Have a look at the manual Panasonic Cordless Impact Driver/Cordless Impact Wrench EYFLA1A, EYFLA2A, EYFLA2Q, EYFLA3J Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
- 11 - • You can select from 30 torque clutch settings (1 to 30). • Use figures from the Tightening Torque Chart to guide your selection of torque clutch setting. (See the following tighten-ing torque chart) . Press the OK button to accept the select -ed torque clutch setting. • The control panel will stop flashing and light up. CAUTION: • You must press the OK button in order for the selected setting to take effect. • Be sure to verify the new value after changing the setting. (See page 11.) Tightening Torque Chart (for Reference Use) The values illustrated on this chart were mea-sured under the conditions described below and are provided for reference purposes. Actual tightening torque varies with ambient conditions (the particular bolt being tightened, hardware being used, method of holding the bolt in place, etc.). 0 10 20 30 40 50 60 EYFLA1 (M6) EYFLA2 (M6)EYFLA1 (M8) EYFLA2 (M8) EYFLA3 (M8) EYFLA3 (M10) N • m 1 23 45 67 89 10 1112 13 1415 16 1718 19 20 2122 23 2425 262728 29 30 Measurement conditions • Temperature: Room temperature ( 0°C/68°F) Using the Interval Set • The interval set op erates to prevent the tool from operating after it automat ically stops as a result of the torque control fun ction, even if the switch is engaged. 1. Set the tool to configuration mode. (See page 10.) . Press the interval set button. • The control panel will begin flashing. Display: The number 0 flashes on and off.Battery indication lamp: The middle bar of the battery flashes on and off. Display Battery indication lamp 3. Press the and buttons to set the desired time. ButtonsDisplaySeconds 303 10.1 0Off 4. Press the OK button to accept the select -ed setting. • The control panel will stop flashing and light up, and the torque clutch setting will be displayed. CAUTION: • Be sure to verify the new value after changing the setting. Initializing All Settings Factory settings • Torque clutch setting: “F” (torque con -trol function off) • Interval setting: 0 (off) • This section explains how to revert all tool settings to their default values at the time of shipment from the factory. • The error display will be turned off. 1. Set the tool to configuration mode. (See page 10.) . Press the format button. • The control panel will begin flashing. Display: The letter “F” flashes on and off.Battery indication lamp: The upper and lower bars of the battery flash on and off. Display Battery indication lamp
- 1 - 3. Press the OK button to accept the select-ed setting. • The control panel will stop flashing and light up. Checking Tool Settings • This section describes how to have the tool display current settings for approx-i m a t e l y 3 s e c o n d s w h e n t h e t o o l i s stopped. • You cannot check tool settings when the control panel is turned off. First, engage the switch briefly to reactivate the display. Checking the torque clutch setting 1. Press the torque set button. • Control panel display Display: The torque set lights up.Battery indication lamp: The upper bar of the battery flashes on and off. Checking the interval 1. Press the interval set button. • Control panel display Display: The interval set lights up.Battery indication lamp: The middle bar of the battery flashes on and off. Checking tool circuits 1. Press the torque set button. • Control panel display Display: The torque set display lights up. Battery indication lamp: The middle and lower bars of the battery flash on and off. DisplayTool circuit H EYFLA1 H3 EYFLA H4EYFLA3 NOTE: • If you engage the switch while a setting is being displayed, the control panel will revert to the torque clutch setting dis-play. CAUTION: • The torque set display is not intended to be used to identify the type of drive component parts (hammer, etc.) used in a particular tool.
- 13 - Error Display In the event of a tool or battery pack malfunction, the control panel will display an error message. Please check the tool or battery pack as described in the following chart before having them serviced. DisplayLikely causeCorrective action Setting errorRe-initialize the tool using the remote control. (See page 1.) The battery pack is too hot.Stop work and allow the battery pack to cool before resuming use of the tool. The tool is too hot to operate.Stop work and allow the tool to cool before resuming use. The contacts that connect the battery pack and tool are dirty.Remove any dirt. The battery pack has not been properly inserted into the tool.Insert the battery pack firmly into the tool. The pins on either the tool or battery pack have worn down.Replace the battery pack. Motor failure, etc.Stop using the tool immediately. Sensor malfunction, failure, etc. Tool circuit malfunction, failure, etc. [Battery Pack] For Appropriate Use of Bat tery Pack Liion Battery Pack (EYFB30) • For optimum battery life, store the Li-ion bat-tery pack following use without charging it. • When charging the battery pack, confirm that the terminals on the battery charger are free of foreign substances such as dust and water etc. Clean the terminals before charging the battery pack if any foreign sub-stances are found on the terminals. The life of the battery pack terminals may be affected by foreign substances such as dust and water etc. during operation. • When battery pack is not in use, keep it away from other metal objects like: paper clips, coins, keys, nails, screws, or other small metal objects that can make a con-nection from one terminal to another. Shorting the battery terminals together may cause sparks, burns or a fire. • When operating the battery pack, make sure the work place is well ventilated. • When the battery pack is removed from the main body of the tool, replace the battery pack cover immediately in order to prevent dust or dirt from contaminating the battery terminals and causing a short circuit.
- 14 - Battery Pack Life The rechargeable batteries have a limited life. If the operation time becomes extremely short after recharging, replace the battery pack with a new one. Battery Recycling ATTENTION: FOR Liion Battery Pack, EYFB30A Li-ion battery that is recyclable powers the product you have purchased.Please call 18008BATTERY for infor-mation on how to recycle this battery. [Battery Charger] Charging Read the operating manual for Panasonic bat-tery charger for the battery pack before charg-ing. Before charging the bat tery When charging EYFB30:Charge the battery at a temperature of 5°C (41°F) to 40°C (104°F). The battery pack cannot be charged at a tem-perature of less than 5°C (41°F). If the tem-perature of the battery pack is less than 5°C (41°F), fi rst remove the battery pack from the charger and allow it to sit for an hour in a location where the temperature is 5°C (41°F) or warmer. Then charge the battery pack again. VI. MAINTENANCE Use only a dry, soft cloth for wiping the unit. Do not use a damp cloth, thinner, benzine, or other volatile solvents for cleaning. VII. ACCESSORIES Charger • EY0L80 Battery pack • EYFB30 Remote control • EYFA30 Protector for tool • EYFA01-A (Blue) • EYFA01-Y (Yellow) • EYFA01-H (Gray) Protector for battery • EYFA0-H
- 15 - VIII. SPECIFICATIONS MAIN UNIT ModelEYFLA1 EYFLAEYFLA3 AAQJ Moter10.8 V DC Chuck sizeSingle-ended9 – 9.5 mm (3/64" – 3/8")9 – 9.5 mm (3/64" – 3/8") □9.5 mm(3/8")□ 1.7 mm (1/") Double-ended 1 mm (15/3") 1 mm (15/3") No load speedStage13 – 56789 – 30·F 0 – 9500 – 10000 – 10500 – 13000 – 14500 – 1550 0 – 300 134 – 30·F 0 – 13000 – 14500 – 1550 0 – 3000 – 300 Impact per minuteStage13 – 56789 – 30·F 0 – 19000 – 1950 0 – 100 0 – 500 0 – 800 0 – 30000 – 4000 134 – 30·F0 – 500 0 – 8000 – 30000 – 3600 0 – 3000 Maximum torque40 N·m (408 kgf-cm, 354 in-lbs)90 N·m (918 kgf-cm, 796 in-lbs) 10 N·m (14 kgf-cm, 106 in-lbs) Torque control function operating range Approx. 3 – N·m (31 – 4 kgf-cm, 7 – 195 in-lbs)Approx. 6 – 30 N·m (61 – 306 kgf-cm, 53 – 66 in-lbs)Approx. 16 – 53 N·m (163 – 540 kgf-cm, 14 – 469 in-lbs) Overall length 158 mm (6-7/3")164 mm (6-7/16") Weight (with battery pack: EYFB30)1.3 kg (.8 lbs)1.35 kg (.9 lbs)
- 16 - BATTERY PACK (not included with shipment) ModelEYFB30 Storage batteryLi-ion battery Battery voltage10.8 V DC (3.6 V/6 cells) Capacity3 Ah BATTERY CHARGER (not included with shipment) ModelEY0L80 RatingSee the rating plate on the bottom of the charger. Weight0.95 kg (.1 lbs) [Liion battery pack] Charging time3 Ah 10.8 V EYFB30Usable: 40 min. Full: 65 min. Remote control (not included with shipment) ModelEYFA30 Battery voltage3 V DC Dimensions 54 mm (-1/8") × 86 mm (3-3/8") × 10 mm (13/3”) Weight (with battery) Approximately 9 g (0.6 lbs)