20 Setting (checking) the measurement notification time 19 M/R Calling up readings from memory Readings can be recalled after being saved without having to switch the unit on. 1. Press the Memory/Recall button. •The average readings of all recorded measurements are displayed. •The mark will be displayed (Fig. 11-a). •When, for example, readings from 90 measurements have been saved the average of the readings from 90 measurements will be displayed. 2. Press the Memory/Recall button to display readings starting with from the most recent measurement. •Each time the Memory/Recall button is pressed readings are displayed in order of the most recent measurement (Fig. 11-c, 11-d). •No readings will be displayed when there are none in the memory. 3.Press the On/Off and Start button to switch off the unit. If you forget to switch off the unit it will do so automatically after approx. 30 seconds. Deleting all data stored in memory (1) Recall stored data using the Memory/Recall button. (2)Press the Memory/Recall button again and hold it (for approx. 3 seconds) until all readings are deleted. NOTE: Readings from individual measurements cannot be deleted. (3)When data has been deleted the mark and will be displayed on the screen. Fig. 11-a Fig. 11-c Fig. 11-b Fig. 11-dTo let you take measurements at the same time every day, 3 times per day can be set as notification times. 1. Press the Set button on the top surface of the blood pressure monitor (Fig. 12-a). •Notification Time 1 will blink (Fig. 12-b). *If date and time have not been set, the display will change to the date/time setting display. 2. Press the Set button again. •The and will blink (Fig. 12-c). 3. Press the Adjust button to display . •The and will blink (Fig. 12-d). •Notification sound will sound. •Notification sound will not sound. •When is displayed and the Set button is pressed, the time becomes and the and will light. 4.(1)Press the Set button. The hour value will blink (Fig. 12-e). (2)Press the Adjust button repeatedly to set the desired hour.Fig. 12-a Fig. 12-c Fig. 12-b Fig. 12-d Fig. 12-e (After approx. one second.) &864@&OH Ö”´

22 21 5. (1) Oprima el botón Puesta. El valor de los minutos destellará (Fig. 12-f). (2)Oprima el botón Ajustar repetidamente para establecer los minutos deseados. •Para ajustar sólo la Hora de Notificación 1, oprima el botón Arrancar/Parar para comletar el ajuste. •Para ajustar las Horas de Notificación 2 y 3, siga los pasos 6 y 7 de más abajo. 6Oprima el botón Puesta. La Hora de Notificación 2 destellará (Fig. 12-g). Repita los pasos 2 a 5 para establecer la hora de notificación deseada. 7Cuando se ha completado el ajuste de la Hora de Notificación 2, oprima el botón Puesta. La Hora de Notificación 3 destellará. Repita los pasos 2 a 5 para establecer la hora de notificación deseada. 8Cuando el ajuste de la Hora de Notificación 3 ha sido completado, oprima el botón Puesta. Las horas ajustadas para las Horas de Notificación 1 a 3 serán mostradas automáticamente a intervalos de 2 segundos (Fig. 12-h). 9Para completar el ajuste, oprima el botón Arrancar/Parar.To change the notification time setting: 1. Press the Set button on the top surface of the blood pressure monitor. (Notification Time 1 will blink.) •To change the setting for Notification Time 2 or 3, press the Change button to display Notification Time 2 or 3. 2. Press the Set button twice. The hour value will blink. 3. Press the Adjust button repeatedly to set the desired hour. 4. (1) Press the Set button. The minute value will blink (2) Press the Adjust button repeatedly to set the desired minute. 5. Press the Start/Stop button to complete the setting. To cancel the measurement notification sound: 1. Press the Set button on the top surface of the blood pressure monitor. (Notification Time 1 will blink.) •To change the setting for Notification Time 2 or 3, press the Adjust button to display Notification Time 2 or 3. 2. Press the Set button once. The and will blink. 3. Press the Adjust button. will be displayed. 4. Press the Start/Stop button to complete the setting. •When the set time is reached, the measurement notification sound will sound to notify you that its time to take a measurement. •If the set time is reached in the middle of taking a measurement, the measurement notification sound will not sound. •When the measurement notification sound sounds, it can be stopped by pressing the Start/Stop button. If the button is not pressed, the sound stops after 1 minute. •If the blood pressure monitor is put into a bag, desk, etc., it may not be possible to hear the measurement notification sound. Advice: If a record table is made of the measurement values taken around the same time, you can easily see your own daily blood pressure changes. Fig. 12-f Fig. 12-g Fig. 12-h Fig. 12-i &864@&OH Ö”´

24 23 Troubleshooting Display The “E” blinks on the display Status before error Pressurization to above 280 mmHgwas performed. (Re-pressurization was performed several times.) Pressure decreased suddenly and appeared in the display. mark only blinks a few times, or not at all. Cuff does not inflate. Check points Check whether measurements are being taken correctly and whether you are assuming the correct posture. Make sure the unit is on the palm side of the wrist. (See pages 12-13.) Check whether the pressure cuff is attached to your wrist correctly. Make sure the unit is on the palm side of the wrist. (See page 12.) Care and Maintenance 1. Use a dry, soft cloth to clean the device. If desired, use a cloth lightly dampened with tap water and a mild detergent to clean the device. DO NOT use alcohol, benzine, thinner or other harsh chemicals to clean the device or cuff. 2. When the unit will not be used for a long time (30 days or more), be sure to remove the batteries. Otherwise, the batteries may leak and damage the unit. Storing the Monitor 1. Fold the pressure cuff as indicated. (Fig. 13-a) 2.Put the blood pressure monitor in the storage case. (Fig. 13-b) •Be sure not to pinch the pressure cuff or 2cm gauge when closing the case. 1 2 0 8 0 If the 2cm gauge is attached, straighten it out. Fig. 13-a Fig. 13-b NOTE:When the batteries are removed, the date, time, and measurement record are erased. Set the date and time again the next time you use the unit. &864@&OH Ö”´

26 25 Specifications Method of measurement: Display: Measuring range: Measurement accuracy: Power source: Operating environment: Storage environment: Wrist circumference measurement range: Dimensions (H#W#D): Weight: Oscillometric System Digital LCD Blood pressure: 0 - 280 mmHg Pulse rate: 30 - 160 pulse/min. Pressure: ±3 mmHg Pulse rate: ±5% Two 1.5-volt alkaline (AAA/LR03) batteries 10°C to 40°C (50°F to 104°F) 30% to 85% RH -20°C to 60°C (-4°F to 140°F) 10% to 95% RH 12.5 to 22.0 cm (5 to 8-3/4) 54.0#83. 0#26.0 mm (2-1/8#2-1/4#1-1/32) 90 g(3.2 oz.) not including batteries If the unit still appears to provide unusual or erroneous readings, consult your physician. If the unit does not appear to be functioning properly, contact Panasonic at 1-800-338-0552 . Specifications are subject to change without notice. Symptom The systolic pressure value or diastolic pressure value is high. The systolic pressure value or diastolic pressure value is low. The measured values differ significantly. The measured value differs from that measured by the doctor. The measured value is different for each measurement. Varying sounds and pressurization speeds occur during inflation of the cuff. The measured value obtained is different from that measured at the upper arm. Possible cause •The hand with the cuff was held too low and not at heart level. (See page 12) •The cuff was not attached properly. (See page 12.) •You moved your hand or body or you spoke during measurement. (See page 12.) •The hand with the cuff was held too high and not at heart level. (See page 12.) •You moved your hand or body or you spoke during measurement. (See page 12.) •Your posture was not the same for all measurements, or measurements were taken without sufficient time in between. Always wait approximately 5 minutes before taking another reading, and above all, relax. •Blood pressure varies in response to minute changes in your mental state, such as your reaction to your doctor taking the measurement. One way to check this is to bring the unit to your doctor’s office and directly compare the readings taken by your physician. •Relax for at least 5 minutes and then take another measurement. •Changes in operating sounds and pressurization speeds are normal and occur due to the fact that measurements are being made as the cuff is being inflated. •For persons with certain circulation problems, there may be substantial differences in blood pressure values measured at the upper arm versus at the wrist. &864@&OH Ö”´