    Have a look at the manual Panasonic DLP Based Projector PT-D5600U PT-D5600UL PT-DW5000U PT-DW5000UL Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							41
    Indication of lamp monitor
    This projector is equipped with 3 indicators to show when a lamp needs replacement or there is an abnormal
    internal temperature. These lamps flash or light up to indicate a problem.
    Turn the power off and follow the steps below.
    Temperature monitor 
    (TEMP) indicator Lamp 1 monitor (LAMP 1) Lamp 2 monitor (LAMP 2) Power indicator
    • To solve any problems that the TEMP and LAMP monitor show, first turn the power off by
    following the steps on pages 23, 24.
    • If the power indicator blinks in red (3 times), the projector has malfunctioned. Please consult your
    dealer.Attention
    Name of monitor
    lampLamp
    indicationInformation
    High temperature
    inside. (WARNING)
    • Check if the
    ventilation port is
    blocked.
    • Is the room air
    temperature too high?
    • Is the air filter clogged
    with dust?
    Warm-up status 
    • Did you turn on the
    power when the
    ambient temperature
    was low 
    (approx. 0 °C)? 
    Checkpoint
    • Wait about five minutes in the
    current status.
    • Install the unit in a location
    having an ambient
    temperature from 0 to 45 °C. 
    • Remove the object that is
    blocking the ventilation port.
    • Move the projector to a
    temperature of 0 to 45 ˚C and
    the humidity of 20 to 80 % (no
    condensation).
    • Turn off the MAIN POWER
    switch using the procedure on
    page 24 and clean the air filter
    (refer to page 42).
    Lighting in
    red
    (lamp unit
    ON)
    Remedial measure
    Blinking in
    red
    (1 time)
    Blinking in
    red
    (2 times)
    The filter is clogged.
    High temperature
    inside
    (Standby condition)
    Blinking in
    red
    (3 times)Cooling fan has
    been stopped.
    • Turn off the main power supply
    (MAIN POWER) switch in the
    procedure shown on page 24
    and consult the distributor.
    • This lamp monitor lights up
    when the lamp unit used hours
    have reached 1 300 hours 
    (3 800 hours when long life
    lamp units are used). Request
    the dealer to replace the lamp
    unit.
    • Wait until the lamp has cooled
    off, and then turn on the
    power.
    • Did you notice a
    “REPLACE LAMP”
    message on the
    screen when turning
    on the projector
    power supply?
    • Did you turn the power
    back on immediately
    after turning it off?
    • Turn off the MAIN POWER
    switch using the procedure on
    page 24 and consult the
    dealer.
    • Some error has
    arisen in the lamp
    circuit.
    • Check for fluctuation
    (or drop) in the source
    voltage.
    Indicates the time
    for replacing the
    lamp unit.
    Error is detected in
    the lamp or lamp
    power.
    Lighting in
    red
    Blinking in
    red
    (3 times)
    Temperature 
    monitor
    TEMP
    Lamp monitor
    LAMP1       LAMP2 
    						
    							42
    Cleaning and replacement of air filter
    If too much dust accumulates on the air filter, [AIR FILTER] appears at the lower left of the screen, and the
    temperature monitor (TEMP) will blink once. If even more dust is allowed to accumulate, the temperature inside the
    main unit will rise, the temperature monitor (TEMP) will blink twice, and the power is turned off.
    Clean the air filter section once every 100 hours or so as a guideline depending on the location of projector
    operation.
    It appears only for 30 seconds within 3 minutes after the power is turned on. It disappears if any of the buttons
    on the rear side of the main unit or on the remote control is pressed.
    Procedure of cleaning
    Turn off the main power and remove the power plug from the receptacle.
    Turn off the main power supply observing the procedure (Powering off the projector) on page 24 and then
    remove the power plug.
    Dismantle the air filter.
    There are two air filters, one at the left and one at the right.
    Use your finger to pull the air filter tab toward you, and remove it from the main unit.
    Set the air filter.
    Set the air filter in the reverse order to step  .
    Clean the air filter.
    Suck off deposited dust with a vacuum cleaner.
    • Do not to suck in the air filter itself.
    • Do not rinse off the air filter with water.  Doing so will impair the filter’s ability to provide
    protection from dust.Attention
    • Fit the air filters into place with the filter material facing the back.
    (The left and right filters have the same shape.)
    • The air filter must be fitted in place when using the projector.
    Using the projector without the air filter fitted inside, dirt and dust are sucked into the projector,
    causing failure.Attention
    • If cleaning cannot remove the dust completely, then it is a sign to replace the air filter. Consult the
    dealer. In addition, when the lamp unit is replaced, also replace the air filter.
    • Be absolutely sure to use the air filter specifically designed for use with the projector.
    Note
    Air filter 
    						
    							43
    Replacing the lamp unit
    Precautions on lamp unit replacement
    Remove the power plug and confirm that the surroundings of the lamp unit have cooled off.
    Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled,
    explosion might result.
    A used lamp unit may burst if it is handled violently.
    For disposition of used lamps, request an industrial waste disposal contractor.
    Do not reset the cumulative time, except when the lamp unit has been replaced with a new unit.
    If you continue to use a lamp after the replacement time, the lamp may break.
    Phillips screwdriver is necessary when replacing a lamp unit.
    Take care not to slip your hand when using a screwdriver.
    • A lamp unit is an optional part. Contact the dealer.
    Replacement lamp unit model No.: ET-LAD55 (single bulb), ET-LAD55W (double bulbs)
    Rating: 300W
    Long life lamp unit model No.: ET-LAD55L (single bulb), ET-LAD55LW (double bulbs)
    Rating: 160W
    • Other lamps than specified above cannot be used. Be sure to use the specified lamp.Attention
    Timing of lamp unit replacement
    The lamp used for the light source has its due life. The life of light source lamp used in the main unit is 1 500
    hours1(when “LAMP POWER” is “HIGH” and “LAMP SELECT” is “DUAL”). However, it may happen that the
    lamp becomes dead (will not light) by the time of 1 500 hours1depending on the characteristics of individual
    lamps and working conditions (lamps may reduce their life affected by the times of lighting and the intervals
    between previous lighting and next lighting). Therefore, it is strongly recommended for the user to keep a spare
    bulb.
    If your lamp unit is not replaced after 1 300 hours
    2(with “LAMP POWER” set at “HIGH”), power supply will be
    turned off automatically at the time of 1 500 hours1, entering a standby state. After 1 500 hours1of initial
    lighting, power supply is turned off automatically about 10 minutes later, entering a standby state even if it is
    turned on again.
    Indication after 1 300 hours2(with “LAMP POWER” set at “HIGH”)
    When lamp unit used hours have reached 1 300 hours2, lamp monitor
    (LAMP1 or LAMP2) light up including standby state.
    Further, an on-screen indication will appear for about 30 seconds as
    shown in the diagram on the left, recommending replacement of lamp unit.
    (The indication on the left diagram will disappear after about 30 seconds or
    when either control button on the rear of main unit or remote control button
    is operated.)
    After the time of 1 500 hours
    1, the on-screen indication will not disappear
    unless the menu (MENU) button is operated.
    REPLACE LAMP
    1 This time period is 4 000 hours when long life lamp units are used.
    2 This time period is 3 800 hours when long life lamp units are used.
    WARNING!
    When replacing the lamp, allow it to 
    cool for at least one hour before 
    handling it. 
    						
    							44
    Replacing the lamp unit
    Lamp unit replacement steps
    • After 1 500 hours (4 000 hours when long life lamp units are used) of operating the same lamp, it
    is only possible to operate the unit for approximately 10 minutes. Steps  to  must be
    completed within 10 minutes.Attention
    Turn the power off by following the steps on page 24, remove the power plug and
    confirm that the surroundings of the lamp unit have cooled off.
    Check that the fan has stopped running.
    Have a Phillips screwdriver ready ahead of time.
    Remove the screw securing the lamp unit
    cover, and then slide the lamp unit cover
    a little toward the left, and remove it.
    Remove the two screws securing the
    fan unit.
    Lamp unit cover
    Open the fan unit as shown in the
    figure.
    Remove the screws securing the lamp
    units (two for each unit), take hold of
    the handles, and remove the lamp units.
    Install the new lamp unit.
    Use a Phillips screwdriver to securely
    tighten the 2 lamp unit fixing screws
    (two for each unit).
    Lamp unit 2
    Handle
    Lamp unit 1 Lamp unit
    Fixing screws
    Secure the two screws for securing the
    fan unit tightly.
    Slide the cover a little toward the right,
    and secure it using the screw for
    securing the lamp unit cover tightly.
    • Firmly install the lamp unit and lamp
    unit cover. If not installed firmly, a
    protection circuit will function and the
    power will not be turned on.Attention
    • The lamp units are constructed in such
    a way that the screws in steps  and
    will not fall through completely.Note
    Caution
    The lamp unit will be hot after it has
    been used.
    You might get burned if you touch it while it is
    still hot. 
    						
    							45
    Insert the power cord plug into the wall outlet and then
    press the MAIN POWER switch.
    Press the “ I ” button so that a picture is projected onto
    the screen.
    Press the “MENU” button to display the MAIN MENU
    screen, and then press the  and  buttons to move
    the cursor to select “OPTION2”.
    Press the “ENTER” button to display the “OPTION2”
    screen, and select “SYSTEM INFORMATION” with the 
    and buttons.
    Press the “ENTER” button.
    The SYSTEM INFORMATION screen will be displayed.
    Press and hold the “ENTER” button on the projector or
    the remote control for approximately 3 seconds.
    An item “LAMP TIME RESET” will be added.
    Select the lamp which has been replaced with the  and
    buttons. 
    LAMP1: Replace the LAMP UNIT 1
    LAMP2: Replace the LAMP UNIT 2
    Press the ENTER button, and when the “LAMP TIME
    RESET” display flashes, press the ENTER button again.
    The used hours of the specified lamp unit will be reset to zero.
    When more than one lamp has been replaced, repeat the procedure from
    step .
    • If the power does not turn on even after turning the MAIN
    POWER switch “I”, turn the MAIN POWER “O”, confirm that
    the lamp unit and door are installed correctly, and turn on
    again.Attention
    MENU
    PICTURE
    ADVANCED MENU
    OPTI0N2
    TEST PATTERN OPTION1 POSITION
    LANGUAGE
    LAMP TIME RESET
    LAMP1
    LAMP2
      LAD55
      LAD55L   LAD55
    1433h
    0h
    1100h
    0h   LAD55L
    SYSTEM INFORMATION
    ROM VERSION
              HIGH
    200h
            TOTAL
    300h
    LAMP2 LOW SET RUNTIME
    300h
    LAMP1 LOW
    100h
    100h 1. 00. 00
    • When the “LAMP TIME RESET” display flashes, the lamp
    time reset can be canceled by pressing the MENU button.
    • The used hours of the lamp units can also be reset to zero
    by taking the following action instead of steps  to  .
    When lamp unit 1 has been replaced:
    In the standby mode, press the number buttons in the
    sequence of 737381, and then press the ENTER button.
    When lamp unit 2 has been replaced:
    In the standby mode, press the number buttons in the
    sequence of 737382, and then press the ENTER button.
    When the used hours have been reset, the lamp monitor
    (LAMP1/LAMP2) will flash for 3 seconds.Note 
    						
    							46
    Using Web Browser Control 
    Accessing from the Web browser
    Start the web browser on your PC, then
    enter the IP address which was set in
    the projector.
    Enter “user1” in the user name field,
    then enter the password in the
    password field.
    The default setting is “panasonic” (all lower case). If
    you have changed the password, enter the new
    password here. 
    The host name set in the projector is displayed in
    the “Realm” field.
    Click [OK]. 
    The Basic Control page is displayed.
    Password change page
    Click [Change password].
    • Avoid activating two or more Web browser
    simultaneously to work out setting or
    control actions.
    • Change the password first of all.Note This projector has networking functions which allow it to be controlled through a web browser on a PC. 
    The controlled items are:
    • Projector’s settings and adjustment
    • Projector’s status display
    • Transmission of a E-mail message when the projector has a problem
    Old password input field
    New password input field
    New password input field
    (re-enter for confirmation)
    Button for executing password change
    Button for erasing all entered characters 
    						
    							47
    Basic control page
    This page is the first page displayed when the projector is accessed through a web browser.
    To move from another page, click [Projector control], then [Basic control]. 
    E-mail set up button
    Click this item, and an E-mail setting page appears.
    Monitor information button
    Click this item, and the status of the projector is displayed.
    Detail control page
    Click [Projector control], then [Detail control] to display the Detail control page.
    Pressing these buttons controls the projector and updates the on-screen
    description on the right of the control page when control is finished.
    On-screen status is displayed, even if
    the on-screen of projector is set to off.
    Temporary stop of video
    Lens adjustment
    Test pattern display
    This button updates the on-screen
    description on the right of the control
    page with the latest information.
    Control button
    Click this item, and a
    projector control page
    appears.
    OSD
    (On-screen Display) display/non-
    display
    Power On/Off control 
    Shutter control
    Use these to select the input signals.
    Signal System Switching
    Network set up button
    Click this item, and a network set up page for IP address and
    other items appear.
    Change password button 
    						
    							48
    Using Web Browser Control 
    Error information page
    When  is displayed on the status information screen, click it to display the error details.
    • Depending on the nature of the error, the projector may be placed in the standby mode for its own
    protection.Note
    OK: Normal operation
    FAILED: Occurrence of trouble
    Monitor information page
    Click [Projector control], then [Status information] to display the Status information page.
    This page displays the projector statuses established for the items shown below.
    Displays the input switching status.
    Displays temperature of projector’s
    intake air.
    Displays temperature inside the
    projector.
    Displays the lamp1 lit hours.
    Displays the lamp2 lit hours.
    Displays used hours of the projector.
    Displays self-diagnosis information.
    Displays the type of projector.
    Displays the firmware version of the
    projector main unit.
    Displays temperature around the lamp.  
    						
    							49
    When [FAILED] has appeared for an item
    Parameter
    MAIN CPU BUS
    FAN
    OPTICS MODULE
    TEMPERATURE
    INPUT AIR TEMPERATURE
    AROUND LAMP
    TEMPERATURE
    LAMP REMAIN TIME
    LAMP STATUS
    SHUTTER
    AIR FILTER
    OPTICS MODULE TEMP.SENSOR
    INPUT AIR TEMP.SENSOR
    AROUND LAMP 
    TEMP. SENSOR
    BATTERY
    AIRFLOW SENSOR
    COLOR WHEEL
    Description
    Trouble has occurred in the microcomputer circuitry. Consult your dealer.
    Trouble has occurred in the fan or its drive circuit. Consult your dealer.
    The temperature inside the projector is high. It may be that the projector is
    being used where the ambient temperature is high such as near a heating
    appliance.
    The input air temperature is too high. It may be that the projector is being
    used where the ambient temperature is high such as near a heating
    appliance.
    The temperature near the lamp has risen very high.
    Something may be blocking the exhaust vent.
    The lamp runtime has exceeded the prescribed cumulative time, and it is
    now time to replace the lamp.
    The lamp has failed to light.
    Wait a short while for the lamp to cool off, and then turn on the power.
    Trouble has occurred in the shutter circuitry. Consult your dealer.
    Too much dust accumulates on the air filter.  
    Turn off the MAIN POWER switch using the procedure on page 24 and
    clean the air filter (refer to page 42).
    Trouble has occurred in the temperature detection sensor inside the
    projector. Consult your dealer.
    Trouble has occurred in the sensor used to detect the input air temperature.
    Consult your dealer.
    Trouble has occurred in the temperature detection sensor around lamps.
    Consult your dealer.
    The backup battery has been run out. Consult your dealer.
    Trouble has occurred in the air volume sensor. Consult your dealer.
    Trouble has occurred in the color wheel or the color wheel drive circuit.
    Consult your dealer.
    The user can modify the threshold temperature for sending
    temperature warning mail. If the temperature rises above the set
    value, control sends temperature warning mail.
    E-mail setup page
    With this projector, if a problem occurs or if the lamp usage time reaches a set value, an e-mail message can be
    sent to one or more preset e-mail addresses (maximum two addresses). Click [Projector Control], then [E-mail
    set up] to display the E-mail setup page.
    Select “Enable” to use the E-mail
    function.
    Enter the IP address or server name of
    the E-mail server (SMTP). The DNS
    server must be set if the server name is
    entered.
    Enter the E-mail address of the projector.
    (maximum 63 characters)
    The user can enter the location of, for
    example, the installed projector so that
    the recipient may easily identify the
    originator of the E-mail.
    (maximum 63 characters)
    The user can modify the minimum time
    interval of temperature warning mail.
    The default value is 60 minutes.  In this
    case, the user cannot send another mail
    for 60 minutes after sending previous
    temperature warning mail even the set
    warning temperature is reached again.
    (Continued on next page) 
    						
    							50
    Using Web Browser Control 
    Enter the E-mail address to which the E-
    mail is to be sent when two E-mail
    addresses are going to be used. Do not
    enter it when the second E-mail address
    is not going to be used.
    Check these boxes when E-mail is to be
    sent periodically to two E-mail
    addresses. E-mail will be sent at the
    times and on the days checked.
    E-mail setup page (Continuing)
    Select the conditions for sending E-mail.
    ERROR:
    an error is detected by self-diagnosis.
    LAMP RUNTIME:remaining lamp
    service time has reached the value set in
    the field.
    INPUT AIR TEMPERATURE:
    intake air temperature has reached the
    value set in the field.
    Periodic warning interval setting (e-mail
    is sent on the checked days of the
    week/times)
    Enter the E-mail address of your desired
    recipient.
    Select the conditions for sending the second E-mail.
    ERROR:an error is detected by self-diagnosis.
    LAMP RUNTIME:remaining lamp service time has reached the value set
    in the field.
    INPUT AIR TEMPERATURE: intake air temperature has reached the
    value set in the field.
    Button to update settings
    • Only alphanumeric characters, “.”, “_”, “-”, or “@” are available to set an e-mail address.
    Note 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic DLP Based Projector PT-D5600U PT-D5600UL PT-DW5000U PT-DW5000UL Operating Instructions