© Panasonic Corporation 2015. Order No: PAPAMY1501049CE Indoor Unit CS-E9RKUAW CS-E12RKUAW CS-E18RKUAW CS-E24RKUAW Destination USA Canada Please file and use this manual together with the service manual for Model No. CU-2E18NBU and CU-5E36QBU, Order No. PHAAM1111120A1 and PAPAMY1312037CE. AU COMMOPO QUITEMOF TI SE CAN ON OF12AIFA SAC ECO FA S AI SWAU HEAT CO DR FA /TEMPOFF/ TISETCANONOFF123CHE AU COMMOPO QUITEMOF TI SE CAN ON OF1 23FA SAC ECO AU HEAT CO DR FAFA S AI SW AI/TEMPOFF/...
Page 2
49 13. Operation Control 13.1 Basic Function Inverter control, which equipped with a microcomputer in determining the most suitable operation mode as time passes, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operation mode, the microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature shifting. The compressor at outdoor unit is operating following the frequency instructed by the...
Page 3
50 13.1.4.2 Automatic Operation (For Single Split Connection Only) š This mode can be set using remote control and the operation is decided by remote control setting temperature, remote control operation mode and indoor intake air temperature. š During operation mode judgment, indoor fan motor (with speed of Lo-) is running for 30 seconds to detect the indoor intake air temperature. š Every 10 minutes, the indoor temperature is judged. š For the 1st judgment o If indoor intake temperature -...
Page 4
51 13.3 Indoor Fan Motor Operation 13.3.1 Basic Rotation Speed (rpm) š Manual Fan Speed [Cooling, Dry] o Fan motor’s number of rotation is determined according to remote control setting. Remote control | | | | | Tab Hi Me+ Me Me- Lo [Heating] o Fan motor’s number of rotation is determined according to remote control setting. Remote control | | | | | Tab Shi Me+ Me Me- Lo š Auto Fan Speed [Cooling, Dry] o According to room temperature and setting temperature, indoor...
Page 5
52 13.5 Airflow Direction š There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes). š Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using remote control). 13.5.1 Vertical Airflow 13.5.1.1 CU-E9RKUA CU-E12RKUA Operation Mode Airflow Direction Vane angle (°) 1...
Page 6
53 13.5.3 Horizontal Airflow (CU-E18RKUA CU-E24RKUA) š Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below. Operation Mode Vane Angle (°) Heating with heat exchanger temperature A 68 ~ 112 B 90 Cooling and Soft Sry 68 ~ 112 š Manual vertical airflow direction can be set using remote...
Page 7
54 13.7 Quiet Operation (Heating) š Purpose o To provide quiet heating operation compare to normal operation. š Control condition o Quiet operation start condition ƒ When “POWERFUL/QUIET” button at remote control is pressed. Quiet LED illuminates. o Quiet operation stop condition ƒ When one of the following conditions is satisfied, quiet operation stops: š Stop by OFF/ON button. š Timer “off” activates. š POWERFUL/QUIET button is pressed again. ƒ When quiet operation is stopped,...
Page 8
55 13.10 Auto Restart Control š When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after power supply resumes. š This type of control is not applicable during ON/OFF Timer setting. 13.11 Indication Panel LED POWER TIMER QUIET POWERFUL AUTO COMFORT ECONAVI Color Green Orange Orange Orange Green Green Light ON...
Page 9
56 2. Circuit Abnormal (Fix Output Lo) a. Abnormal judgment start condition. After ECONAVI and AUTO COMFORT Sensor unit power ON, and after pressed 70 seconds. b. Control content. Judge ECONAVI and AUTO COMFORT Sensor power level every 100ms. c. Abnormal Judgment condition. When ECONAVI and AUTO COMFORT Sensor has continues at Lo level for 25 seconds. 3. Abnormal treatment Any one of the above self-diagnosis result is abnormal š Abnormal counter +1 and ECONAVI and AUTO COMFORT...
Page 10
57 š ECONAVI Start condition. ƒ Press ECONAVI button. š ECONAVI Stop condition. ƒ Press ECONAVI button again. ƒ OFF Timer activates. ƒ Press OFF/ON button to turn off the air conditioner. ƒ Press AUTO OFF/ON button to turn off the air conditioner. ƒ Press POWERFUL/QUIET button. š AUTO COMFORT Start condition. ƒ Press AUTO COMFORT button. š AUTO COMFORT Stop condition. ƒ Press AUTO COMFORT button again. ƒ OFF Timer activates. ƒ Press OFF/ON button to turn off the air...