Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual
Here you can view all the pages of manual Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
1 SERVICE INFORMATION 2 2 FEATURES 3 3 SPECIFICATION (HEAT PUMP TYPE) 9 4 SPECIFICATION (COOLING ONLY TYPE) 14 5 TECHNICAL DRAWING 20 6 CIRCUITDIAGRAM 26 7 OPERATING INSTRUCTION 42 8 REFRIGERATION CYCLE 44 9 OPERATIO N RANGE 47 10 PIPE LENGTH 48 11 OPERATING CHARACTERISTIC 50 12 FAN PERFORMANCE 51 13 SAFETYDEVICE 54 14 COMPONENT SPECIFICATION 55 © 2002 Matsushita Air-Conditioning Corp. Sdn. Bhd. (183914D). All rights reserved. Unauthorized copying and distribution is a...
Page 2
1 SERVICE INFORMATION Notice of Address setting for NEW Cassette / NEW Outdoor Unit. The new Ceiling / New Outdoor models are possible to have address setting fortwin / triplecontrol or group control by automatic when main powersupply is switched on. (Manual address setting is also possible by using Dip switch on Indoor unit P.C. board.) However,this address setting isonly possible when made proper wiring connection and also Indoor unit should be original virgin unit . 1.1. Example of trouble at test...
Page 3
2.1. Variety of excellent features 2.1.1. Compact design • • • • The height is only 29cm (2.5 HP model and 3 HP model) and can be installe d even where the space is limited. 2.1.2. Automatic restart function • • • • W hen the electric power comes back after a power failure, the unit itself automatically restarts the operation in the pre- failure mode. 2.1.3. Auto fanmode (indoor unit) • • • • Auto fan mode is added beside s Hi, Me and Lo. It automatically adjusts the fan speed...
Page 4
[Product features] 2.2.1. Low-noise design improves in surrounding areas 1. The noise-suppressing winglet fan is a result of new research into vane design theory. The unique curved shape suppresses the generation of vortexes, thus reduces air flow noise. 2. The adoption of double -orifice rings reduces air passage resistance. 3. Strengthening of the noise insulation materials in the compressor and the sealing-in of mechanical noise allows vibration noise to be greatly enclosed and suppressed. 4. The...
Page 5
2.3.1. Pipes that are one size larger can also be connected for renewal • • • • If renewing the system, existing refrigerant pipes can be utilized so that only the indoor units need to be replaced. • • • • For example, liquid and gas pipesfrom 10years ago can be connected to current pipes with the same size for one size larger. Effective utilization of materials reduces working time and trouble. (Adaptor sockets are not supplie d.) 2.3.2. Additional refrigerant charging unnecessary for...
Page 6
2.4.2. Separate indoor/outdoor unit power supplies The power supply can be connected to (1) just the outdoo r units, or (2) to both indoor and outdoor units. 2.4.5. Twin operation • • • • Simultaneous air conditioning of wide spaces and corners is possible. Indoor units of different horsepowers and models can even be used in combination. • • • • Master unit and slave-units can be set automatically in twin systems. No address setting is necessary. • • • • Multiple indoor units...
Page 7
• • • • W hen storing pipes, seal both ends of the pipes and store them indoors to prevent water, dust and other foreign particles from getting inside. • • • • Take care not to let any foreign particles (oxide scales, water or dirt) get inside the refrigerant lines (same as for R22). Refrigerant pipe storing LocationInstallation periodStoring method Outdoors1 month or morePinching Less than 1 monthPinching or taping IndoorsAny • • • • Pinching method Close off the ends of the...
Page 8
14. Test operation and adjustment. 15. Organize documentatio n before handover. 16. Hando ver and explan ation of operation. • • • • Ventilation of closed rooms R407C is a non-fla mmable refrigerant with low toxicity ,but in the gas state its specific gravity is heavier than that of air, and so if leaks occur in a closed room, suffoca tion may occur. Toxic gases may also be generated if it comes into direct contact with flames, so adequate ventilation must be provided. 8
Page 9
3 SPECIFICATION (HEAT PUMP TYPE) 3.1. CS-W24BD2P / CU-W24BBP5 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W24BD2PCU-W24BBP5 Cooling CapacitykW6.30 (BTU/h)(21,500) Heating CapacitykW7.10 (BTU/h)(24,200) Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/minHi 18 cfmHi 636 External Static PressuremmAqHi 10- PaHi 98 Air InletBackward SuctionBack sided Suction Air OutletFront blow-outFront blow-out Outside Dimension (H x W x D)mm290 x (1000 + 100) x 500900 x 900 x 320 Net Weightkg (lbs)43...
Page 10
3.2. CS-W28BD2P / CU-W28BBP5 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W28BD2PCU-W28BBP5 Cooling CapacitykW7.10 (BTU/h)(24,200) Heating CapacitykW8.00 (BTU/h)(27,300) Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/minHi 20 cfmHi 706 External Static PressuremmAqHi 10- PaHi 98 Air InletBackward SuctionBack sided Suction Air OutletFront blow-outFront blow-out Outside Dimension (H x W x D)mm290 x (1000 + 100) x 500900 x 900 x 320 Net Weightkg (lbs)43 (95)81 (181) Piping...