-19- • Changing Switch Settings on Pan/tilt Head qRemove the cover from the pan/tilt head. * Be careful of the Tally Indicator wire.wShift the mounting direction switches (SW1, SW2) on the pan/tilt head depending on whether the head is suspended from the ceiling or mounted on the floor. They are originally set for suspended installation. * Do not shift SW3, which is originally set to If SW3 is shifted from the original position, no operations can be controlled from the control panel.ePlace the cover back on the pan/tilt head. * Be sure not to trap the wires. • If the pan/tilt head is connected to the control panel with a cable longer than 300 meters, set the cable compensation switch on the pan/tilt head to the ON position in advance. If the distance between the pan/tilt head and the control panel is shorter than 300 meters, keep the switch in the original position (OFF). For details on shifting the switch, refer to the figure below or the Operating Instructions for Pan/tilt Head. SW 2 SW 1 SW 3 SW 2 SW 1 DESKTOP HANGING Tally Indicator
-20- • Shifting Cable Compensation Switch on Pan/tilt Head If the distance from the control panel to the pan/tilt head is longer than 300 meters, set the cable compensation switch to the ON position by observing the following procedure. qRemove the controller connection panel from the pan/tilt head. * Be careful of the wires. wShift the cable compensation switch on the inner side of the controller connection panel of the pan/tilt head to the ON position. ePlace the controller connection panel back on the pan/tilt head. ON OFF n Lens Mounting• Turn the lens lock ring knob fully counterclockwise. • If the lens mount has a cap, remove the cap. • With the lens positioning pin up, mount the lens. • Turn the lens lock ring knob clockwise till the lens is securely fastened. Lens lock ring knob
-21- CONNECTIONS• Before making any connection, switch off all the com- ponents of the system. • Use the control panel AC Adaptor AW-PS301 (optional) and Pan/tilt Head AC Adaptor AW-PS300 (optional). • Use the pan/tilt AW-PH300 and the Color Video Camera WV-E550 or AW-E560. To connect the pan/tilt head to the camera, the Camera Cable AW-CA20T15 (optional) is necessary. • Locally purchase a DC cable with a nominal cross sec- tion of 1.25 mm 2or larger that meets the UL specifica- tions, and connect the Pan/tilt Head AW-PH300 to the Pan/tilt Head AC Adaptor AW-PS300 with that cable. The maximum distance between the pan/tilt head and pan/tilt head AC adapter is 30 m. • Connect the AC Adaptor AW-PS301 to the control panel and clamp the DC cable of the AC adaptor to the cord clamp on the control panel. • Connect the Pan/tilt Head AW-PH300 to the Color Video Camera WV-E550 or WV-E560 with the Camera Cable AW-CA20T15. DC Cord Cord Clamper Control Panel AC Adaptor AW-PS301
-22- ITEM(AWC) UP(ABC)PAGEDOWN (BAR)IRIS G/L INVIDEO OUT ZOOM/FOCUS REMOTEVD VIDEO/RGB VBS/HD 75ON OFF CONTROL EXT DC INSEE MANUALCAUTION • Connect the iris control cable of the motor-driven zoom lens to the camera and the remote (zoom/focus control) cable to the pan/tilt head. If the remote (zoom/focus control) cable of the motor-driven zoom lens is con- nected to the camera, the lens cannot be controlled.• Connect the control panel to the pan/tilt head with the three coaxial cables (video signal, G/L signal, camera control signal) and one 10BASE-T straight cable (pan/tilt head control signal). The maximum distance between the control panel and pan/tilt head is 500 meters for coaxial cables 5C-2V and 10BASE-T cable (UTP category 5 or equivalent). • For further details on connecting the individual devices, refer to their operating instruction manuals. To Lens Interface ConnectorTo Iris Connector Iris Control Cable Remote (Zoom/Focus Control) Cable
-23- AC IN LAMP AC OUT MIN 250W MAX 500W OPTION SW CONTROL OUTOPTION SW CONTROL INLAMP CONTROL OP SC DC 15V OUT- + TALLY HOT DC12V IN AUX CONTROL IN VIDEO IN OUT G/L OUTVIDEO OUT 1 VIDEO OUT 2 CONTROL CONTROL OUTPAN/TILT CAMERA TO CAMERA PAN/TILT HEADG / L IN S-VIDEO OUT PAGEITEM(AWC) UP(ABC)DOWN (BAR) IRIS G/L IN VIDEO OUT ZOOM/FOCUS REMOTEVD VIDEO/RGB VBS/HD 75 ON OFF CONTROL EXT DC INSEE MANUAL CAUTION Connecting the control panel to Color Video Camera (WV-E550 or WV-E560), Pan/tilt Head (AW-PH300), and Pan/tilt Head AC Adapter (AW-PS300) Pan/tilt Head AW-PH300Color Video Camera WV-E550 or AW-E560To Servo Control Zoom Lens Camera Cable AW-CA20T15 AW-RP501 Pan/tilt Head AC Adaptor AW-PS300VIDEO OUT G/L THROUGH OUT G/L IN PAN/TILT CONTROL IRIS CONTROL ZOOM/FOCUS CONTROL CAMERA CONTROL GEN-LOCK VIDEO DC+15VS-VIDEO OUT
-24- SPEED FOUCUS PA N / T I LT ZOOM TELE WIDEFA R LEFT RIGHTUP DOWN NEAR DEFON OFF POWEROPERATE IRIS BAR CAMMODEGAIN AWC SCENE FILEABC AT W A B AUTO/AIWELC LOW MID MANUON SC H OFF HIGH AGC OFF 1 / 100SHUTTER ON OFF LAMPMEMORY ON OFF AUTO MANUON OFFON OFFON OFF ON OFFON OFF WIP EXT ND OPH / F 1 . 2 . 3 . 4 . G/L PHASE PRESET T.PED CABLE COMPHybrid Control Panel AW-RP501 2 1345 67891090¡ 180¡ 0¡ 270¡ LEVELTALLY YC S-VIDEO VIDEO VIDEO G/L G/L DC 15V OPTION SWITCH CONTROL CONTACT POWERON OFF Color Monitor WV-CM 1470 PUSH SYSTEM TALLY CAMERA CONTROL PAN/TILT CONTROL ZOOM/FOCUS CONTROL IRIS CONTROL LAMP CONTROL • Example of System Connection Camera Cable AW-CA20T15 Color Video Camera WV-E550 or AW-E560 Pan/tilt Head AC Adaptor AW-PS300 Hybrid Control Panel AW-RP501Signal Generator Control Panel AC Adaptor AW-PS301 Halogen LampServo Control Zoom LensColor Monitor (75Wtermination) Be sure to connect the zoom/focus control to the pan/tilt head, not to the camera Unnecessary if no halogen lamp is used. Unnecessary if no optional unit is connected. Optional Units Special Effect Generator and Switcher etc.
-25- OPERATING PROCEDURES1.Power Set the power switch on the pan/tilt head AC adapter to the ON position, then set Power ON/OFF Switch won the control panel to the ON position. 2. Pan/tilt Limiter Setting for Pan/tilt Head If there are obstacles around the pan/tilt head, set the limiters to limit the operating range (pan left and right ends, tilt up and down ends) of the pan/tilt head. Note:The switches on the pan/tilt head have been pre- set before shipment from the factory on the assumption that the pan/tilt head would be sus- pended from the ceiling. If the pan/tilt head is mounted on a board, for example, be sure to shift the mounting direction switches on the pan/tilt head. Unless this is done, pan/tilt directions will be reversed and pan/head operation limiter data can- not be properly stored in the memory. For details on shifting these switches, refer to INSTALLATION OF PAN/TILT HEAD at page 18 or the Operating Instructions for Pan/tilt Head. MEMORY PRESET 2 1345 678910 qLeft Panning Limiter Turn the pan/tilt head to the desired left panning limit with PAN/TILT Lever #8, keep MEMORY Switch @7 depressed, and simultaneously press buttons [1] and [6] of PRESET Switches @8for 5 seconds or more. When the desired limit has been set, button [5] of PRE- SET Switches @8lights. To reset the limit, keep the MEMORY switch @7 depressed, and simultaneously press buttons [1] and [6] of PRESET Switches @8again for 5 seconds or more. When the set limit is reset, button [10] of PRE- SET Switches @8lights. Up tilting limiterPreset position selection switch Left panning limiterLights on completion of setting. Preset memory switchLights on completion of resetting Down tilting limiterRight panning limiter
-26- wRight Panning Limiter Turn the pan/tilt head to the desired right panning limit with PAN/TILT Lever #8, keep MEMORY Switch @7 depressed, and simultaneously press buttons [4] and [9] of PRESET Switches @8for 5 seconds or more. When the desired limit has been set, button [5] of PRE- SET Switches @8lights. To reset the limit, keep the MEMORY Switch @7 depressed, and simultaneously press buttons [4] and [9] of PRESET Switches @8again for 5 seconds or more. When the set limit is reset, button [10] of PRE- SET Switches @8lights. eUp Tilting Limiter Turn the pan/tilt head to the desired up tilting limit with PAN/TILT Lever #8, keep MEMORY Switch @7 depressed, and simultaneously press buttons [2] and [3] of PRESET Switches @8for 5 seconds or more. When the desired limit has been set, button [5] of PRE- SET Switches @8lights. To reset the limit, keep the MEMORY switch @7 depressed, and simultaneously press buttons [2] and [3] of PRESET Switches @8again for 5 seconds or more. When the set limit is reset, button [10] of PRE- SET Switches @8lights.rDown Tilting Limiter Turn the pan/tilt head to the desired down tilting limit with PAN/TILT Lever #8, keep MEMORY Switch @7 depressed, and simultaneously press buttons [7] and [8] of PRESET Switches @8for 5 seconds or more. When the desired limit has been set, button [5] of PRE- SET Switches @8lights. To reset the limit, keep the MEMORY switch @7 depressed, and simultaneously press buttons [7] and [8] of PRESET Switches @8again for 5 seconds or more. When the set limit is reset, button [10] of PRE- SET Switches @8lights.
-27- 3. Cable Compensation Setting, Genlock and Total Pedestal Adjustment• Cable Compensation Signal degradation due to cable length between the con- trol panel and the pan/tilt head can be compensated for. qIf the cable length from the pan/tilt head to the control panel is longer than 300 meters, set the cable com- pensation switch on the pan/tilt head to the ON posi- tion. For details, refer to INSTALLATION OF PAN/TILT HEAD at page 18 or the Operating Instructions for Pan/tilt Head. wConnect a waveform monitor or a vectorscope to the VIDEO OUT connector $7on the control panel, set the MODE BAR/CAM Switch rto the BAR position, then observe the color bar signals. eAdjust the Y (luminance) signal level with CABLE COMP Y Control @0. then adjust the C (chrominance) signal level with CABLE COMP C Control @1. Repeat this until the video output of the control panel is adjust- ed as shown in the figure below. Note:Turning CABLE COMP Y Control @0changes not only the Y (luminance) signal level but also the video signal levels as a whole. GRAY YELLOW CYAN GREEN MAGENTA RED BLUE 100 90 80 70 60 50 40 30 20 10 0 –10 –20 –30 –40+69 +77 +56 +48 +38 +12 +7 –5 –16 –16+15 +28 +36 +20 –20 +20 –20+100 +100 +89 +77 +72 +46 IRE 75% 100% 1V[p-p] +100 +27 +27 -20 –13 –13 100 90 80 70 60 50 40 30 20 10 0 –10 –20 –30 –40IRE 75% 100% +20 –20+20 –20 +7.5 +7.5 -I WHITE +Q BLACK 1V[p-p] Color Monitor Color MonitorWaveform Monitor Waveform Monitor
-28- • Genlock AdjustmentTo use the camera in external sync mode, phase adjust- ment is necessary to match the phases with those of the other units and camera. No G/L adjustment is necessary in case of no genlock. • Horizontal Phase Adjustment qSet G/L PHASE ON/OFF Switch !5to the ON position. Note:When G/L PHASE ON/OFF Switch !5is set to the ON position, the sync phase of the camera changes to the settings of G/L PHASE H Control !8, G/L PHASE Coarse Switch !6, and G/L PHASE SC Control !7. Unless G/L phase adjustment is necessary, do not set G/L PHASE ON/OFF Switch !5to the ON position. wObserve the waveforms of the G/L signal input (black burst signal) and video signal output on a dual channel oscilloscope, and turn the G/L PHASE H control !8tomatch the horizontal phase as shown in the figure right. eSet G/L PHASE ON/OFF Switch !5back to the OFF position. ON SC H OFF G/L PHASE 90° 180° 0° 270° External genlock input signal (black burst signel) Video signal G/L PHASE H Control G/L PHASE ON/OFF Switch Waveform Monitor Vector ScopeColor Monitor (75Wtermination)