Have a look at the manual Panasonic DLP Based Projector PT-D5600U PT-D5600UL PT-DW5000U PT-DW5000UL Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
41 Indication of lamp monitor This projector is equipped with 3 indicators to show when a lamp needs replacement or there is an abnormal internal temperature. These lamps flash or light up to indicate a problem. Turn the power off and follow the steps below. Temperature monitor (TEMP) indicator Lamp 1 monitor (LAMP 1) Lamp 2 monitor (LAMP 2) Power indicator • To solve any problems that the TEMP and LAMP monitor show, first turn the power off by following the steps on pages 23, 24. • If the power indicator blinks in red (3 times), the projector has malfunctioned. Please consult your dealer.Attention Name of monitor lampLamp indicationInformation High temperature inside. (WARNING) • Check if the ventilation port is blocked. • Is the room air temperature too high? • Is the air filter clogged with dust? Warm-up status • Did you turn on the power when the ambient temperature was low (approx. 0 °C)? Checkpoint • Wait about five minutes in the current status. • Install the unit in a location having an ambient temperature from 0 to 45 °C. • Remove the object that is blocking the ventilation port. • Move the projector to a temperature of 0 to 45 ˚C and the humidity of 20 to 80 % (no condensation). • Turn off the MAIN POWER switch using the procedure on page 24 and clean the air filter (refer to page 42). Lighting in red (lamp unit ON) Remedial measure Blinking in red (1 time) Blinking in red (2 times) The filter is clogged. High temperature inside (Standby condition) Blinking in red (3 times)Cooling fan has been stopped. • Turn off the main power supply (MAIN POWER) switch in the procedure shown on page 24 and consult the distributor. • This lamp monitor lights up when the lamp unit used hours have reached 1 300 hours (3 800 hours when long life lamp units are used). Request the dealer to replace the lamp unit. • Wait until the lamp has cooled off, and then turn on the power. • Did you notice a “REPLACE LAMP” message on the screen when turning on the projector power supply? • Did you turn the power back on immediately after turning it off? • Turn off the MAIN POWER switch using the procedure on page 24 and consult the dealer. • Some error has arisen in the lamp circuit. • Check for fluctuation (or drop) in the source voltage. Indicates the time for replacing the lamp unit. Error is detected in the lamp or lamp power. Lighting in red Blinking in red (3 times) Temperature monitor TEMP Lamp monitor LAMP1 LAMP2
42 Cleaning and replacement of air filter If too much dust accumulates on the air filter, [AIR FILTER] appears at the lower left of the screen, and the temperature monitor (TEMP) will blink once. If even more dust is allowed to accumulate, the temperature inside the main unit will rise, the temperature monitor (TEMP) will blink twice, and the power is turned off. Clean the air filter section once every 100 hours or so as a guideline depending on the location of projector operation. It appears only for 30 seconds within 3 minutes after the power is turned on. It disappears if any of the buttons on the rear side of the main unit or on the remote control is pressed. Procedure of cleaning Turn off the main power and remove the power plug from the receptacle. Turn off the main power supply observing the procedure (Powering off the projector) on page 24 and then remove the power plug. Dismantle the air filter. There are two air filters, one at the left and one at the right. Use your finger to pull the air filter tab toward you, and remove it from the main unit. Set the air filter. Set the air filter in the reverse order to step . Clean the air filter. Suck off deposited dust with a vacuum cleaner. • Do not to suck in the air filter itself. • Do not rinse off the air filter with water. Doing so will impair the filter’s ability to provide protection from dust.Attention • Fit the air filters into place with the filter material facing the back. (The left and right filters have the same shape.) • The air filter must be fitted in place when using the projector. Using the projector without the air filter fitted inside, dirt and dust are sucked into the projector, causing failure.Attention • If cleaning cannot remove the dust completely, then it is a sign to replace the air filter. Consult the dealer. In addition, when the lamp unit is replaced, also replace the air filter. • Be absolutely sure to use the air filter specifically designed for use with the projector. Note Air filter
43 Replacing the lamp unit Precautions on lamp unit replacement Remove the power plug and confirm that the surroundings of the lamp unit have cooled off. Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled, explosion might result. A used lamp unit may burst if it is handled violently. For disposition of used lamps, request an industrial waste disposal contractor. Do not reset the cumulative time, except when the lamp unit has been replaced with a new unit. If you continue to use a lamp after the replacement time, the lamp may break. Phillips screwdriver is necessary when replacing a lamp unit. Take care not to slip your hand when using a screwdriver. • A lamp unit is an optional part. Contact the dealer. Replacement lamp unit model No.: ET-LAD55 (single bulb), ET-LAD55W (double bulbs) Rating: 300W Long life lamp unit model No.: ET-LAD55L (single bulb), ET-LAD55LW (double bulbs) Rating: 160W • Other lamps than specified above cannot be used. Be sure to use the specified lamp.Attention Timing of lamp unit replacement The lamp used for the light source has its due life. The life of light source lamp used in the main unit is 1 500 hours1(when “LAMP POWER” is “HIGH” and “LAMP SELECT” is “DUAL”). However, it may happen that the lamp becomes dead (will not light) by the time of 1 500 hours1depending on the characteristics of individual lamps and working conditions (lamps may reduce their life affected by the times of lighting and the intervals between previous lighting and next lighting). Therefore, it is strongly recommended for the user to keep a spare bulb. If your lamp unit is not replaced after 1 300 hours 2(with “LAMP POWER” set at “HIGH”), power supply will be turned off automatically at the time of 1 500 hours1, entering a standby state. After 1 500 hours1of initial lighting, power supply is turned off automatically about 10 minutes later, entering a standby state even if it is turned on again. Indication after 1 300 hours2(with “LAMP POWER” set at “HIGH”) When lamp unit used hours have reached 1 300 hours2, lamp monitor (LAMP1 or LAMP2) light up including standby state. Further, an on-screen indication will appear for about 30 seconds as shown in the diagram on the left, recommending replacement of lamp unit. (The indication on the left diagram will disappear after about 30 seconds or when either control button on the rear of main unit or remote control button is operated.) After the time of 1 500 hours 1, the on-screen indication will not disappear unless the menu (MENU) button is operated. REPLACE LAMP 1 This time period is 4 000 hours when long life lamp units are used. 2 This time period is 3 800 hours when long life lamp units are used. WARNING! When replacing the lamp, allow it to cool for at least one hour before handling it.
44 Replacing the lamp unit Lamp unit replacement steps • After 1 500 hours (4 000 hours when long life lamp units are used) of operating the same lamp, it is only possible to operate the unit for approximately 10 minutes. Steps to must be completed within 10 minutes.Attention Turn the power off by following the steps on page 24, remove the power plug and confirm that the surroundings of the lamp unit have cooled off. Check that the fan has stopped running. Have a Phillips screwdriver ready ahead of time. Remove the screw securing the lamp unit cover, and then slide the lamp unit cover a little toward the left, and remove it. Remove the two screws securing the fan unit. Lamp unit cover Open the fan unit as shown in the figure. Remove the screws securing the lamp units (two for each unit), take hold of the handles, and remove the lamp units. Install the new lamp unit. Use a Phillips screwdriver to securely tighten the 2 lamp unit fixing screws (two for each unit). Lamp unit 2 Handle Lamp unit 1 Lamp unit Fixing screws Secure the two screws for securing the fan unit tightly. Slide the cover a little toward the right, and secure it using the screw for securing the lamp unit cover tightly. • Firmly install the lamp unit and lamp unit cover. If not installed firmly, a protection circuit will function and the power will not be turned on.Attention • The lamp units are constructed in such a way that the screws in steps and will not fall through completely.Note Caution The lamp unit will be hot after it has been used. You might get burned if you touch it while it is still hot.
45 Insert the power cord plug into the wall outlet and then press the MAIN POWER switch. Press the “ I ” button so that a picture is projected onto the screen. Press the “MENU” button to display the MAIN MENU screen, and then press the and buttons to move the cursor to select “OPTION2”. Press the “ENTER” button to display the “OPTION2” screen, and select “SYSTEM INFORMATION” with the and buttons. Press the “ENTER” button. The SYSTEM INFORMATION screen will be displayed. Press and hold the “ENTER” button on the projector or the remote control for approximately 3 seconds. An item “LAMP TIME RESET” will be added. Select the lamp which has been replaced with the and buttons. LAMP1: Replace the LAMP UNIT 1 LAMP2: Replace the LAMP UNIT 2 Press the ENTER button, and when the “LAMP TIME RESET” display flashes, press the ENTER button again. The used hours of the specified lamp unit will be reset to zero. When more than one lamp has been replaced, repeat the procedure from step . • If the power does not turn on even after turning the MAIN POWER switch “I”, turn the MAIN POWER “O”, confirm that the lamp unit and door are installed correctly, and turn on again.Attention MENU PICTURE ADVANCED MENU OPTI0N2 TEST PATTERN OPTION1 POSITION LANGUAGE LAMP TIME RESET LAMP1 LAMP2 LAD55 LAD55L LAD55 1433h 0h 1100h 0h LAD55L SYSTEM INFORMATION ROM VERSION HIGH 200h TOTAL 300h LAMP2 LOW SET RUNTIME 300h LAMP1 LOW 100h 100h 1. 00. 00 • When the “LAMP TIME RESET” display flashes, the lamp time reset can be canceled by pressing the MENU button. • The used hours of the lamp units can also be reset to zero by taking the following action instead of steps to . When lamp unit 1 has been replaced: In the standby mode, press the number buttons in the sequence of 737381, and then press the ENTER button. When lamp unit 2 has been replaced: In the standby mode, press the number buttons in the sequence of 737382, and then press the ENTER button. When the used hours have been reset, the lamp monitor (LAMP1/LAMP2) will flash for 3 seconds.Note
46 Using Web Browser Control Accessing from the Web browser Start the web browser on your PC, then enter the IP address which was set in the projector. Enter “user1” in the user name field, then enter the password in the password field. The default setting is “panasonic” (all lower case). If you have changed the password, enter the new password here. The host name set in the projector is displayed in the “Realm” field. Click [OK]. The Basic Control page is displayed. Password change page Click [Change password]. • Avoid activating two or more Web browser simultaneously to work out setting or control actions. • Change the password first of all.Note This projector has networking functions which allow it to be controlled through a web browser on a PC. The controlled items are: • Projector’s settings and adjustment • Projector’s status display • Transmission of a E-mail message when the projector has a problem Old password input field New password input field New password input field (re-enter for confirmation) Button for executing password change Button for erasing all entered characters
47 Basic control page This page is the first page displayed when the projector is accessed through a web browser. To move from another page, click [Projector control], then [Basic control]. E-mail set up button Click this item, and an E-mail setting page appears. Monitor information button Click this item, and the status of the projector is displayed. Detail control page Click [Projector control], then [Detail control] to display the Detail control page. Pressing these buttons controls the projector and updates the on-screen description on the right of the control page when control is finished. On-screen status is displayed, even if the on-screen of projector is set to off. Temporary stop of video Lens adjustment Test pattern display This button updates the on-screen description on the right of the control page with the latest information. Control button Click this item, and a projector control page appears. OSD (On-screen Display) display/non- display Power On/Off control Shutter control Use these to select the input signals. Signal System Switching Network set up button Click this item, and a network set up page for IP address and other items appear. Change password button
48 Using Web Browser Control Error information page When is displayed on the status information screen, click it to display the error details. • Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.Note OK: Normal operation FAILED: Occurrence of trouble Monitor information page Click [Projector control], then [Status information] to display the Status information page. This page displays the projector statuses established for the items shown below. Displays the input switching status. Displays temperature of projector’s intake air. Displays temperature inside the projector. Displays the lamp1 lit hours. Displays the lamp2 lit hours. Displays used hours of the projector. Displays self-diagnosis information. Displays the type of projector. Displays the firmware version of the projector main unit. Displays temperature around the lamp.
49 When [FAILED] has appeared for an item Parameter MAIN CPU BUS FAN OPTICS MODULE TEMPERATURE INPUT AIR TEMPERATURE AROUND LAMP TEMPERATURE LAMP REMAIN TIME LAMP STATUS SHUTTER AIR FILTER OPTICS MODULE TEMP.SENSOR INPUT AIR TEMP.SENSOR AROUND LAMP TEMP. SENSOR BATTERY AIRFLOW SENSOR COLOR WHEEL Description Trouble has occurred in the microcomputer circuitry. Consult your dealer. Trouble has occurred in the fan or its drive circuit. Consult your dealer. The temperature inside the projector is high. It may be that the projector is being used where the ambient temperature is high such as near a heating appliance. The input air temperature is too high. It may be that the projector is being used where the ambient temperature is high such as near a heating appliance. The temperature near the lamp has risen very high. Something may be blocking the exhaust vent. The lamp runtime has exceeded the prescribed cumulative time, and it is now time to replace the lamp. The lamp has failed to light. Wait a short while for the lamp to cool off, and then turn on the power. Trouble has occurred in the shutter circuitry. Consult your dealer. Too much dust accumulates on the air filter. Turn off the MAIN POWER switch using the procedure on page 24 and clean the air filter (refer to page 42). Trouble has occurred in the temperature detection sensor inside the projector. Consult your dealer. Trouble has occurred in the sensor used to detect the input air temperature. Consult your dealer. Trouble has occurred in the temperature detection sensor around lamps. Consult your dealer. The backup battery has been run out. Consult your dealer. Trouble has occurred in the air volume sensor. Consult your dealer. Trouble has occurred in the color wheel or the color wheel drive circuit. Consult your dealer. The user can modify the threshold temperature for sending temperature warning mail. If the temperature rises above the set value, control sends temperature warning mail. E-mail setup page With this projector, if a problem occurs or if the lamp usage time reaches a set value, an e-mail message can be sent to one or more preset e-mail addresses (maximum two addresses). Click [Projector Control], then [E-mail set up] to display the E-mail setup page. Select “Enable” to use the E-mail function. Enter the IP address or server name of the E-mail server (SMTP). The DNS server must be set if the server name is entered. Enter the E-mail address of the projector. (maximum 63 characters) The user can enter the location of, for example, the installed projector so that the recipient may easily identify the originator of the E-mail. (maximum 63 characters) The user can modify the minimum time interval of temperature warning mail. The default value is 60 minutes. In this case, the user cannot send another mail for 60 minutes after sending previous temperature warning mail even the set warning temperature is reached again. (Continued on next page)
50 Using Web Browser Control Enter the E-mail address to which the E- mail is to be sent when two E-mail addresses are going to be used. Do not enter it when the second E-mail address is not going to be used. Check these boxes when E-mail is to be sent periodically to two E-mail addresses. E-mail will be sent at the times and on the days checked. E-mail setup page (Continuing) Select the conditions for sending E-mail. ERROR: an error is detected by self-diagnosis. LAMP RUNTIME:remaining lamp service time has reached the value set in the field. INPUT AIR TEMPERATURE: intake air temperature has reached the value set in the field. Periodic warning interval setting (e-mail is sent on the checked days of the week/times) Enter the E-mail address of your desired recipient. Select the conditions for sending the second E-mail. ERROR:an error is detected by self-diagnosis. LAMP RUNTIME:remaining lamp service time has reached the value set in the field. INPUT AIR TEMPERATURE: intake air temperature has reached the value set in the field. Button to update settings • Only alphanumeric characters, “.”, “_”, “-”, or “@” are available to set an e-mail address. Note