    							24
    TROUBLESHOOTING (BEFORE CALLING FOR SERVICE)
    If your air conditioner does not work properly, first check the following points before requesting service. If it still does not
    work properly, contact your dealer or service center.
    OPERATING RANGE
    The air conditioner is operable within the temperature ranges as listed below: 
    Trouble Possible Cause Remedy
    Air conditioner does not run at all. 1.  Power failure.  1. Restore power.
    2. Leakage circuit breaker tripped.
    2. Contact service center.
    3. Line voltage is too low. 3. Consult your electrician or dealer.
    4.  Batteries in remote controller have 
    run down.4. Replace batteries.
    OPERATION lamp blinks and air 
    conditioner does not operate.Trouble in system. Contact service center.
    Compressor runs but soon stops. Obstruction in front of condenser coil.
    (Outdoor Unit)Remove obstruction.
    Poor cooling performance. 1.  Dirty or clogged air filter. 1.  Clean air filter to improve airflow.
    2.  Heat source or many people in room. 2.  Eliminate heat source if possible.
    3.  Doors and/or windows are open. 3.  Shut them to keep the heat out.
    4.  Obstacle near air intake or air 
    discharge port.4.  Remove it to ensure good airflow.
    5.  Thermostat is set too high for cooling. 5.  Set the temperature lower.
    Clicking sound is heard from the air 
    conditioner.In cooling operation, any plastic parts 
    may shrink due to a sudden 
    temperature change. In this event, a 
    clicking sound may occur.This is normal, and the sound will soon 
    disappear.
    OPERATION lamp lights but outdoor 
    unit will not run.The use of cellular phones near the air 
    conditioner may cause disturbance to 
    its normal operation.1.  Turn off the power then restart the 
    air conditioner after a while.
    2.  Consult your dealer.
    Temperature  Indoor air temperature  Outdoor air temperature
    COOLING Max.  95 °F DB / 71 °F WB  115 °F DB
    Min.  67 °F DB / 57 °F WB  14 °F DB 
    						
    							25
    SPECIFICATIONS
    Model No.Indoor Unit
    Single-phase, 208-230 V, 60 Hz
    Heating Capacity
    Operation
    Sound
    Unit Dimensions (H×W×D)
    (Indoor unit : Include panel)
    Net Weight Power Source
    Cooling CapacitykW
    BTU/h
    kW
    BTU/h
    inch(mm)
    lbs.(kg)
    Cooling Operation (H/M/L)
    Heating Operation (H/M/L)dB(A)
    dB(A)CS-MKS18NKU
    41/38/34
    - -
    17,5005.15
    -
    11-23/32×41-15/16×8-5/8
    (298×1,065×219)
    26.5(12.0)CS-MKS24NKU
    44/41/38
    - -
    24,2007.10
    -
    11-23/32×41-15/16×8-5/8
    (298×1,065×219)
    26.5(12.0)
    Model No.Outdoor Unit
    CU-4KS24NBU CU-3KS19NBU
    Single-phase, 208-230 V, 60 Hz
    Heating Capacity
    Operation
    Sound
    Unit Dimensions (H×W×D)
    Net Weight Power Source
    Cooling CapacitykW
    BTU/h
    kW
    BTU/h
    inch(mm)
    lbs.(kg)
    Cooling Operation (Hi)
    Heating Operation (Hi)dB(A)
    dB(A)50
    - -
    18,800 [ 9,800 ~ 18,800 ]5.50 [ 2.90 ~ 5.50 ]
    -
    29-1/8×35-7/16×12-19/32
    (740×900×320)
    138.9(63.0)50
    - -
    25,400 [ 9,800 ~ 25,400 ]7.50 [ 2.90 ~ 7.50 ]
    -
    29-1/8×35-7/16×12-19/32
    (740×900×320)
    138.9(63.0)53
    - -
    30,600 [ 9,800 ~ 30,600 ]9.00 [ 2.90 ~ 9.00 ]
    -
    35-1/32×35-7/16×12-19/32
    (890×900×320)
    174.2(79.0) CU-4KS31NBU 
    						