Page 31
Section 300-Installation Chapter 2. System Overview 576-13-300 DBS 576 (USA), issued 6/2/98 2-9 CPC576 card (VB-444301) The CPC576 card is a high-performance CPU unit for system with up to 576 ports. A 32-bit CPU is incorporated. The CPC576 card provides a 4-circuit MFR (DTMF receiver circuit), an input terminal for music on hold tone source (RCA jack), an interface connector for PCM- CIA (PC card interface connector) and modem (300 bps) functions. This card requires the use of the TSW576 card...
Page 32
Chapter 2. System Overview Section 300-Installation 2-10 DBS 576 (USA), issued 6/2/98 576-13-300 Table 2-6 shows the switch settings of the CPC576 and Table 2-7 shows the LED indications. Table 2-6. Switch settings of CPC576 card Table 2-7. LED indications of CPC576 cardSW No. Description SW1 : Black (MODE) Push switch for setting modes of system. SW2 : Red (RESET) Push switch for resetting. SW3 : (CODE) Rotary switch for setting startup mode of system. SW6 : (RAM HOLD) Switch for selecting battery...
Page 33
Section 300-Installation Chapter 2. System Overview 576-13-300 DBS 576 (USA), issued 6/2/98 2-11 TSW288 card (VB-444202) The TSW288 card is the time switch card for the CPC288 card. The TSW288 card is mounted on the option slot of the main cabinet. Only one TSW288 card can be mounted for each system (maximum 288 ports). When connecting to additional cabinets, this card is cabled to the CBL card (VB- 44451) installed into CPC card slot of the additional cabinet(s). The TSW288 card provides functions...
Page 34
Chapter 2. System Overview Section 300-Installation 2-12 DBS 576 (USA), issued 6/2/98 576-13-300 TSW576 card (VB-444302) The TSW576 card is the time switch card required for the system using a CPC-576 card. This card supports a maximum of 576 ports. The TSW576 card is mounted in the option 1 slot of the main cabinet. Only one TSW576 card can be mounted for each system. When connecting to additional cabinets, this card and CBL card (VB-44451) installed into CPC card slot of the additional cabinet are...
Page 35
Section 300-Installation Chapter 2. System Overview 576-13-300 DBS 576 (USA), issued 6/2/98 2-13 CBL card (VB-44451): Building Block card The CBL card is required for interconnecting cabinets in the DBS 576 system. The TSW288 or TSW576 card is also necessary for the interconnection of cabinets (building block connection). The CBL card must be mounted in the CPC slot of all cabinets other than the master cabinet. A dedicated interconnect cable pair connects between cabinets. The connection to the...
Page 36
Chapter 2. System Overview Section 300-Installation 2-14 DBS 576 (USA), issued 6/2/98 576-13-300 CBLDBS Card Kit (VB-44452): Connection Cable card-DBS The CBLDBS kit includes an interface card and cables for connecting between the DBS 576 and the DBS 96 cabinet and a new MDF interface card for the DBS. The TSW288 / TSW576 card is necessary for connecting a DBS 576 to a DBS 96 cabinet. The CBLDBS card must be mounted in the AUX1 slot of the DBS (AUX2 cannot be used). A dedicated cable connects this...
Page 37
Section 300-Installation Chapter 2. System Overview 576-13-300 DBS 576 (USA), issued 6/2/98 2-15 The CBLDBS interface card provides connection points between the DBS and the MDF. Figure 2-11. CBLDBS MDF card
Page 38
Chapter 2. System Overview Section 300-Installation 2-16 DBS 576 (USA), issued 6/2/98 576-13-300 EXT MDF card (VB-44611): Extension MDF Interface Card The EXT MDF card provides a standard 25-pair connection at the DBS 576 Cabinet. This interface board installs in one of five possible positions on either side of the DBS 576 Cabinet and supports up to three extension cards (either DEC/8 or AEC/8). Since each extension card contains 8 extension ports, the EXT MDF supports a maximum total of 24...
Page 39
Section 300-Installation Chapter 2. System Overview 576-13-300 DBS 576 (USA), issued 6/2/98 2-17 TRK MDF card (VB-44512): Trunk MDF Interface Card The TRK MDF card provides a standard 25-pair connection at the DBS 576 Cabinet. This interface board installs in one of five possible positions on either side of the DBS 576 Cabinet and supports up to three trunk cards (LTRK/8, LGTRK/8 or DIDTR/8). Since each of these trunk cards contains 8 extension ports, the TRK MDF supports a maximum total of 24...
Page 40
Chapter 2. System Overview Section 300-Installation 2-18 DBS 576 (USA), issued 6/2/98 576-13-300 SYNC Package (VB-44460): SYNC Package/Network Unit The SYNC package supplies a network synchronizing circuit, and is required when a digital circuit, such as ISDN, is used. The SYNC package generates a PCM clock that is synchronized with a digital network by the PLL circuit, supplying the PCM clock to the TSW288 / TSW576 card or CPC96 card. The SYNC package is mounted on either the CPC96 card or the...