Page 11

-9-
SW 2 SW 1 SW 3
SW 2 SW 1
SW 3
DESKTOP
HANGING
CONTACT/RS232CSERIAL
nBefore Installing
Before installing the pan/tilt head, be sure to make the
following settings and changes.
lSetting the Mounting Direction Switches
and Setting Others in Case of Using
Contact Type Controller, RS232C
To mount the pan/tilt head upright, or to control the
pan/tilt head with a contact type controller or RS-232C,
make the following settings.
(This is unnecessary in case of controlling a suspend-
ed pan/tilt head from a...

Page 12

-10-
ON
OFF
lSetting the Cable Compensation Circuit
If the pan/tilt head is connected to the controller with
coaxial cables (5C-2V), the maximum allowable dis-
tance between them is 500 meters.  If the cable length
between them is more than 300 meters, however, set
the cable compensation circuit switch to the ON posi-
tion as described below.
• Remove the 4 screws from Control Connector Panel !2
and pull out the panel toward yourself.
• Set the switch on the PCB on the back of the panel to
the ON...

Page 13

-11-
ñ]wbhRlN^pl
RlN^pl
(t)
(t)
• Turn the panel 180°, and place it back in position.
• Fasten the panel with the screws.
nMounting the Pan/tilt Head
Observe the following instructions for mounting the
pan/tilt head.
Failure to observe these instructions could cause the
pan/tilt head to come off or drop, possibly resulting in
an accident.
• To mount the pan/tilt head, use the 4 mounting holes
and fasten the head securely.
• Have M6 hex bolts ready for mounting the head.
• The hex bolts must be long...

Page 14

-12-
Lens lock ring knob
lMounting a Camera
nMounting a CameralMounting a Lens• Turn the lens lock ring knob fully counterclockwise.
• Remove the lens mount cap if any.
• Mount the lens  with the lens positioning pin up.
• Turn the lens lock ring knob clockwise to securely fas-
ten the lens.
• Hold the camera and place it on Camera Mounting
Plate e.
• Hold the camera and insert Camera Guide Pin rinto
the guide hole in the camera.
• Hold the camera and tighten Camera Mounting Screw
tto securely fasten the...

Page 15

-13-
nConnecting Camera Connector Panel
Connect the camera and lens control cables.
q
we
FA
EB
DC
NDVOi
ND ^ [
EXTVOi
EXT ^ [ CVCC (+15V)
CGND
(As viewed from cable end)
qCAMERA I/F
Control connector for camera WV-E550 or AW-E560
Connect it to the camera’s REMOTE connector with the
camera cable AW-CA20T15 (option).
wND/EXT
Control connector for motor-driven lens unit’s ND filter
and lens extender
In case of using a motor-driven lens unit having ND fil-
ters and lens extender function, connect it to that...

Page 16

CAMERA
CONTROL OUTCAMERA
CONTROL IN VIDEO OUTPAM/TILT
CONTROL OUTPAM/TILT
CONTROL IN
S-VIDEO OUT VIDEO
IN
G/L
OUTG/L
IN
CAMERA
CONTROL OUTVIDEO OUTPAM/TILT
CONTROL OUT
S-VIDEO OUT VIDEO
IN
G/L
OUT
CAMERA
CONTROL OUTVIDEO OUTPAM/TILT
CONTROL OUT
S-VIDEO OUT VIDEO
IN
G/L
OUT
CAMERA
CONTROL OUTVIDEO OUTPAM/TILT
CONTROL OUT
S-VIDEO OUT VIDEO
IN
G/L
OUT
CAMERA
CONTROL OUTVIDEO OUTPAM/TILT
CONTROL OUT
S-VIDEO OUT VIDEO
IN
G/L
OUT
4
3
2
1 5
DC12V  IN
TO CAMERA PAM/TILT HEAD
TO CONTROL PANELPREVIEW OUT
SEE...

Page 17

-15-
n
Connecting the Pan/tilt Head AC AdapterConnect the Pan/tilt Head AC Adapter AW-PS300.
AC IN
  OPTIONSW
CONTROL OUT  OPTIONSW
CONTROL IN  LAMP
CONTROLDC 15V
   OUTOP C          S
+        –LAMP AC OUT(                 )
MIN  250W
MAX 500W
[ͼc
¨© ·
P/T CONTROL IN
(CONTACT/RS-232C)
Wiring q
Wiring w
Wiring e
about 1 cm
Pan/tilt Head AC Adaptor  AW-PS300Terminal board
qG/L IN
Genlock signal input connector
Connect it to the G/L OUT connector on the Multiport
Hub (AW-HB505) or Control Panel (AW-RP501)...

Page 18

-16-
Make sure that the positive (+) end and negative (-)
end of the wire are connected to the same signs on the
terminal.
Use a DC cable with a nominal cross section of 1.25
mm
2or more that meets the UL specifications.
Terminal Board LAMP CONTROL (Wire w)
Connect it only in case of supplying power from LAMP
AC OUT on the Pan/tilt Head AC Adapter AW-PS300 to
the halogen lamp.
Connect it to LAMP CONTROL on the Pan/tilt Head AC
Adapter.
The symbols C and S of the wire must match the same
symbols on the...

Page 19

lConnecting Other Controllers
P/T CONTROL IN (CONTACT/RS-232C)
Connect it in case of controlling the pan/tilt head with a
contact type controller, or via an RS-232C.  Have a
cable ready which meets the signal requirements
specified in the pin assignment table below.  TThe
cable must have a nominal cross section of 0.3 mm
2or
more and meets the UL specifications.
The applicable connector is a bellows type 28-pin
(1.27-mm pitch) plug.
Note:When using a contact type controller or an RS-
232C, the switches...

Page 20

-18-
Switch and PRESET-6 Switch for 5 seconds or more.
• When the LED for PRESET-5 Switch lights to indicate
that the left limit has been set, release the switches.
• Check on the control panel that the left limit has been
correctly set.
lSetting the Operating Range Right Limit• Turn the camera to the desired right limit from the con-
trol panel.
• Keep the MEMORY Switch on the control panel
depressed, then simultaneously press PRESET-4
Switch and PRESET-9 Switch for 5 seconds or more.
• When the LED for...