 13 14 15
    Controls and their Functions
    Signal
    NC
    NC
    NC
    NC
    DC 12V
    Frame GND
    TXD (H)
    Pin No
    8
    9
    10
    11
    12
    13
    14
    15
    Signal
    NC
    NC
    NC
    NC
    DC GND
    TXD (C)
    RXD (H)
    RXD (C)
    Pin No
    1
    2
    3
    4
    5
    6
    7
    TXD:Data from camera to remote controller.RXD:Data from remote controller to camera.
    Pin No
    1
    2
    3
    4
    5
    6
    7
    Signal
    NC
    NC
    NC
    NC
    NC
    Frame GND
    TXD (H)
    Pin No
    8
    9
    10
    11
    12
    13
    14
    15
    Signal
    NC
    NC
    NC
    NC
    NC
    TXD (C)
    RXD (H)
    RXD (C) 
    						
    							Signal
    GND
    –––
    12V
    6
    6Breaker [BREAKER]
    DC power breaker.  The breaker operates to cut off the power in case of over-current.
    7DC12V input connector [DC 12V IN] (XLR4-pin)
    Connects the AC adapter.  We recommend that the AW-PS505P (option) is used.
    1
    234
    Controls and their Functions
    Pin No
    1
    2, 3
    4 
    						
    							How To Connect
    7
    O    I
    BREAKER
    ZOOM/
    FOCUS
    SDI OUT1
    2
    1
    /F
    G/L I N Pb  OUT Pr / SDI
    OUTY/ VIDEO
    OUT
    1394CONTROL IN
    IP/RPDC12V
    IN
    CAMERA I/F
    LENSE I/F
    ND/EXT SDI
    IN
    CSOP
    O    I
    O    I
    POWERON OFFSD  CARDOPERATE
    ALARMSCENE
    MODEPRE
    CAM BAR TESTUSER1 USER2Camera  Controller
    TA L LY
    MENU
    ON
    MENU
    SPEED ZOOMTELE
    WIDEFA R
    NEARFOCUS12345PRESETCC  FLTER3200CROSS6300 4300ND  FLTER11/321/16 1/4SHUTTER
    OFFSYNCROSTEPGAIN0S1 S2
    S39dB 18dB
    AUTO
    WHITE BLACKGAINBLACK
    AUTO M-PEDIRISCHECK
    Interface adapter
    AK-HTF900P
    ≥Make the connections with all the units turned off.
    ≥We recommend that the AW-PS505P (option) is used as AC adapter 
    ≥Use a swivel stand, AW-PH300A, AW-PH500, AW-PH600, and an adapter suited for the
    swivel stand.
    Remote
    (zoom/focus
    control) cable
    Swivel stand controllerAW-RP301
    Swivel stand
    AW-PH300A
    Multi-purpose digital camera
    AK-HC900P
    Multi-cable (17 ft)
    AK-HDMLTCA05
    Camera controller
    AK-HRP900PHD monitor
    AC adapter
    AW-PS505P
    DDC
    power
    cable Coaxial cable (5C-FB) HD-SDI
    AC adapter
    AW-PS301 AC adapter
    AW-PS505P
    Swivel stand control is
    possible for AW-
    PH500/PH600 as well.
    AC adapter
    AW-PS300Multi-cable (17ft)
    AK-HDMLTCA05
    Trans-
    mission
    Remote
    control
    spec. lens 
    						
    							Appearance and Dimensions
    8
    (   ): mm
    POWEROFF ON
    Interface  Adapter
    CAMERA
    CNDATA INBEAKER
    DC 12V
    IN
    PAN/TILT
    CONTROL  OUT
    8-3/16z (206.5)
    9-7/8z (250)
    2-1/8z
    (42.4) 7/16z 
    (10.3) 
    						
    							Specifications
    9
    Swivel control output:
    Switch function:
    Cable max. extension distance:
    Operating temperature:
    Dimensions:
    Weight:
    Finish:Control signal (RJ-45 8P modular jack)
    Power control
    33 ft (10m)
    32oF to 104oF (0oC to +40oC)
    8-3/16(W)k2-1/8(H)k9-7/8(D) inch
    (206.5k52.7k250 mm)
    Approx. 4.18 lbs (1.9 kg)
    AV ivory coating (Munsell 7.9Y 6.8/0.8 approx. color)
    1is the safety information.
    Power supply: DC  +12V (XLR 4-pin connector)
    Power consumption: 25 W (with camera connected)
    Weight and dimensions shown are approximate.
    Specifications are subject to change without notice. 
    						
    All Panasonic manuals Comments (0)