Page 51
51 Example of system configuration Convertible camera MONITOR1 MonitorMonitor Cable provided with AW-CB400 Monitor switching AW-RC400 Cable Compensation Unit AW-PS505 AC adaptor Pan/Tilt Control Panel AW-RP400 Remote Operation Panel AW-CB400 Headset Headset MONITOR2 Pan/tilt head and camera control Indoor Pan/Tilt Head AW-PH400 Composite video or component video signals To switcher, monitor Genlock signals G/L AW-PS301 AC adaptor
Page 52
52 Operating procedures $Turning on the power 1 When using one AW-RP400, set its EXT CONT [M/S] switch to the [M] positi\ on. When two AW-RP400 units are used, set the EXT CONT [M/S] switch on the A\ W-RP400 to which the pan/tilt head is connected to the [M] (master) position and the switch on the AW-RP400 \ to which the pan/tilt head is not connected to the [S] (slave) position. \b Turn on the power. Follow the sequence below to turn on the power when one AW-RP400 is goin\ g to be used: Set the power...
Page 53
53 Operating procedures 6To set the counterclockwise limit of the roll unit, use the ROTATION swi\ tch to rotate the roll unit as far as the limit in the counterclockwise direction which is to be set. While holding down the MENU/LIMIT button, press the PRESET MEMORY button\ [25]. Once the limit is set, the lamp of the PRESET MEMORY button [45] will li\ ght. To release the setting, press the PRESET MEMORY button [25] again while \ holding down the MENU/LIMIT button. Once the setting is released, the lamp...
Page 54
54 Operating procedures $Genlock adjustments for the respective cameras For details on the genlock adjustments, refer to the operating instructi\ ons of the AW-CB400 remote operation panel or WV-CB700A remote control box. $Video adjustments for the cameras Adjust the total pedestal (black level), white balance, black balance,\ etc. of the cameras. For details on the camera adjustments, refer to the operating instructio\ ns of the AW-CB400 remote operation panel or WV-CB700A remote control box....
Page 55
55 Operating procedures 3Press the START POINT button. The lamps of the buttons among TRACING MEMORY buttons 1 to 10 where data\ can be registered now light. ≥ The lamps of the buttons with numbers exceeding the number of memories s\ et by the MEMORY LENGTH menu setting do not light. ≥ If the lamp of any button among the number of memories in which data can\ be set is off, it means that data has already been registered in the button. When registering data in such a button, d\ elete the existing data in...
Page 56
56 Operating procedures 1Select the pan/tilt head system using one of the CONTROL SELECT buttons.\ When using the AW-CB400 for camera control, select the same number for t\ he AW-CB400. \b Press the button corresponding to the tracing memory whose registered da\ ta is to be changed, and call the start position. 3 Press the RESTORE button. The pan/tilt head system starts the operation registered in the tracing \ memory, and the lamp of the STOP button flashes. As when the data was registered, the PRESET...
Page 57
57 Operating procedures 1Select the pan/tilt head system using one of the CONTROL SELECT buttons.\ \b When the button corresponding to the registered preset memory data is pr\ essed, the pan/tilt head system is set to the registered status. Playing the preset memory data
Page 58
58 Cable specifications When an IAS, WAS or VAS lens (analog drive) made by Canon is used Connect to the LENS I/F2 connector on pan/tilt head. ❈The cable lengths are approximate. Ensure that their lengths are approp\ riate for the actual system used. Connector: 10136-3000VE made by Sumitomo 3M Case: 10336-52F0-008 made by Sumitomo 3M Connector: SR30-10PE-6P made by Hirose Electric Connect to the FOCUS connector on lens.Cable length: At least 800 mm or so Connector: R01-01P9-8M made by Tajimi Musen...
Page 59
59 Cable specifications When an IASD, WASD or VASD lens (digital drive) made by Canon is used Connect to the LENS I/F2 connector on pan/tilt head. ❈The cable lengths are approximate. Ensure that their lengths are approp\ riate for the actual system used. Connector: 10136-3000VE made by Sumitomo 3M Case: 10336-52F0-008 made by Sumitomo 3M Connector: HR25-9P-20P made by Hirose Electric Connect to the ZOOM/FOCUS connector on lens. Cable length: At least 800 mm or so Connector: HR10A-10J-12P made by Hirose...
Page 60
60 Cable specifications When an RD lens made by Fujinon is used Connect to the LENS I/F2 connector on pan/tilt head. ❈The cable lengths are approximate. Ensure that their lengths are approp\ riate for the actual system used. Connector: 10136-3000VE made by Sumitomo 3M Case: 10336-52F0-008 made by Sumitomo 3M Connector: HR10A-10P-12P made by Hirose Electric Connect to the FOCUS connector on lens.Cable length: At least 800 mm or so Connector: HR10A-10P-12P made by Hirose Electric Connect to the ZOOM...