4.2. Outdoor Unit 4.2.1. CU-A9DKA 4.2.2. CU-A12DKA 11 CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA /
5 Refrigeration Cycle Diagram 12 CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA /
6 Block Diagram 13 CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA /
7 Wiring Diagram 15 CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA /
8 Operation Details 8.1. Heating Operation • Heating operation can be set using remote control. • This operation is applied to warm the room temperature reaches the setting temperature set on the remote control. • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C to 30°C. • During heating operation, the compressor will stoprunning and restart as shown in below figure. 8.1.1. Heating Operation Time Diagram 17 CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA /
8.2. Cooling Operation • Cooling operation can be set using remote control. • This operation is applied to cool down the room temperature reaches the setting temperature set on the remote control. • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C to 30°C. • During cooling operation, the compressor will stoprunning and restart as shown in below figure. 8.2.1. Cooling Operation Time Diagram 18 CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA /
8.3.1. Soft Dry Operation Time Diagram 8.3. Soft Dry Operation • Soft Dry operation can be set using remote control. • Soft Dry operation is applied to dehumidify and to perform a gentle cooling to the room. • This operation starts when the intake air temperature sensor reaches the setting temperature on the remote control. • W hen operation begins, Soft Dry will be switched “ON” for a maximum 10 minutes, then Soft Dry operation will be turned “OFF” for a minimum 6 minutes. After that, the Soft Dry operation will be “ON” and “OFF” based on the setting temperature as shown in below figure. • However after 3 minutes of compressor off, duringSoft Dry “OFF” (within 6 minutes Soft Dry restart control), the indoor unit will start to operate at normal Cooling mode if the intake temperature is higher than Cooling “ON” point. 19 CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA /
8.4. Automatic Operation • Automatic operation can be set using remote control. • This operation starts to operate with indoor fan at SLo speed for 25 seconds to judge the intake air temperature. • After judged the temperature, the operation mode is determined by referring to the below standard. • Then, the unit start to operate at determined operation mode, until it is switched off using remote control, with the setting temperature as shown in below table. • Operation mode will be determine again for judgement after 1 hour of operation, if the room temperature reaches to set temperature and compressor off time is over7 minutes 30 seconds continuously. The present operation mode will be continued, if the room temperature does not reach to set temperature (Compressor keeps running) eventhough after 1 hour from automatic operation mode started. PresentJudgementNext Mode ModeCoolingSoft DryHeating OO Cooling23°CCooling(Judgement:Not Applicable(Judgement: Heating23°C & Above)Below 23°C) OO Soft Dry20°CSoft DryNot Applicable(Judgement:(Judgement: Heating20°C & Above)Below 20°C) OO HeatingCooling(Judgement:Not Applicable(Judgement: 25°CHeatingAbove 25°C)25°C & below) Automatic Set Temperature Refer as below. • Automatic Set Temperature For each operation, set temperature will automatically set as shown below. However it can be selected 2°C higher or 2°C lower from standard set temperature by pressing the “Room Temperature Setting button”. OperationHi(Standard)Lo (+2°C)(±0°C)(-2°C) Cooling27°C25°C23°C Soft Dry24°C22°C20°C Heating23°C21°C19°C • The setting temperature for all the operations can be changed one level up or one level down from the standard temperature as shown in below table by pressing on the temperature up or temperature down button at remote control. 20 CS-A9DKACU-A9DKA / CS-A12D KA CU-A12D KA /