SERIAL 6789 1345 2 11 Connections SERIAL Terminals connection Notes: • Use the RS-232C straight cable to connect the computer to the Plasma Display. • The computer shown is for example purposes only. • Additional equipment and cables shown are not supplied with this set. The SERIAL terminal conforms to the RS-232C interface specifi cation, so that the Plasma Display can be controlled by a computer which is connected to this terminal. The computer will require software which allows the sending and receiving of control data which satis fi es the conditions given below. Use a computer application such as programming language software. Refer to the documentation for the computer application for details. The SERIAL terminal is used when the Plasma Display is controlled by a computer. Basic format for control data The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent. Start (02h) 3-character command (3 bytes)Colon Parameter(s) (1 - 5 bytes) End (03h) STX C1 C2 C3 P1 P2 P3 P4 :P5 ETX Notes: • If multiple commands are transmitted, be sure to wait for the response for the fi rst command to come from this unit before sending the next command. • If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer. • SL1A, SL1B, SL2A and SL2B of Command IMS are available only when a dual input terminal board is attached. Pin layout for SERIAL Terminal COMPUTER RS-232C Straight cable D-sub 9p Command Parameter Control details PON None Power ON POF None Power OFF AVL ** Volume 00 - 63 AMT 0 Audio MUTE OFF 1 Audio MUTE ON IMS None SL1 SL2 SL3 PC1 SL1A SL1B SL2A SL2BInput select (toggle) Slot1 input Slot2 input Slot3 input PC input Slot1 input (INPUT1A) Slot1 input (INPUT1B) Slot2 input (INPUT2A) Slot2 input (INPUT2B) DAM None ZOOM FULL JUST NORM SELF SJST SNOM SFUL ZOM2Screen mode select (toggle) ZOOM (For Video/SD/PC signal)FULL JUST (For Video/SD signal) 4:3 (For Video/SD/PC signal) Panasonic Auto (For Video signal)JUST (For HD signal) 4:3 (For HD signal) H-FILL (For HD signal) ZOOM (For HD signal) With the power off, this display responds to PON command only. CommandSignal level RS-232C compliant Synchronization method Asynchronous Baud rate 9600 bps Parity None Character length 8 bits Stop bit 1 bit Flow control - Signal names for D-sub 9P connector Pin No. Details2R X D3T X D5GND4 • 6Non use78(Shorted in this set) 1 • 9NC These signal names are those of computer speci fi cations. Communication parameters (Male) (Female)
PC SLOT1SLOT2SLOT3 PR/CR/R PB/CB/BY/GAUDIORLCOMPONENT/RGB IN HDMI AV OUTHDMI AV OUT PC IN AUDI SLOT1SLOT3 PR/CR/R PB/CB/BY/GAUDIORLCOMPONENT/RGB INSLOT2 VIDEOAUDIORLAUDIORLAV INS VIDEO VIDEO OUTS VIDEO OUTAUDIOOUT RLAUDIO OUT RL BA 12 Connections HDMI connection (for TH-42PH12U, TH-50PH12U) This unit has terminal boards equivalent to Dual HDMI Terminal Board (TY-FB10HMD) and BNC Component Video Terminal Board (TY-42TM6A) as standard equipment. HDMI cables DVD player DVD player [Pin assignments and signal names] 1931 4218 Note: Additional equipment and HDMI cables shown are not supplied with this set. Pin No.SignalPin No.Signal 1T.M.D.S Data2+11T.M.D.S Clock Shield 2T.M.D.S Data2 Shield12T.M.D.S Clock- 3T.M.D.S Data2-13CEC4T.M.D.S Data1+14Reserved (N.C. on device)5T.M.D.S Data1 Shield 6T.M.D.S Data1-15SCL7T.M.D.S Data0+16SDA 8T.M.D.S Data0 Shield17DDC/CEC Ground 9T.M.D.S Data0-18+5V Power10T.M.D.S Clock+19Hot Plug Detect AV connection (for TH-42PH12L, TH-50PH12L) This unit has a terminal board equivalent to BNC Dual Video Terminal Board (TY-FB9BD) and BNC Component Video Terminal Board (TY-42TM6A) as standard equipment. CAMCORDERVCR Note: Additional equipment, cables and adapter plugs shown are not supplied with this set. S VIDEO VCR Example of input signal source
SLOT3 PR/CR/R PB/CB/BY/GAUDIORLCOMPONENT/RGB IN AUDIO OUT Y , P B , P R , OUT P R P B Y L R COMPONEN T VIDEO OUT 13 Connections COMPONENT / RGB connection Notes: • Change the “COMPONENT/RGB-IN SELECT” setting in the “SET UP” menu to “COMPONENT” (when COMPONENT signal connection) or “RGB” (when RGB signal connection). • Additional equipment, cables and adapter plugs shown are not supplied wi\ th this set. • SYNC ON G signal is needed. RCA-BNC adapter plug Computer RGB Camcorder or DVD Example of input signal source Digital TV-SET-TOP-BOX (DTV-STB)
INPUT MENUENTER/+/ VOL-/ 14 Power Indicator Remote Control Sensor Power ON / OFF Connecting the AC cord plug to the Plasma Display. Fix the AC cord plug securely to the Plasma Display with the clamper. (see page 8, 9) Connecting the plug to the Wall Outlet. Note: When disconnecting the AC cord, be absolutely sure to disconnect the AC cord plug at the socket outlet fi rst. Press the Power switch on the Plasma Display to turn the set on: Power-On. Power Indicator: Green Press the button on the remote control to turn the Plasma Display off. Power Indicator: Red (standby) Press the button on the remote control to turn the Plasma Display on. Power Indicator: Green Turn the power to the Plasma Display off by pressing the switch on the unit, when the Plasma Display is on or in standby mode. Note: During operation of the power management function, the power indicator t\ urns orange in the power off state.
PCFULL English (UK)Deutsch Français Italiano Español ENGLISH (US) Русский OSD LANGUAGE SET SELECT PRESENT TIME SETUPPRESENT TIME OF DAY MON 99:99 SET PRESENT TIME OF DAY99:99DAY MON PRESENT TIME SETUPPRESENT TIME OF DAY MON 99:99 SET PRESENT TIME OF DAY10:00DAY TUE LANDSCAPE PORTRAIT DISPLAY ORIENTATION 15 From the second time on, the below screen is displayed for a while (set\ ting condition is an example). When fi rst switching on the unit Following screen will be displayed when the unit is turned on for the fi rst time. Select the items with the remote control. Unit buttons are invalid. OSD LANGUAGE PRESENT TIME SETUP DISPLAY ORIENTATION 1 Select the language. 2 Set. 1 Select “DAY” or “PRESENT TIME OF DAY”. 2 Setup “DAY” or “PRESENT TIME OF DAY”. 1 For vertical installation, select “PORTRAIT”. 2 Set. Notes: • Once the items are set, the screens wont be displayed when switching on\ the unit next time. • After the setting, the items can be changed in the following menus. OSD LANGUAGE PRESENT TIME SETUP DISPLAY ORIENTATION 1 Select “SET”. 2 Set. Power ON / OFF
INPUT MENU ENTER/ + / VOL - / INPUT MENU ENTER/+/VOL-/ 16 Selecting the input signal Select the input signals to be connected by installing the optional Terminal Boards. Press to select the input signal to be played back from the equipment which has been connected to the Plasma Display. Input signals will change as follows: Notes: • Selecting is also possible by pressing the INPUT button on the unit. • Input terminal will not be selected if the terminal board is not install\ ed into the SLOT. • Select to match the signals from the source connected to the component/R\ GB input terminals. • In 2 screen display, the same input mode cannot be selected for the main picture and sub picture. • Image retention (image lag) may occur on the plasma display panel when\ a still picture is kept on the panel for an extended period. The function that darkens the screen slightly is activated to prevent image retention, but this function is not the pe\ rfect solution to image retention. INPUT1INPUT2APC INPUT3INPUT2B SLOT2 is for dual input so that you can select INPUT2A or INPUT2B for INPUT2. For TH-42PH12U, TH-50PH12U INPUT2A : HDMI signal terminal in SLOT2 INPUT2B : HDMI signal terminal in SLOT2 For TH-42PH12L, TH-50PH12L INPUT2A : VIDEO signal terminal in SLOT2 INPUT2B : S VIDEO signal terminal in SLOT2
INPUT MENUENTER/+/VOL-/ 17 Basic Controls MENU Screen ON / OFF Each time the MENU button is pressed, the menu screen will switch. INPUT button (Input signal selection) (see page 16) Main Power On / Off Switch Power Indicator The Power Indicator will light. • Power-OFF .... Indicator not illu minated (The unit will still consume some power as long as the power cord is still inserted into the wall outlet.) • Standby ........ Red • Power-ON ...... Green • DPMS (POWER MANAGEMENT) ....................... Orange (With PC input signal.) Volume Adjustment Volume Up “+” Down “–” When the menu screen is displayed: “+” : press to move the cursor up “–” : press to move the cursor down(see page 19) Enter / Aspect button (see page 19) Normal Viewing PICTURE SET UP SOUND POS. /SIZE Remote control sensor Main Unit
18 Basic Controls Standby (ON / OFF) button The Plasma Display must fi rst be plugged into the wall outlet and turned on at the power switch (see page 14). Press this button to turn the Plasma Display On, from Standby mode. Press it again to turn the Plasma Display Off to Standby mode. ACTION button Press to make selections. ASPECT button Press to adjust the aspect. POS. /SIZE button PICTURE button Sound mute On / Off Press this button to mute the sound. Press again to reactivate sound. Sound is also reactivated when power is turned off or volume level is changed. N button POSITION buttons INPUT button Press to select INPUT1, INPUT2, INPUT3 and PC input SLOTS sequentially. (see page 16) When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B) MULTI Window buttons Digital Zoom Remote Control Transmitter AUTO SETUP button Automatically adjusts the position/ size of the screen. SET UP button SOUND button Volume Adjustment Press the Volume Up “+” or Down “–” button to increase or decrease the sound volume level. R button (see page 19) Press the R button to return to previous menu screen. OFF TIMER button The Plasma Display can be preset to switch to stand- by after a fi xed period. The setting changes to 30 minutes, 60 minutes, 90 minutes and 0 minutes (off timer cancelled) each time the button is pressed. 30 60 090 When three minutes remain, “OFF TIMER 3” will fl ash. The off timer is cancelled if a power interruption occurs. OFF TIMER 90 1 2 3 4 PC 4:3 10:00 RECALL buttonPress the “RECALL” button to display the current system status. 1 Input label2 Aspect mode 3 Off timer The off timer indicator is displayed only when the off timer has been set. 4 Clock display
2/2 ADVANCED SETTINGS COLOR TEMP COLOR MANAGEMENT NORMAL OFF ON PICTURE 0 NORMAL NORMALIZE AUTO SETUP POS. /SIZE V-POS 0 H-POS V-SIZEDOT CLOCK H-SIZE CLOCK PHASE OVER SCAN 000 0 1/2 SIGNAL EXTENDED LIFE SETTINGS SET UP PC OFF STANDBY SAVE OFF POWER MANAGEMENTOFF AUTO POWER OFF OFF OSD LANGUAGE ENGLISH ( US ) COMPONENT/RGB-IN SELECT RGB INPUT LABEL SCREENSAVER POWER SAVE 2/2 SET UP MULTI DISPLAY SETUP SET UP TIMER PRESENT TIME SETUP DISPLAY ORIENTATIONLANDSCAPE 3D Y/C FILTER (NTSC) COLOR SYSTEM SIGNAL ON 3 : 2 PULLDOWN Panasonic AUTO (4 : 3) [ VIDEO ] NOISE REDUCTIONREFRESH RATE AUTO OFF 4:3 OFF 100 Hz SCREENSAVER START FUNCTION MODE SCROLLING BAR ONLYOFF PRESENT TIME OF DAY 99:99 99:99MON PRESENT TIME SETUP PRESENT TIME OF DAY MON 99:99 SET PRESENT TIME OF DAY DAY 0:00 0:00 SET UP TIMER POWER OFF FUNCTION POWER OFF TIME POWER ON TIME POWER ON FUNCTION OFF OFF PRESENT TIME OF DAY 99:99 1/2 PICTURE NORMAL NORMALIZE STANDARD 25 0 0 0 5 BRIGHTNESS SHARPNESS PICTURE MENU COLOR PICTURE TINT 0 0 0 0 0 0 2/2 W/B LOW B W/B HIGH R W/B LOW R W/B LOW G W/B HIGH G W/B HIGH B ADVANCED SETTINGS 0 0 2.2 1/2 BLACK EXTENSION AGC GAMMA INPUT LEVEL ADVANCED SETTINGS NORMAL NORMALIZE OFF 2/2 SOUND OUT LEFT CHANNEL RIGHT CHANNEL CHANNEL 1 CHANNEL 1 OFF LEVEL METER OFF SDI SOUND OUTPUT EXPRESS SETTINGS CUSTOM SETTINGS RESET EXTENDED LIFE SETTINGS 19 On-Screen Menu Displays Remote Control Unit 1Display the menu screen. Press to select. (Example: PICTURE menu)MENU Press several times. Each time the MENU button is pressed, the menu screen will switch. Normal Viewing PICTURE SOUND POS. /SIZE SET UP 2Select the item. 1/2 25 0 0 0 5 PICTURE NORMAL NORMALIZE STANDARD BRIGHTNESS SHARPNESS PICTURE MENU COLOR PICTURE TINT ( Example: PICTURE menu) Select. Select. Press. 3Set.Set. Set. Press. 4Exit the menu. Press. Press to return to the previous menu. MENU Press several times. Overview Note: Menu that cannot be adjusted is grayout. Adjustable menu changes depending on signal, input and menu setting. 0 0 0 1/2 SOUND NORMAL NORMALIZE STANDARD TREBLE AUDIO MENU BALANCE BASS MAIN AUDIO OUT (PIP) × 2 MULTI DISPLAY SETUP HORIZONTAL SCALE OFF A1 OFF AI-SYNCHRONIZATION VERTICAL SCALE LOCATION OFF SEAM HIDES VIDEO × 2 MULTI DISPLAY SETUP
20 TH-42PH12UTH-50PH12U Power Source 110 - 127 V AC, 50/60 Hz Power Consumption Power on 380 W 465 W Stand-by condition Save OFF 1.2 W, Save ON 0.4 W Save OFF 1.2 W, Save ON 0.5 W Power off condition 0.2 W 0.2 W Plasma Display panel Drive method : AC type 42-inch, 16:9 aspect ratio Drive method : AC type 50-inch, 16:9 aspect ratio Screen size 36.2” (921 mm) (W) × 20.4” (518 mm) (H) × 41.6” (1,057 mm) (diagonal) 43.5” (1,106 mm) (W) × 24.4” (622 mm) (H) × 49.9” (1,269 mm) (diagonal) (No.of pixels) 786,432 (1,024 (W) × 768 (H)) [3,072 × 768 dots] 1,049,088 (1,366 (W) × 768 (H)) [4,098 × 768 dots] Operating condition Temperature 32 °F - 104 °F (0 °C - 40 °C) 32 °F - 104 °F (0 °C - 40 °C) Humidity 20 % - 80 % 20 % - 80 % Applicable signals Scanning format 525 (480) / 60i · 60p, 625 (575) / 50i · 50p, 750 (720) / 60\ p · 50p, 1125 (1080) / 60i · 60p · 50i · 50p · 24p · 25p · 30p · 24sF, 1250 (1080) / 50i PC signals VGA, SVGA, XGA SXGA, UXGA ···· (compressed) Horizontal scanning frequency 15 - 110 kHz Vertical scanning frequency 48 - 120 Hz Connection terminals HDMI A-B TYPE A Connector × 2 COMPONENT/RGB IN Y/G (BNC) P B/B (BNC), PR/R (BNC) AUDIO IN (RCA PIN JACK × 2) with sync 1.0 Vp-p (75 Ω) 0.7 Vp-p (75 Ω) 0.5 Vrms PC IN (HIGH-DENSITY MINI D-SUB 15PIN) B/P B/CB : R/PR/CR : HD/VD: AUDIO IN (M3 JACK) Y or G with sync 1.0 Vp-p (75 Ω) Y or G without sync 0.7 Vp-p (75 Ω) 0.7 Vp-p (75 Ω) 0.7 Vp-p (75 Ω) 1.0 - 5.0 Vp-p (high impedance) 0.5 Vrms SERIAL EXTERNAL CONTROL TERMINAL (D-SUB 9PIN) RS-232C COMPATIBLE SPEAKERS 6 Ω, 16 W [8 W + 8 W] (10 % THD) Accessories Supplied Remote Control TransmitterN2QAYB000432 Batteries AA Size × 2 Fixing band TMME203 × 1 Dimensions (W × H × D) 40.2” (1,020 mm) × 24.1” (610 mm) × 3.5” (89 mm) 47.7” (1,210 mm) × 28.5” (724 mm) × 3.8” (95 mm) Mass (weight) main unit only approx. 55.2 lbs approx. 75.0 lbs with speakers approx. 64.0 lbs approx. 86.0 lbs Note: Design and speci fi cations are subject to change without notice. Mass and dimensions shown \ are approximate. Specifi cations