Home > Panasonic > Air Conditioner > Panasonic E9_12nkua Operating Instructions Manual

Panasonic E9_12nkua Operating Instructions Manual

Here you can view all the pages of manual Panasonic E9_12nkua Operating Instructions Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

QUICK GUIDEQUICK GUIDEGUIDE SOMMAIREGUIDE SOMMAIRE
Operating Instructions
Air Conditioner
F569580
ENGLISH 2-10
Operating Instructions
Air Conditioner
Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, read these operating 
instructions thoroughly and keep them for future 
reference. 
FRANÇAIS 11-20
Instructions d’utilisation
Climatiseur
Merci d’avoir acheté un climatiseur Panasonic.
Instructions d’installation en annexe.
Avant d’utiliser le...

Page 2

2
TABLE OF CONTENTSTABLE OF CONTENTS
SAFETY PRECAUTIONS
2~3
MULTI AIR CONDITIONER 
SYSTEM
4
INDOOR UNIT
5
REMOTE CONTROL
6~7
TROUBLESHOOTING
8~9
INFORMATION
10
QUICK GUIDE
BACK COVER
NOTENOTE
The illustrations in this manual are for 
explanation purposes only and may 
differ from the actual unit. They are 
subjected to change without notice for 
future improvement.
SAFETY PRECAUTIONS
To prevent personal injury, injury to others, or property damage, please 
comply with the following.
Incorrect operation...

Page 3

3
ENGLISH
 CAUTIONCAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water, benzene, 
thinner or scouring powder to avoid damage or 
corrosion at the unit.
Do not use for preservation of precise equipment, 
food, animals, plants, artwork or other objects. This 
may cause quality deterioration, etc.
Do not use any combustible equipment in front of 
the airfl ow outlet to avoid fi re propagation.
Do not expose plants or pet directly to airfl ow to 
avoid injury, etc.
Do not touch the sharp...

Page 4

4
MULTI AIR CONDITIONER SYSTEM
Multi Split Outdoor Unit
(CU-2E18NBU, CU-5E36QBU)
DEFINITION
Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.
Living roomLiving room
Multi Split Outdoor UnitMulti Split Outdoor Unit
INDOOR UNITINDOOR UNIT
• It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the fi rst unit 
that turned on.
• During operation, heating and cooling mode can not be...

Page 5

5
ENGLISH
• Switch off  the power at the circuit breaker before cleaning.
• Do not touch the aluminium fi n, sharp parts may cause injur y.
CLEANING  INSTRUCTIONSCLEANING  INSTRUCTIONSHINTHINT
•  Do not use benzene, thinner or scouring powder.
•  Use only soap ( pH7) or neutral household detergent.
•  Do not use water hotter than 104°F/40°C.•  To ensure optimal performance of the unit, cleaning 
maintenance has to be carried out at regular intervals. A 
dirty unit may cause malfunction and you may see...

Page 6

6
FAN SPEED
AIR SWING
MODE
QUIET
TEMP
OFF/ON
POWERFUL
TIMER
SET
CANCEL ON
OFF1
23
SETAC
RC
AUTO
HEAT
COOL
DRYFAN
SPEED
AIR
SWING
REMOTE CONTROL
Maximum distance: 26ft/8m
INDICATOR
 
POWER(Green)
 TIMER(Orange)
 QUIET(Orange)
 POWERFUL(Orange)
342 Remote 
Control display
65
7
1
Press the remote control’s button
1
TO TURN ON OR OFF THE UNIT
•  Please be aware of the OFF indication on the remote 
control display to prevent the unit from starting/stopping 
improperly.
2
 TO SET TEMPERATURE
•  Selection range...

Page 7

7
ENGLISH
TO SET THE TIMERTO SET THE TIMER
•  To turn ON or OFF the unit at a preset time.
ON
OFF1
2SET
Select ON or 
OFF timerSet the time Confi rm
•  To cancel ON or OFF timer, press 
ON or OFF then 
press 
CANCEL.
•  When ON Timer is set, the unit may start earlier (up 
to 35 minutes) before the actual set time in order to 
achieve the desired temperature on time.
•  Timer operation is based on the clock set in the 
remote control and repeats daily once set. For clock 
setting, please refer to Remote...

Page 8

8
TROUBLESHOOTING
The following symptoms do not indicate malfunction.The following symptoms do not indicate malfunction.
SYMPTOMSYMPTOMCAUSECAUSE
Mist emerges from indoor unit.►•  Condensation effect due to cooling process.
Water fl owing sound during operation.►• Refrigerant fl ow inside the unit.
The room has a peculiar odor.►•  This may be due to damp smell emitted by the wall, 
carpet, furniture or clothing.
Indoor fan stops occasionally during automatic fan speed 
setting.►•  This helps to remove the...

Page 9

9
ENGLISH
The unit stops and the TIMER indicator blinks.The unit stops and the TIMER indicator blinks.
Use remote control to retrieve error code.
TIMER
SET
CANCEL ON
OFF1
23
SETAC
RC
1Press for 5 seconds.
3Press for 5 seconds to 
quit checking.
2Press until you hear beep sound, then write 
down the error code.
4Turn the unit off and reveal the error code to 
authorised dealer
• For certain errors, you may restart the unit for limited operation with 4 beeps when operation starts.
Diagnostic...

Page 10

10
INFORMATION
FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE
•  Check remote control batteries.
•  No obstruction at air inlet and air outlet vents.
•  Use Auto OFF/ON button to select Cooling/Heating operation. 
After 15 minutes of operation, it is normal to have the following 
temperature difference between air inlet and air outlet vents: 
Cooling: ≥ 14.4°F/8°C  Heating: ≥ 25.2°F/14°C
FOR EXTENDED NON-USE
•  Activate Heat mode for 2~3 hours to remove moisture left in the 
internal parts thoroughly to...