Home > Panasonic > Household Appliance > Panasonic Household Foot Massager Ep30102 Operating Instructions

Panasonic Household Foot Massager Ep30102 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Household Foot Massager Ep30102 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							No.	1	EN,	SP,	FR	 	Printed	in	China
    	 Impreso	en	China
    	 P9310301031	Imprimé	en	Chine
    Panasonic	Consumer
    Electronics	Company
    One	Panasonic	Way	1H-1
    Secaucus,	New	Jersey	07094
    1-800-338-055	for	questions	and	comments.
    www.panasonic.com/massage
    Panasonic	Canada	Inc.
    5770	Ambler	Drive
    Mississauga,	ON	L4W	T3
    905-64-5010
    www.panasonic.ca
       112007/12/19   18:05:58
    English	1
    Español	S1
    Français	F1
    Operating	Instructions
    Instrucciones	de	Uso
    Mode	d’emploi
    Household 	Foot 	Massager
    Masajeador 	de 	pie 	doméstico
    Masseur 	de 	pieds 	à 	domicile
    Model 	No./Nº 	de 	Modelo/Nº 	de 	modèle 	EP30102
    Before	operating	this	unit,	please	read	these	instructions	completely.
    Antes	de	utilizar	esta	unidad,	lea	compleatamente	estas	instrucciones	y	
    guárdelas	para	referencia	futura.
    Avant	d’utiliser	cet	appareil,	nous	vous	recommandons	de	lire	
    l’ensemble	de	ces	instructions	et	de	les	ranger	dans	un	endroit	
    accessible	pour	une	consultation	ultérieure.
       12007/12/19   18:05:54 
    						
    							1
    English
    
    English
    	IMPORTANT	SAFETY	INSTRUCTIONS
    Basic	precautions	should	always	be	followed	when	using	an	electrical	unit,	including	the	following.
    Please	ensure	that	you	read	all	instructions	before	using	the	Household	Foot	Massager.
    DANGER	–	To	reduce	the	risk	of	electric	shock:
    	 1.	 Always	unplug	the	unit	immediately	after	use.
    	 .	 Always	unplug	the	unit	before	cleaning.
    WARNING	–	 To	reduce	the	risk	of	burns,	fire,	electric	shock,	or	injury	to	persons:
    	 1.	 Always	insert	the	power	plug	all	the	way	into	the	outlet	to	reduce	the	risk	of	short-circuit	and	fire.
    	 . 		The	unit	should	never	be	left	unattended	when	plugged	in. 	Always	unplug	the	unit	when	not	in	
    use.
    	 3. 		Close	and	continuous	supervision	is	necessary	when	the	unit	is	used	by	people	who	are	limited	in	their	ability	to	
    move	or	communicate.
    	 4.	 Only	use	the	unit	for	the	purpose	described	in	these	instructions. 	
    	 5.	 Do	not	stand	on	the	unit.
    	 6.	 Do	not	use	any	accessories	other	than	those	recommended	by	the	manufacturer.
    	 7.	 This	unit	should	not	be	used	by	children. 	Keep	children	away	from	the	unit.
    	 8.	 Do	not	use	the	unit	if	the	power	cord	or	power	plug	is	damaged. 	If	the	cord	or	plug	is	damaged,	it	must	be	
    replaced	by	an	authorized	service	center	or	qualified
    	repair	technician.	
    If
    
    	the	unit	is	not	working	properly,	if	it	has	been	dropped	or	damaged,	or	if	it	has	been	immersed	in	water,	return	
    it	to	the	nearest	authorized	service	center.
    	 9.	 Keep	power	cords	away	from	heated	surfaces. 	Do	not	carry	the	unit	by	the	power	cord.	Do	not	allow	pins,	
    rubbish	or	moisture	to	come	into	contact	with	the	plug.
    10.	 Do	not	use	the	unit	on	top	of	heating	appliances,	such	as	electric	carpets,	etc. 	Do	not	operate	the	unit	under	
    blanket	or	pillow. 	Excessive	heating	can	occur	and	cause	fire,	electric	shock,	or	injury	to	persons.
    11.	 Do	not	use	the
    	unit	in	bathrooms	or	other	damp	or	humid	places	as	this	may	cause	electric	shock	or	cause	the	
    unit	to	malfunction. 	Do	not	spill	water,	etc. 	onto	the	controller.
    1.	 Do	not	use	the	unit	outdoors.
    13.	 Do	not	use	the	unit	in	places	where	aerosol	spray	products	are	in	use	or	where	oxygen	is	being	used.
    14.	 When	unplugging	the	unit,	turn	off	all	controls	before	removing	the	plug	from	power	outlet. 	Do	not	use	the	unit	
    with	a	transformer	as	this	may	lead	to	malfunction	or	electric	shock.
    15.	 To	avoid	electric	shock	or	injury,	do	not	attempt	to	open	or	disassemble	any	part	of
    	the	unit	as	it	contains	no	
    user-serviceable	parts.
    16.	 Do	not	pull	the	angle	lock	lever	either	when	seated	on	the	unit	or	when	legs	are	placed	in	the	leg	wells.
    17.	 Ensure	the	massage	section	is	securely	locked	into	position	after	adjusting	the	angle	and	before	sitting	or	 placing	legs	in	the	leg	wells.
    18.	 Do	not	allow	metal	pins,	dust,	or	water	to	come	into	contact	with	the	power	plug.
    19.	 Never	operate	the	appliance	with	the	air	openings	blocked. 	Keep	the	air	openings	free	of	lint,	hair,	and	the	like.
    0.	 Never	drop	or	insert	any	object	into	any	openings.
    1.	 Do	not	use	the	unit	if
    	the	cloth	cover	is	torn	or	if	the	internal	mechanism	is	exposed.
    SAVE	 THESE	INSTRUCTIONS
    	SAFETY	PRECAUTIONS
    WARNING: 	To	avoid	the	risk	of	injury:
    	 1.	 The	following	persons	should	consult	with	a	physician	before	using	this	product	if	undergoing	treatment	from	
    the	physician:
    	(1)	 Those	using	an	implanted	electronic	device,	such	as	a	pacemaker,	which	is	susceptible	to	electromagnetic	
    interference
    	 (
    
    )	 Those	with	malignant	tumors
    	 (3)	 Those	with	heart	problems
    	 (4)	 Those	who	are	pregnant	or	who	have	recently	given	birth
    	 (5)	 Those	with	sensory	loss	caused	by	advanced	peripheral	circulatory	disorders,	such	as	due	to	diabetes
    	 (6)	 Those	with	osteoporosis,	sprains,	or	acute	pain	due	to	torn	muscles
    	 (7)	 Those	intending	to	use	the	massager	on	a	treated	or	ailing	part
    	 (8)	 Those	
    having	a	body	temperature	(fever)	of	100°F	(38°C)	or	higher	(Example: 	when	feeling	weak	or	having	
    severe	symptoms	of	acute	inflammation,	such	as	malaise,	chills,	or	fluctuating	blood	pressure)
    	 (9)	 Those	requiring	rest	or	in	physically	poor	shape
    (10)	 Those	with	serious	leg	circulatory	problems
    (11)	 Besides	the	above,	those	feeling	physical	discomfort
    	 .	 Use	is	contraindicated	in	the	following	persons.	 P
    
    ersons	whose	physician	has	forbidden	their	receiving	massage. 	(Example:	those	with	thrombosis	[clotting],	
    severe	aneurysm,	acute	varicosis,	dermatitis	or	skin	infection	[including	inflammation	of	subcutaneous	tissue],	
    etc.)
    	 3.
    
    	 Do	not	use	the	unit	against	bare	skin. 	While	thin	clothing	may	increase	effectiveness,	exposing	the	skin	directly	
    to	
    the	massager	may	irritate	the	skin. 		
    Do
    
    	not	use	the	unit	for	any	purpose	other	than	for	foot	and	calf	massages. 	Do	not	attach	hard	objects	such	as	
    jewelry	to	the	legs	during	use.
    	 4.	 While	using	the	massager,	if	you	start	feeling	sick	or	if	the	massage	seems	painful,	stop	using	it	immediately. 		
    	 While	using	the	massager,	if	the	pressure	seems	too	strong,	the	movement	of	the	massager	can	be	stopped	at	
    any	time	by	pressing	the	OFF/ON	button.
    	 5.	 Do	not	go	to	sleep	while	using	the	unit. 		Do	not	use	the	unit	after	drinking	alcohol.
    	 6.	 Do	not	allow	children
    	to	use	or	play	on	the	unit.
    	 7.	 Do	not	unplug	the	unit	or	turn	it	off	during	operation. 		Unplug	the	unit	immediately	if	there	is	a	power	outage.
    	 8.	 When	moving	the	unit,	lift	it	with	both	hands	using	the	hand	grips. 	Do	not	drag	it.
    	 9.	 Use	only	on	a	level	surface. 	Carefully	position	the	unit.
    10.	 Use	 the	unit	 only	 for	the	 intended	 purpose	as	a	footrest	 for	massage	 of	the	 legs	 and	feet,	 or	as	 a	stool	 for	sitting. 	
    (Do	not	stand	on	the	unit	or	use	it	as	a	stepstool.)
    11.	 Do	not	forcefully	remove	legs	from	the	wells	during	use.
    1.	 Do
    	not	use	with	the	unit	turned	on	its	side.
    13.	 Do	not	allow	use	by	two	or	more	people	at	the	same	time.
    14.	 Do	not	insert	hands	or	fingers	between	the	massage	section	and	the	frame.
    15.	 Do	not	use	the	unit	for	any	purpose	other	than	for	foot	and	calf	massages.
       1-22007/12/19   18:05:55 
    						
    							1
    English
    
    English
    	IMPORTANT	SAFETY	INSTRUCTIONS
    Basic	precautions	should	always	be	followed	when	using	an	electrical	unit,	including	the	following.
    Please	ensure	that	you	read	all	instructions	before	using	the	Household	Foot	Massager.
    DANGER	–	To	reduce	the	risk	of	electric	shock:
    	 1.	 Always	unplug	the	unit	immediately	after	use.
    	 .	 Always	unplug	the	unit	before	cleaning.
    WARNING	–	 To	reduce	the	risk	of	burns,	fire,	electric	shock,	or	injury	to	persons:
    	 1.	 Always	insert	the	power	plug	all	the	way	into	the	outlet	to	reduce	the	risk	of	short-circuit	and	fire.
    	 . 		The	unit	should	never	be	left	unattended	when	plugged	in. 	Always	unplug	the	unit	when	not	in	
    use.
    	 3. 		Close	and	continuous	supervision	is	necessary	when	the	unit	is	used	by	people	who	are	limited	in	their	ability	to	
    move	or	communicate.
    	 4.	 Only	use	the	unit	for	the	purpose	described	in	these	instructions. 	
    	 5.	 Do	not	stand	on	the	unit.
    	 6.	 Do	not	use	any	accessories	other	than	those	recommended	by	the	manufacturer.
    	 7.	 This	unit	should	not	be	used	by	children. 	Keep	children	away	from	the	unit.
    	 8.	 Do	not	use	the	unit	if	the	power	cord	or	power	plug	is	damaged. 	If	the	cord	or	plug	is	damaged,	it	must	be	
    replaced	by	an	authorized	service	center	or	qualified
    	repair	technician.	
    If
    
    	the	unit	is	not	working	properly,	if	it	has	been	dropped	or	damaged,	or	if	it	has	been	immersed	in	water,	return	
    it	to	the	nearest	authorized	service	center.
    	 9.	 Keep	power	cords	away	from	heated	surfaces. 	Do	not	carry	the	unit	by	the	power	cord.	Do	not	allow	pins,	
    rubbish	or	moisture	to	come	into	contact	with	the	plug.
    10.	 Do	not	use	the	unit	on	top	of	heating	appliances,	such	as	electric	carpets,	etc. 	Do	not	operate	the	unit	under	
    blanket	or	pillow. 	Excessive	heating	can	occur	and	cause	fire,	electric	shock,	or	injury	to	persons.
    11.	 Do	not	use	the
    	unit	in	bathrooms	or	other	damp	or	humid	places	as	this	may	cause	electric	shock	or	cause	the	
    unit	to	malfunction. 	Do	not	spill	water,	etc. 	onto	the	controller.
    1.	 Do	not	use	the	unit	outdoors.
    13.	 Do	not	use	the	unit	in	places	where	aerosol	spray	products	are	in	use	or	where	oxygen	is	being	used.
    14.	 When	unplugging	the	unit,	turn	off	all	controls	before	removing	the	plug	from	power	outlet. 	Do	not	use	the	unit	
    with	a	transformer	as	this	may	lead	to	malfunction	or	electric	shock.
    15.	 To	avoid	electric	shock	or	injury,	do	not	attempt	to	open	or	disassemble	any	part	of
    	the	unit	as	it	contains	no	
    user-serviceable	parts.
    16.	 Do	not	pull	the	angle	lock	lever	either	when	seated	on	the	unit	or	when	legs	are	placed	in	the	leg	wells.
    17.	 Ensure	the	massage	section	is	securely	locked	into	position	after	adjusting	the	angle	and	before	sitting	or	 placing	legs	in	the	leg	wells.
    18.	 Do	not	allow	metal	pins,	dust,	or	water	to	come	into	contact	with	the	power	plug.
    19.	 Never	operate	the	appliance	with	the	air	openings	blocked. 	Keep	the	air	openings	free	of	lint,	hair,	and	the	like.
    0.	 Never	drop	or	insert	any	object	into	any	openings.
    1.	 Do	not	use	the	unit	if
    	the	cloth	cover	is	torn	or	if	the	internal	mechanism	is	exposed.
    SAVE	 THESE	INSTRUCTIONS
    	SAFETY	PRECAUTIONS
    WARNING: 	To	avoid	the	risk	of	injury:
    	 1.	 The	following	persons	should	consult	with	a	physician	before	using	this	product	if	undergoing	treatment	from	
    the	physician:
    	(1)	 Those	using	an	implanted	electronic	device,	such	as	a	pacemaker,	which	is	susceptible	to	electromagnetic	
    interference
    	 (
    
    )	 Those	with	malignant	tumors
    	 (3)	 Those	with	heart	problems
    	 (4)	 Those	who	are	pregnant	or	who	have	recently	given	birth
    	 (5)	 Those	with	sensory	loss	caused	by	advanced	peripheral	circulatory	disorders,	such	as	due	to	diabetes
    	 (6)	 Those	with	osteoporosis,	sprains,	or	acute	pain	due	to	torn	muscles
    	 (7)	 Those	intending	to	use	the	massager	on	a	treated	or	ailing	part
    	 (8)	 Those	
    having	a	body	temperature	(fever)	of	100°F	(38°C)	or	higher	(Example: 	when	feeling	weak	or	having	
    severe	symptoms	of	acute	inflammation,	such	as	malaise,	chills,	or	fluctuating	blood	pressure)
    	 (9)	 Those	requiring	rest	or	in	physically	poor	shape
    (10)	 Those	with	serious	leg	circulatory	problems
    (11)	 Besides	the	above,	those	feeling	physical	discomfort
    	 .	 Use	is	contraindicated	in	the	following	persons.	 P
    
    ersons	whose	physician	has	forbidden	their	receiving	massage. 	(Example:	those	with	thrombosis	[clotting],	
    severe	aneurysm,	acute	varicosis,	dermatitis	or	skin	infection	[including	inflammation	of	subcutaneous	tissue],	
    etc.)
    	 3.
    
    	 Do	not	use	the	unit	against	bare	skin. 	While	thin	clothing	may	increase	effectiveness,	exposing	the	skin	directly	
    to	
    the	massager	may	irritate	the	skin. 		
    Do
    
    	not	use	the	unit	for	any	purpose	other	than	for	foot	and	calf	massages. 	Do	not	attach	hard	objects	such	as	
    jewelry	to	the	legs	during	use.
    	 4.	 While	using	the	massager,	if	you	start	feeling	sick	or	if	the	massage	seems	painful,	stop	using	it	immediately. 		
    	 While	using	the	massager,	if	the	pressure	seems	too	strong,	the	movement	of	the	massager	can	be	stopped	at	
    any	time	by	pressing	the	OFF/ON	button.
    	 5.	 Do	not	go	to	sleep	while	using	the	unit. 		Do	not	use	the	unit	after	drinking	alcohol.
    	 6.	 Do	not	allow	children
    	to	use	or	play	on	the	unit.
    	 7.	 Do	not	unplug	the	unit	or	turn	it	off	during	operation. 		Unplug	the	unit	immediately	if	there	is	a	power	outage.
    	 8.	 When	moving	the	unit,	lift	it	with	both	hands	using	the	hand	grips. 	Do	not	drag	it.
    	 9.	 Use	only	on	a	level	surface. 	Carefully	position	the	unit.
    10.	 Use	 the	unit	 only	 for	the	 intended	 purpose	as	a	footrest	 for	massage	 of	the	 legs	 and	feet,	 or	as	 a	stool	 for	sitting. 	
    (Do	not	stand	on	the	unit	or	use	it	as	a	stepstool.)
    11.	 Do	not	forcefully	remove	legs	from	the	wells	during	use.
    1.	 Do
    	not	use	with	the	unit	turned	on	its	side.
    13.	 Do	not	allow	use	by	two	or	more	people	at	the	same	time.
    14.	 Do	not	insert	hands	or	fingers	between	the	massage	section	and	the	frame.
    15.	 Do	not	use	the	unit	for	any	purpose	other	than	for	foot	and	calf	massages.
       1-22007/12/19   18:05:55 
    						
    							3
    English
    4
    English
    	OPERATING	PRECAUTIONS
    WARNING:	To	avoid	damaging	the	foot	massager, 	follow	these	precautions:
    1.	 Do	not	sit	on	or	drop	the	controller.		Do	not	pull	the	controller	cord	or	the	power	cord.
    .	 Do	not	treat	the	foot	massager	roughly,	turn	the	foot	massager	on	its	side,	turn	the	foot	massager	over	or	stand	 on	it.
    3.	 If	the	foot	massager	functions	abnormally,	immediately	turn	off	the	power	and	have	the	massager	checked	by	 an	authorized	service	center.
    4.	 Never	modify	the	unit. 	Also	do	not	attempt	to	dismantle	or	repair	the	unit.
    5.	 Do	not	repeatedly	operate	any	switch	at	short	intervals. 		Such	action	may	cause	the	switch	to	malfunction.
    6.	 Some	
    noise	may	be	heard	coming	from	the	foot	massager	while	in	use. 		This	is	due	to	the	structure	of	the	foot	
    massager	and	is	normal.
    7.	 Do	not	use	when	body	or	clothing	are	wet.
    8.	 The	unit	must	not	be	used	in	 “wet	rooms”	(sauna,	swimming	pool)	or	outdoors.
    	PART	NAMES	AND	FUNCTIONS
    FOOT	MASSAGER	UNITCONTROLLER
    • Flashes to indicate areas 
    currently being massaged.
    Massage Area Display
    • Located on right-hand  side.
    • Fine adjustment of position possible.
    • Selection can be made from two programs. 
    Program Selection buttons
    OFF/ON button
    Angle Lock Lever
    Hand Grip
    Frame Section Cloth Cover
    Power CordController
    Massage Section
    (Integrated Airbags)
    Integrated Shiatsu Sheets
    Intensity indicator
    • Allows switching between  different massage modes. 
    Mode switch button
    • Allows the intensity of the massage to be adjusted in 
    three steps. 
    Intensity Control button
    Controller Holder
    Mode indicator
       3-42007/12/19   18:05:55 
    						
    							3
    English
    4
    English
    	OPERATING	PRECAUTIONS
    WARNING:	To	avoid	damaging	the	foot	massager, 	follow	these	precautions:
    1.	 Do	not	sit	on	or	drop	the	controller.		Do	not	pull	the	controller	cord	or	the	power	cord.
    .	 Do	not	treat	the	foot	massager	roughly,	turn	the	foot	massager	on	its	side,	turn	the	foot	massager	over	or	stand	 on	it.
    3.	 If	the	foot	massager	functions	abnormally,	immediately	turn	off	the	power	and	have	the	massager	checked	by	 an	authorized	service	center.
    4.	 Never	modify	the	unit. 	Also	do	not	attempt	to	dismantle	or	repair	the	unit.
    5.	 Do	not	repeatedly	operate	any	switch	at	short	intervals. 		Such	action	may	cause	the	switch	to	malfunction.
    6.	 Some	
    noise	may	be	heard	coming	from	the	foot	massager	while	in	use. 		This	is	due	to	the	structure	of	the	foot	
    massager	and	is	normal.
    7.	 Do	not	use	when	body	or	clothing	are	wet.
    8.	 The	unit	must	not	be	used	in	 “wet	rooms”	(sauna,	swimming	pool)	or	outdoors.
    	PART	NAMES	AND	FUNCTIONS
    FOOT	MASSAGER	UNITCONTROLLER
    • Flashes to indicate areas 
    currently being massaged.
    Massage Area Display
    • Located on right-hand  side.
    • Fine adjustment of position possible.
    • Selection can be made from two programs. 
    Program Selection buttons
    OFF/ON button
    Angle Lock Lever
    Hand Grip
    Frame Section Cloth Cover
    Power CordController
    Massage Section
    (Integrated Airbags)
    Integrated Shiatsu Sheets
    Intensity indicator
    • Allows switching between  different massage modes. 
    Mode switch button
    • Allows the intensity of the massage to be adjusted in 
    three steps. 
    Intensity Control button
    Controller Holder
    Mode indicator
       3-42007/12/19   18:05:55 
    						
    							5
    English
    6
    English
    	BEFORE	USING	THE	UNIT
    SETTING	UP	THE	UNIT
    Position	the	Unit.
    Placed	with	angle	lock	lever	
    on	right-hand	side.
    Position	the	unit	so	that	the	angle	lock	lever	is	on	the	right-hand	
    side	of	the	user.
    The	massage	section	is	contoured	to	
    fit	the	shape	of	the	calves	and	feet.
    Use	on	a	level	surface. 	
    Place	a	mat	under	the	unit	to	avoid	marking	of	floor	surfaces. 	
    Please	use	a	mat	large	enough	to	accommodate	the	unit	
    [minimum	size: 	6	in.	×	13	in. 	(66	cm	×	33	cm)]. 	
    •
    •
    •
    Connect	the	Power	Plug	to	an	Outlet.
    Use	in	a	safe	and	stable	environment.
    	
    •
    Adjust	to	an	Appropriate	Angle	for	Use.
    How	to	Adjust	the	Angle
    Pull	the	angle	lock	lever	outward, 	and	adjust	to	an	angle	suited	to	use. 	
    The	angle	is	adjustable	in	eight	steps. 	
    When	one	of	these	steps	is	reached,	you	will	hear	a	 “click”	indicating	that	it	
    is	locked	into	position. 	
    *		 After	making	adjustments,	check	to	make	sure	that	the	massage	section	
    is	firmly	locked	into	place. 	
    *		 Take	care	not	to	pinch	hands	or	fingers,	etc. 	when	making	adjustments.	
    *		 Check	to	make	sure	the	power	cord	and	controller	cord	have	not	become	
    caught	in	or	wrapped	around	the	
    unit.	
    Angle	lock	lever
    To	use	as	a	massagerTo	use	as	a	footrest
    To	massage	the	soles	of	the	feet To	massage	the	calves
    Usage	ExamplesUsage	Examples
    	USING	THE	UNIT
    MASSAGING	LEGS	AND	FEET
    1	Place	legs	or	feet	in	the	wells	of	the	footrest.
    The	footrest	is	positioned	so	that	the	angle	lock	lever	is	on	the	user’s	right-hand	side. 	
    Gently	place	legs	or	feet	into	the	wells	so	as	not	to	tip	the	unit	over. 	
    •
    •
    When	massaging	the	calves	
    When	massaging	the	feet	
    •		Feet	are	placed	in	the	center	of	
    the	massage	section. 	
    2	Press		to	turn	on	the	power. 	
    The	massage	will	not	start	until	a	program	has	been	selected. 	
    •
    Buttons	 	
    star
    t	flashing.
    3	Select		or		according	to	the	part	you	want	
    to	massage. 		
    An	automatic	program	will	start. 	
    See	Page	7	for	a	description	of	the	programs. 	
    The	massage	will	start	in	Combined	mode. 	Both	massage	
    indicator	lamps	will	light	up. 	
    It	is	also	possible	to	change	the	massage	mode. 	(See	Page	7)
    •
    •
    •
    •
    4	The	unit	will	automatically	stop	when	the	massage	has	finished.
    	
    Operation	will	stop	when	the	set	program	has	finished.	(Approx.	15	minutes)	
    	To	stop	operation	during	a	massage, 	press	.	
    All	operation	of	the	unit	will	stop. 	
    •
    •
       5-62007/12/19   18:05:56 
    						
    							5
    English
    6
    English
    	BEFORE	USING	THE	UNIT
    SETTING	UP	THE	UNIT
    Position	the	Unit.
    Placed	with	angle	lock	lever	
    on	right-hand	side.
    Position	the	unit	so	that	the	angle	lock	lever	is	on	the	right-hand	
    side	of	the	user.
    The	massage	section	is	contoured	to	
    fit	the	shape	of	the	calves	and	feet.
    Use	on	a	level	surface. 	
    Place	a	mat	under	the	unit	to	avoid	marking	of	floor	surfaces. 	
    Please	use	a	mat	large	enough	to	accommodate	the	unit	
    [minimum	size: 	6	in.	×	13	in. 	(66	cm	×	33	cm)]. 	
    •
    •
    •
    Connect	the	Power	Plug	to	an	Outlet.
    Use	in	a	safe	and	stable	environment.
    	
    •
    Adjust	to	an	Appropriate	Angle	for	Use.
    How	to	Adjust	the	Angle
    Pull	the	angle	lock	lever	outward, 	and	adjust	to	an	angle	suited	to	use. 	
    The	angle	is	adjustable	in	eight	steps. 	
    When	one	of	these	steps	is	reached,	you	will	hear	a	 “click”	indicating	that	it	
    is	locked	into	position. 	
    *		 After	making	adjustments,	check	to	make	sure	that	the	massage	section	
    is	firmly	locked	into	place. 	
    *		 Take	care	not	to	pinch	hands	or	fingers,	etc. 	when	making	adjustments.	
    *		 Check	to	make	sure	the	power	cord	and	controller	cord	have	not	become	
    caught	in	or	wrapped	around	the	
    unit.	
    Angle	lock	lever
    To	use	as	a	massagerTo	use	as	a	footrest
    To	massage	the	soles	of	the	feet To	massage	the	calves
    Usage	ExamplesUsage	Examples
    	USING	THE	UNIT
    MASSAGING	LEGS	AND	FEET
    1	Place	legs	or	feet	in	the	wells	of	the	footrest.
    The	footrest	is	positioned	so	that	the	angle	lock	lever	is	on	the	user’s	right-hand	side. 	
    Gently	place	legs	or	feet	into	the	wells	so	as	not	to	tip	the	unit	over. 	
    •
    •
    When	massaging	the	calves	
    When	massaging	the	feet	
    •		Feet	are	placed	in	the	center	of	
    the	massage	section. 	
    2	Press		to	turn	on	the	power. 	
    The	massage	will	not	start	until	a	program	has	been	selected. 	
    •
    Buttons	 	
    star
    t	flashing.
    3	Select		or		according	to	the	part	you	want	
    to	massage. 		
    An	automatic	program	will	start. 	
    See	Page	7	for	a	description	of	the	programs. 	
    The	massage	will	start	in	Combined	mode. 	Both	massage	
    indicator	lamps	will	light	up. 	
    It	is	also	possible	to	change	the	massage	mode. 	(See	Page	7)
    •
    •
    •
    •
    4	The	unit	will	automatically	stop	when	the	massage	has	finished.
    	
    Operation	will	stop	when	the	set	program	has	finished.	(Approx.	15	minutes)	
    	To	stop	operation	during	a	massage, 	press	.	
    All	operation	of	the	unit	will	stop. 	
    •
    •
       5-62007/12/19   18:05:56 
    						
    							7
    English
    8
    English
    Changing	the	Massage	Mode
    Press	.
    The	massage	mode	used	can	be	switched	via	the	controller.	
    •		Press	once	to	
    switch	to	
    Knead	A. •		
    Press	a	second	
    time	to	switch	
    to	Knead	B. •		
    Press	a	third	
    time	to	switch	
    to	Combined. •		
    Press	a	fourth	
    time	to	switch	
    back	to	Knead	A.
    The	mode	can	also	be	changed	midway	through	a	massage. 		
    When
    	the	mode	is	changed,	the	new	selected	massage	will	start	after	all	
    the	air	has	been	released. 	
    •
    •
    Knead	A	A	slow	and	thorough	massage	is	given	using	an	upward	squeezing	action	on	the	selected	part	
    of	the	body.
    	
    Recommended	for	people	who	are	prone	to	swelling. 	
    •
    •
    Knead	B	Muscles	are	pleasantly	loosened	with	rhythmical	pressure.	
    Recommend	for	tired	leg	muscles	from	exercising,	etc. 	
    •
    •
    CombinedFatigue	is	pleasantly	relieved	and	blood	circulation	in	the	legs	is	promoted	by	a	variety	of	
    massage	actions	of	varying	rhythms,	in	addition	to	that	of	
    modes	Knead	A	and	B	above.	
    •
    Massage	Mode	DescriptionsMassage	Mode	Descriptions
    Adjusting	the	Intensity	
    Press	.
    The	intensity	of	the	massage	can	be	adjusted	in	three	steps.
    	
    One	lamp	lights	up	with	each	step	adjusted. 	
    Intensity	3
    Intensity	
    Intensity	1Stronger
    Weaker
    •
    •
    AFTER	COMPLETING	
    THE	MASSAGE
    Disconnect	the	Power	Plug.
    When	not	in	use	for	extended	periods	of	time, 	please	disconnect	the	power	plug	from	the	outlet	as	a	
    measure	to	save	energy.	
    (Noise
    
    	may	be	heard	when	operationally	idle,	as	approx. 	5	W	of	electricity	are	used	even	when	not	in	operation.)
    CAUTION
    Unplug	the	power	plug	from	the	outlet	when	the	unit	is	not	in	use.	
    F
    ailure	to	observe	this	precaution	may	result	in	electrical	fire	due	to	deterioration	of	insulation	caused	by	dust	
    and	moisture.
    Always	hold	the	power	plug, 	not	the	power	cord,	when	unplugging	from	an	outlet.	
    F
    
    ailure	to	observe	this	precaution	may	result	in	electric	shock	or	short-circuit.
    •
    •
    Return	the	Massage	Section	to	Its	Original	Position.
    Pull	the	angle	lock	lever	outward	and	return	the	massage	section.
    	
    (See	Page	5)	
    •
    Return	the	Controller	to	the	Holder.
    Both	the	controller	and	the	controller	cord	can	be	stored	
    in	the	holder	on	the	underside	of	the	unit.
    	
    •
    Retur n	the	controller	to	the	controller	holder.	
    •
    •
       7-82007/12/19   18:05:57 
    						
    							7
    English
    8
    English
    Changing	the	Massage	Mode
    Press	.
    The	massage	mode	used	can	be	switched	via	the	controller.	
    •		Press	once	to	
    switch	to	
    Knead	A. •		
    Press	a	second	
    time	to	switch	
    to	Knead	B. •		
    Press	a	third	
    time	to	switch	
    to	Combined. •		
    Press	a	fourth	
    time	to	switch	
    back	to	Knead	A.
    The	mode	can	also	be	changed	midway	through	a	massage. 		
    When
    	the	mode	is	changed,	the	new	selected	massage	will	start	after	all	
    the	air	has	been	released. 	
    •
    •
    Knead	A	A	slow	and	thorough	massage	is	given	using	an	upward	squeezing	action	on	the	selected	part	
    of	the	body.
    	
    Recommended	for	people	who	are	prone	to	swelling. 	
    •
    •
    Knead	B	Muscles	are	pleasantly	loosened	with	rhythmical	pressure.	
    Recommend	for	tired	leg	muscles	from	exercising,	etc. 	
    •
    •
    CombinedFatigue	is	pleasantly	relieved	and	blood	circulation	in	the	legs	is	promoted	by	a	variety	of	
    massage	actions	of	varying	rhythms,	in	addition	to	that	of	
    modes	Knead	A	and	B	above.	
    •
    Massage	Mode	DescriptionsMassage	Mode	Descriptions
    Adjusting	the	Intensity	
    Press	.
    The	intensity	of	the	massage	can	be	adjusted	in	three	steps.
    	
    One	lamp	lights	up	with	each	step	adjusted. 	
    Intensity	3
    Intensity	
    Intensity	1Stronger
    Weaker
    •
    •
    AFTER	COMPLETING	
    THE	MASSAGE
    Disconnect	the	Power	Plug.
    When	not	in	use	for	extended	periods	of	time, 	please	disconnect	the	power	plug	from	the	outlet	as	a	
    measure	to	save	energy.	
    (Noise
    
    	may	be	heard	when	operationally	idle,	as	approx. 	5	W	of	electricity	are	used	even	when	not	in	operation.)
    CAUTION
    Unplug	the	power	plug	from	the	outlet	when	the	unit	is	not	in	use.	
    F
    ailure	to	observe	this	precaution	may	result	in	electrical	fire	due	to	deterioration	of	insulation	caused	by	dust	
    and	moisture.
    Always	hold	the	power	plug, 	not	the	power	cord,	when	unplugging	from	an	outlet.	
    F
    
    ailure	to	observe	this	precaution	may	result	in	electric	shock	or	short-circuit.
    •
    •
    Return	the	Massage	Section	to	Its	Original	Position.
    Pull	the	angle	lock	lever	outward	and	return	the	massage	section.
    	
    (See	Page	5)	
    •
    Return	the	Controller	to	the	Holder.
    Both	the	controller	and	the	controller	cord	can	be	stored	
    in	the	holder	on	the	underside	of	the	unit.
    	
    •
    Retur n	the	controller	to	the	controller	holder.	
    •
    •
       7-82007/12/19   18:05:57 
    						
    							9
    English
    10
    English
    CLEANING	AND	MAINTENANCE
    CAUTION
    When	performing	cleaning	and	maintenance, 	always	disconnect	the	power	cord	from	the	outlet. 	Never	
    touch	the	power	plug	with	wet	hands. 		
    -
    
    	Failure	to	observe	these	precautions	may	result	in	electric	shock	or	burns.
    •
    Frame	Section	and	Plastic	Parts
    (1)		
    Wipe	these	areas	with	a	cloth	that	has	been	soaked	in	a	mild	detergent	and	then	
    thoroughly	wrung	out.
    ()		 Next	wipe	with	a	cloth	that	has	been	moistened	with	just	water	and	thoroughly	
    wrung	out.	
    *
    
    	Make	sure	you	thoroughly	wring	out	the	cloth	first	when	cleaning	the	controller.
    (3)		 Allow	the	unit	to	dry	naturally.
    Please	do	NOT	use	thinners, 	benzine	or	alcohol.
    •
    Areas	Covered	with	Fabric
    (1)		 Wipe	these	areas	with	a	cloth	that	has	been	soaked	in	a	mild	detergent	and	then	
    thoroughly	wrung	out.
    ()		 Use	a	mild	detergent	and	brush	on	areas	where	the	fabric	has	become	particularly	
    soiled. 	Be	careful	not	to	brush	the	fabric	too	much	as	you	may	damage	it.
    (3)		 Next	wipe	the	fabric	with	a	cloth	that	has	been	moistened	with	just	water	and	
    thoroughly	wrung	out.
    (4)		 Allow	the	fabric	to	dry	naturally.
    Please	do	NOT	use	thinners, 	benzine	or	alcohol.
    •
    Areas	Covered	with	Synthetic	Leather
    Wipe	these	areas	with	a	soft, 	dry	cloth.	(Do	NOT	use	cloths	containing	any	kind	
    of	chemical, 	etc.)
    If	the	synthetic	leather	becomes	particularly	dirty, 	promptly	
    soak	a	soft	cloth	in	
    water	or	a	3-5%	solution	of	mild	detergent, 	wring	it	out	thoroughly	and	tap	the	
    surface	with	it. 	Next,	rinse	the	cloth	in	water, 	wring	it	out	thoroughly	and	then	
    wipe	any	remaining	detergent	from	the	surface, 	wipe	the	surfaces	with	a	soft	
    dry	cloth	and	allow	them	to	dry	naturally. 		
    (Do
    
    	NOT	use	a	hair	dryer	to	try	to	dry	the	surfaces	more	quickly.)
    Wipe	off	stubborn	stains	with	a	
    commercially	available	melamine	foam	sponge	
    soaked	in	a	neutral	detergent.
    Wearing	of	denim, 	colored,	patterned	or	other	clothing	with	a	tendency	to	fade	should	
    be	avoided	during	use, 	as	it	could	lead	to	discoloration	of	the	synthetic	leather.
    Do	not	allow	these	areas	to	come	in	contact	with	plastic	for	extended	periods	
    of	time	as	this	may	lead	to	discoloration.
    Please	do	NOT	use	thinners, 	benzine	or	alcohol.
    •
    •
    •
    •
    •
    •
    STORING	
    THE	UNIT
    When	moving	the	unit,	carry	it	using	both	hands. 		
    Hand
    	grips	are	provided	on	the	upper	part	of	the	unit. 	
    Do	NOT	store	in	the	following	places.
    -	Places	accessible	to	children	
    -
    
    	Places	with	exposure	to	water
    -		 Places	with	exposure	to	high	heat,	humidity,	direct	sunlight,	or	air	containing	
    dust	and	salt,	etc.
    -	Places	with	exposure	to	vibration,	shock	or	tilting
    -	Places	where	chemicals	are	stored	or	corrosive	gases	are	produced	
    •
    •
    Hand	Grip
    	TROUBLESHOOTING
    Noises	during	operation
    The	following	sounds	during	operation	are	caused	by	the	construction	of	the	unit	and	are	normal.
    Sound	of	inflating	air
    Sound	of	deflating	air
    Sound	of	a	pump	working	
    Clattering	sound	from	massage	section	
    Clacking	sound	from	the	massage	section	when	adjusting	the	angle	
    Symptom Cause	and	Remedy
    Emits	 “beep” 	sound	and	then	
    stops. The
     	unit	has	automatically	stopped	because	15	minutes	have	passed	since	the	
    massage	started. 	Please	take	a	10-minute	break	after	completing	a	15-minute	
    massage. 	
    Does	not	operate. Is	the	power	plug	connected?
    Firmly	insert	the	power	plug.	(See	page	5)
    Is	there	a	break	in	the	power	cord?
    Foot	Massager	is	damaged. Immediately	stop	use.
    If	there	is	still	a	problem	after	checking	the	Foot	Massager,	immediately	stop	use. 	To	prevent	accidents	in	this	case,	
    be	sure	to	ask	your	dealer	to	inspect/repair	the	unit.
    	SPECIFICATIONS
    Product	Name: 		Foot	Massager
    Power	Supply: 		AC	10	V	60	Hz
    Power	Consumption: 		5	W
    Automatic	Shut-Off: 		Approx. 	15	min.
    Dimensions	(H	×	 W	×	D):		Approx. 	17
    3⁄8	in.	×	51⁄4	in.	×	11⁄4	in.	(440	mm	×	640	mm	×	310	mm)
    Weight	of	Unit: 		Approx.	331⁄8	lb	(15	kg)
    •
    •
    •
    •
    •
       9-102007/12/19   18:05:58 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Household Foot Massager Ep30102 Operating Instructions