Panasonic Cw Xc91yh Repair Manual
Here you can view all the pages of manual Panasonic Cw Xc91yh Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
ModelCW -XC91YH PhaseSingle Voltage240 - 220 V Frequency50 Hz Cooling Capacity2.67 - 2.64 kW 9,100 - 9,000 Btu/h Running Current4.3 - 4.4 A Input Power975 - 935 W EER2.74 - 2.82 W/W Starting Current16.9 A Compressor Output750 W Noise LevelIndoor (High / Low): 49 / 45 - 47 / 43 Outdoor (High / Low): 58 / 54 - 57 / 53 Moisture Removal1.6 Ltr/h 3.4 Pint/h © 2001 Matsushita Industrial Corp. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CW-XC91YH...
Page 2
1 Functions 2 2 Dimensions 4 3 Refrigeration Cycle Diagram 5 4 Block Diagram 5 5 Wiring Diagram 6 6 Air Conditioner Performance Evaluation 6 7 Troubleshooting Guide 7 8 Operation Details 8 9 Operating Instructions 11 10 How To Install 16 11 Care and Maintenance 20 12 Service Information 21 13 Exploded View 22 14 Replacement Part List 23 15 Electronic Circuit / Indicator Complete 24 16 Electronic Circuit / Main 24 17 Technical Data 25 18 Electronic Circuit...
Page 4
2 Dimensions 2.1. CW-XC91YH 2.1.1. Top View, Front View and Side View. ItemUnit: Inch (mm) A - Width17-23/32” (450) B - Height13-5/8” (346) C - Depth22-27/32” (580) D21-1/4” (540) E5-21/32” (144) F6-1/32” (153) G1-31/32” (50) H3-27/32” (98) I1-3/16” (30) J3-27/32” (98) K1-9/16” (40) L9-7/32” (234) M3-27/32” (98) N2-31/32” (75) O1-11/16” (43) P3-17/32” (90) Q0-29/32” (23) R10-11/32” (263) 4 CW-XC91YH
Page 5
3.1. CW-XC91YH3.2. CW-XC91YH ItemPressure (MPa)Temperature (°C) A2.00 ~ 2.2072 ~ 87 B1.95 ~ 2.1535 ~ 45 C0.54 ~ 0.607~13 D0.51 ~ 0.579~17 Note: Indoor temperature at 27°C (DB), 19°C(WB) andOutdoor at 35°C (DB), 24°C(WB). 3 Refrigeration Cycle Diagram 4 Block Diagram 4.1. CW-XC91YH 5 CW-XC91YH
Page 6
5.2. Resistance of Fan Motor windings and the rated Capacitor. ModelCW-XC91YH ConnectionCWA921091 Blue - Yellow78.7Ω Yellow - Brown8.18Ω Brown - Orange57.1Ω Red - Yellow117.2Ω 5.3. Resistance of Compressor windings and the rated Capacitor. ModelCW-XC91YH Connection2PS156D5EA02 C-R3.597Ω C-S4.868Ω CapacitorDS371306CPNA (25µF, 370VAC) Note: Resistance at 20°C of Ambient Temperature. 5 Wiring Diagram 5.1. CW-XC91YH 6 Air Conditioner Performance Evaluation Suction & Discharge Air Temperature...
Page 7
7 Troubleshooting Guide Warning: Disconnect unit from electrical powersupply before making any electrical checks. TroubleCheckResultCauseRemedy Fan Motor and Compressor won’t run. • • • • Supply Voltage • • • • Fuse Box or Circuit Breaker. • • • • Power cord orWiring Harness. • • • • Temp. Setting. • • • • Less than 10% by Rated. • • • • Open Contacts. • • • • Pulled loose or Shorted. • • • • Higher than ROOM TEMP. • • • • Customer...
Page 8
8 Operation Details 8.1. Fan Mode Operation • • • • Fan operation only. Fan in operation according to Remote Control or Main Unit (Touch Control Panel) setting. 8.1.1. Manual Setting of Fan Speed • • • • Basic Fan Speed can be manually adjusted (Lo or Hi) by using the Fan Speed Selection Button/Pad at Remote Control or Main Unit (Touch Control Panel). 8.2. Cooling Mode Operation • • • • Cooling in operation according to Remote Control or Main Unit (Touch Control Panel) setting....
Page 9
8.2.6. Cooling Operation Time Diagram 8.3. Powerful Operation • • • • Purpose of this operation is to obtain the setting temperature quickly. • • • • W hen the Powerful is set during Cooling Operation, the set temperature will be automatically decreased 3°C against the present setting temperature (Lowest limit temperature: 16°C). • • • • This operation automatically will be running under Super High Fan Speed. • • • • Sound emitted by the unit will be increased during...
Page 10
8.5. Fan Speed Control • • • • Manual Fan Speed Control Basic fan speed adjustment (2 setting, from Lo to Hi) can be carried out by using the Fan Speed Selection Button/Pad at the Remote Control or Main Unit (Touch Control Panel). 8.6. Airflow Direction Control 8.6.1. Horizontal Airflow Direction When AirSwing Button/Pad is pressed with Remote Control or Main Unit (Touch Control Panel) in the Auto Airflow, the airflow direction louver swings side to side within the full swing range as shown in...