Home > Panasonic > Air Conditioner > Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual

Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual

Here you can view all the pages of manual Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

 1 SERVICE INFORMATION 2
 2 FEATURES 
3
 3 SPECIFICATION (HEAT PUMP TYPE) 
9
 4 SPECIFICATION (COOLING ONLY TYPE) 
14
 5 TECHNICAL DRAWING 
20
 6 CIRCUITDIAGRAM 
26
 7 OPERATING INSTRUCTION 
42
 8 REFRIGERATION CYCLE 
44
 9 OPERATIO N RANGE 
47
 10  PIPE LENGTH 
48
 11  OPERATING CHARACTERISTIC 
50
 12  FAN PERFORMANCE 
51
 13  SAFETYDEVICE 
54
 14  COMPONENT SPECIFICATION 
55
© 2002 Matsushita Air-Conditioning Corp. Sdn. Bhd.
(183914D). All rights reserved. Unauthorized copying
and distribution is a...

Page 2

1 SERVICE INFORMATION
Notice of Address setting for NEW Cassette / NEW Outdoor Unit.
The new Ceiling / New Outdoor models are possible to have address setting fortwin / triplecontrol or group control by
automatic when main powersupply is switched on.
(Manual address setting is also possible by using Dip switch on Indoor unit P.C. board.) However,this address setting isonly
possible when made proper wiring connection and also Indoor unit should be original virgin unit
.
1.1. Example of trouble at test...

Page 3

2.1. Variety of excellent features
2.1.1. Compact design
 
    • 
• •  • 
The height is only 29cm (2.5 HP model and 3 HP model)
and can be installe d even where the space is limited.
2.1.2. Automatic restart function
 
    • 
• •  • 
W hen the electric power comes back after a power failure,
the unit itself automatically restarts the operation in the pre-
failure mode.
2.1.3. Auto fanmode (indoor unit)
 
    • 
• •  • 
Auto fan mode is added beside s Hi, Me and Lo.
It automatically adjusts the fan speed...

Page 4

[Product features]
2.2.1. Low-noise design improves in
surrounding areas
 1. The noise-suppressing winglet fan is a result of new
research into vane design theory. The unique curved shape
suppresses the generation of vortexes, thus reduces air
flow noise.
 2. The adoption of double -orifice rings reduces air passage
resistance.
 3. Strengthening of the noise insulation materials in the
compressor and the sealing-in of mechanical noise allows
vibration noise to be greatly enclosed and suppressed.
 4. The...

Page 5

2.3.1. Pipes that are one size larger can
also be connected for renewal
 
    • 
• •  • 
If renewing the system, existing refrigerant pipes can be
utilized so that only the indoor units need to be replaced.
 
    • 
• •  • 
For example, liquid and gas pipesfrom 10years ago can be
connected to current pipes with the same size for one size
larger. Effective utilization of materials reduces working
time and trouble. (Adaptor sockets are not supplie d.)
2.3.2. Additional refrigerant charging
unnecessary for...

Page 6

2.4.2. Separate indoor/outdoor unit
power supplies
The power supply can be connected to (1) just the outdoo r
units, or (2) to both indoor and outdoor units.
2.4.5. Twin operation
 
    • 
• •  • 
Simultaneous air conditioning of wide spaces and corners is
possible. Indoor units of different horsepowers and models
can even be used in combination.
 
    • 
• •  • 
Master unit and slave-units can be set automatically in twin
systems. No address setting is necessary.
 
    • 
• •  • 
Multiple indoor units...

Page 7

 
    • 
• •  • 
W hen storing pipes, seal both ends of the pipes and
store them indoors to prevent water, dust and other
foreign particles from getting inside.
 
    • 
• •  • 
Take care not to let any foreign particles (oxide scales,
water or dirt) get inside the refrigerant lines (same as for
R22).

Refrigerant pipe storing
LocationInstallation periodStoring method
Outdoors1 month or morePinching
Less than 1 monthPinching or taping
IndoorsAny
 
    • 
• •  • 
Pinching method
Close off the ends of the...

Page 8

 14. Test operation and adjustment.
 15. Organize documentatio n before handover.
 16. Hando ver and explan ation of operation.
 
    • 
• •  • 
Ventilation of closed rooms
R407C is a non-fla mmable refrigerant with low toxicity ,but in the gas state its specific gravity is heavier than
that of air, and so if leaks occur in a closed room,
suffoca tion may occur. Toxic gases may also be
generated if it comes into direct contact with flames, so
adequate ventilation must be provided.
8 

Page 9

3 SPECIFICATION (HEAT PUMP TYPE)
3.1. CS-W24BD2P / CU-W24BBP5
ITEM / MODELIndoor UnitOutdoor unit
Main BodyCS-W24BD2PCU-W24BBP5
Cooling CapacitykW6.30
(BTU/h)(21,500)
Heating CapacitykW7.10
(BTU/h)(24,200)
Refrigerant Charge-lessm30
Standard Air Volume for High Speedm3/minHi 18
cfmHi 636
External Static PressuremmAqHi 10-
PaHi 98
Air InletBackward SuctionBack sided Suction
Air OutletFront blow-outFront blow-out
Outside Dimension (H x W x D)mm290 x (1000 + 100) x 500900 x 900 x 320
Net Weightkg (lbs)43...

Page 10

3.2. CS-W28BD2P / CU-W28BBP5
ITEM / MODELIndoor UnitOutdoor unit
Main BodyCS-W28BD2PCU-W28BBP5
Cooling CapacitykW7.10
(BTU/h)(24,200)
Heating CapacitykW8.00
(BTU/h)(27,300)
Refrigerant Charge-lessm30
Standard Air Volume for High Speedm3/minHi 20
cfmHi 706
External Static PressuremmAqHi 10-
PaHi 98
Air InletBackward SuctionBack sided Suction
Air OutletFront blow-outFront blow-out
Outside Dimension (H x W x D)mm290 x (1000 + 100) x 500900 x 900 x 320
Net Weightkg (lbs)43 (95)81 (181)
Piping...
Start reading Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual

Related Manuals for Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual

All Panasonic manuals