Have a look at the manual Panasonic Cs A18gkd Cs A18gkd Cu A18gkd Cu A24gkh Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
51 14 Troubleshooting Guide 14.1. Refrigeration Cycle System In order to diagnose malfunctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan. The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions, the standard values for them are shown in the table on the right.
52 14.1.1. Relationship between the condition of the air conditioner and pressure and electric current • Carry out the measurements of pressure, electric current, and temperature fifteen minutes after an operation is started. 14.1.2. Diagnosis methods of a malfunction of a compressor and 4-Way Valve Cooling Mode Heating Mode Low Pressure High PressureElectric current during operatingLow Pressure High PressureElectric current during operating Condition of the air conditioner Insufficient refrigerant (gas leakage) Clogged capillary tube or Strainer Short circuit in the indoor unit Heat radiation deficiency of the outdoor unit Inefficient compression Nature of fault Symptom Insufficient compressing of a compressor• Electric current during operation becomes approximately 20% lower than the normal value. • The discharge tube of the compressor becomes abnormally hot (normally 70 to 90°C). • The difference between high pressure and low pressure becomes almost zero. Locker compressor• Electric current reaches a high level abnormally, and the value exceeds the limit of an ammeter. In some cases, a breaker turns off. • The compressor has a humming sound. Insufficient switches of the 4-way valve• Electric current during operation becomes approximately 80% lower than the normal value. • The temperature different between from the discharge tube to the 4-way valve and from suction tube to the 4-way valve becomes almost zero.
53 15 Disassembly and Assembly Instructions 15.1. Indoor Electronic Controllers and Control Board Removal Procedures WARNING • Cautions! When handling electronic controller, be careful of electrostatic discharge. • Be sure to return the wiring to its original position. • There are many high voltage components within the heat sink cover so never touch the interior during operation. Wait at least two minutes after power has been turned off.
56 15.2. Indoor Fan Motor and Cross Flow Fan Removal Procedures
58 16 Technical Data 16.1. Thermostat Characteristics