Panasonic Cw Xc70ja Cw Xc90ja Repair Manual
Here you can view all the pages of manual Panasonic Cw Xc70ja Cw Xc90ja Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
1 Functions 2 2 Product Specifications 4 3 Dimensions 5 4 Refrigeration Cycle Diagram 6 5 Block Diagram 6 6 Wiring Diagram 7 7 Air Conditioner Performance Evaluation 7 8 Troubleshooting Guide 8 9 Operation Details 10 10 Operating Instructions 13 © 2002 Matsushita Industrial Corp. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CW-XC70JA CW-XC90JA 11 Installation Instructions 18 12 Care and Maintenance 21 13 Servicing...
Page 4
2 Product Specifications UnitCW-XC70JACW-XC90JA PhaseØSingleSingle VoltageV220220 FrequencyHz5050 Cooling CapacitykW Btu/h2.06 7,0002.64 9,000 Running CurrentA3.84.4 Input PowerW730935 EERBtu/hW9.69.6 Starting CurrentA15.215.5 Compressor OutputW550750 Fan Motor OutputW5151 Noise LevelIndoor (High / Low)db(A)46 / 3746 / 39 Outdoor (High / Low)db(A)55 / 5056 / 53 Moisture RemovalL/h Pt/h1.3 2.71.6 3.4 Air CirculationIndoorm3/min (ft3/min)7.3 (258)7.3 (258) Outdoorm3/min (ft3/min)11.3 (399)11.3 (399)...
Page 5
3 Dimensions 3.1. Top View, Front View and Side View 3.2. Unit ItemUnit: Inch (mm) A - Width17-23/32” (450) B - Height13-10/16” (346) C - Depth22-27/32” (580) D11-9/16” (293) E1-15/32” (37) F10-14/16” (276) G11-9/16” (293) 5
Page 6
4 Refrigeration Cycle Diagram ModelCW-XC70JACW-XC90JA ItemPressure (MPa)Temperature (°C)Pressure (MPa)Temperature (°C) A1.84 ~ 2.0461 ~ 761.95 ~ 2.1568 ~ 83 B1.68 ~ 1.8835 ~ 451.79 ~ 1.9935 ~ 45 C0.60 ~ 0.669~150.54 ~ 0.607~13 D0.57 ~ 0.6310 ~ 180.51 ~ 0.578~16 Note: Indoor temperature at 27°C (DB), 19°C(WB) and Outdoor at 35°C (DB),24°C (WB)forCooling. 5 Block Diagram 6
Page 7
6 Wiring Diagram 6.1. Resistance of Fan Motor windings and the rated Capacitor ModelCW-XC70JA & CW-XC90JA ConnectionCWA921154 Blue - Yellow98.1Ω Yellow - Orange18.5Ω Brown - Yellow97.4Ω Red - Yellow125.8Ω 6.2. Resistance of Compressor windings and the rated Capacitor ModelCW-XC70JACW-XC90JA ConnectionCWB09759CWB09758 C-R5.193Ω3.501Ω C-S5.557Ω3.405Ω CapacitorCWA312074 (20µF, 370VAC)CWA312076 (30µF, 370VAC) Note: Resistance at 20°C of Ambient Temperature. 7 Air Conditioner Performance Evaluation Suction &...
Page 8
8 Troubleshooting Guide Warning: Disconnect unit from electrical power supply before making any electrical checks. TroubleCheckResultCausesRemedy Fan Motor and Compressor won’t run. • Supply Voltage • Fuse Box or Circuit Breaker. • Power cord or Wiring Harness. • Temperature Setting. • Less than 10% by Rated. • Open Contacts. • Pulled loose or Shorted. • Higher than room temperature • Temporary or Permanent? • Customer Restarted unit immediately without waiting 3 minutes. • Consult ELECTRICIAN, if...
Page 9
TroubleCheckResultCausesRemedy Insufficient cooling. • Temperature Setting. • Ventilation door open. • Air filter dirty. • Location of installation. • Evaporator/Conden ser Coil obstructed. • Unit capacity for the room too small. • Temperature difference and running current. • Higher than room temperature. • Open. • Clogged or dirty. • Sunlight hitting outdoor side. • Obstacles. • Clogged or dirty. • Not satisfied. • REFER TO PERFORMANCE EVALUATION. • Reduces capacity. • Restricted air...
Page 10
9 Operation Details 9.1. Fan Mode Operation • Fan operation only. Fan inoperation according to Remote Control or Main Unit (Touch Control Panel) setting. 9.1.1. Manual Setting of Fan Speed • Basic Fan Speed can be manually adjusted (Lo or Hi) byusing the Fan Speed Selection Button/Pad at Remote Control or Main Unit (Touch Control Panel). 9.2. Cooling Mode Operation • Cooling in operation according to Remote Control or Main Unit (Touch Control Panel) setting. 9.2.1. Time Delay Safety Control (3...