Home > Panasonic > Camera > Panasonic Color Cctv Camera Wv Cw244f Operating Instructions

Panasonic Color Cctv Camera Wv Cw244f Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Color Cctv Camera Wv Cw244f Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							!6
    !2
    !4
    !5
    !3
    !2Dome cover
    !3Video output cable with BNC connectorConnects with the video connector of the
    monitor.
    !4Camera power cable
    Supplies 24 V AC or 12 V DC from an exter-
    nal power source. 
    !5Heater power cableSupplies 24 V AC from an external power
    source to an optional heater.
    !6Camera mounting bracketOnly WV-CW244S (surface mount type) is
    supplied with a mounting bracket for ceiling
    installation.
    ■Installation Plans & Preparations
    ●WV-CW244F
    “F” stands for flash mounting. This model can be mounted on a two-gang junction box (4“ x 4“) pre-
    installed in the wall or ceiling.
    1. Space
    Prepare a space larger than ø160 mm.
    2. Junction box
    Procure and install a junction box that meets the dimensions in the figure.
    3. Camera Fixing Screws
    Procure four screws (M4) suitable for the junction box.
    4. Cable route
    Cables will go behind the junction box.
    5. Waterproof Process
    When necessary, apply waterproof process to the camera and relevant portions.
    Be sure to apply silicone rubber to the camera fixing screws in case of outdoor installation.
    INSTALLATION
    Camera fixing screw x 4 (procured locally)
    46mm
    (1-13/16)
    83.5mm (3-5/16)
    ●WV-CW244S
    “S” stands for surface mounting. This model can be installed on the surface of the wall or ceiling
    using the supplied bracket.
    1. Space
    Prepare a space larger than ø160 mm.
    2. Bracket Fixing Screws
    To fix the bracket, procure four M4 screws suitable for the surface and structure of the wall/ceil-
    ing.
    3. Camera Fixing Screws
    Four screws are supplied as standard accessories.
    4. Cable route
    •When routing cables through the wall/ceiling, drill a hole as shown in the figure.
    •When routing cables sideway, open the sideway cable exit unscrewing the lid by use of a hexa-
    gon wrench. Screw the detached lid to the cable access hole on the bottom of the bracket.
    5. Waterproof Process
    When necessary, apply waterproof process to the camera and relevant portions.
    If you use camera fixing screws that are locally procured, be sure to apply silicone rubber to the
    screws.
    85 mm
    (3-3/8)
    85 mm
    (3-3/8)
    51 mm
    (2)
    Camera fixing screw x 4 (supplied) Bracket fixing screw x 4
    (procured locally)Bracket centerCable access hole
    for 3/4 pipe
    2nd transport 
    protection screw2. Remove the two red-colored screws provid-
    ed for transport protection using a Philips
    screwdriver.
    ■Mounting the Camera
    ●Disassembly of the camera
    1. Remove the dome cover by loosening three
    tamper-proof screws using the supplied bit.
    Color CCTV Camera
    Operating Instructions
    Model No.WV-CW244F
    WV-CW244S
    Before attempting to connect or operate this product,
    please read these instructions carefully and save this manual for future use.
    N0803-1093      3TR001693BAA      Printed in Japan
    PREFACE
    The WV-CW244 series is a 1/3” CCD color cam-
    era designed for use in a video surveillance
    system. The camera features a high picture
    The exclamation point within an
    equilateral triangle is intended to
    alert the user to the presence of
    important operating and mainte-
    nance (servicing) instructions in the
    literature accompanying the appli-
    ance.
    The lightning flash with arrowhead
    symbol, within an equilateral trian-
    gle, is interned to alert the user to
    the presence of uninsulated dan-
    gerous voltage within the products
    enclosure that may be of sufficient
    magnitude to constitute a risk of
    electric shock to persons.
    The serial number of this product may be found on
    the top of the unit.
    You should note the serial number of this unit in the
    space provided and retain this instruction as a per-
    manent record of your purchase to aid identification
    in the event of theft.
    Model No. 
    Serial No. 
    SA 1966
    SA 1965
    WARNING: To prevent fire or electric shock hazard, do not expose this appliance to rain or moisture. 
    The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such
    as vases, shall be placed on the apparatus.
    CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
    DO NOT REMOVE COVER (OR BACK).
    NO USER-SERVICEABLE PARTS INSIDE. REFER SER-
    VICING TO QUALIFIED SERVICE PERSONNEL.
    CAUTION
    RISK OF ELECTRIC
    SHOCK DO NOT OPEN
    NOTE: This equipment has been tested and found
    to comply with the limits for a Class A digital
    device, pursuant to Part 15 of the FCC Rules.
    These limits are designed to provide reasonable
    protection against harmful interference when the
    equipment is operated in a commercial environ-
    ment. This equipment generates, uses, and can
    radiate radio frequency energy and, if not installed
    and used in accordance with the instruction manu-
    al, may cause harmful interference to radio com-
    munications.
    Operation of this equipment in a residential area is
    likely to cause harmful interference in which case
    the user will be required to correct the interference
    at his own expense.
    FCC Caution: To assure continued compliance,
    (example - use only shielded interface cables when
    connecting to computer or peripheral devices). Any
    changes or modifications not expressly approved
    by the party responsible for compliance could void
    the userÕs authority to operate this equipment.For U.S.A
    quality thanks to the use of digital signal pro-
    cessing LSIs, and easy installation. 
    1.This product should be installed and con-
    nected by qualified service personnel or
    system installers in conformity with NEC.
    2.Use a class 2 power source supplying 12 V
    DC or 24 V AC.
    3.To prevent fire or electric shock hazard, use
    a UL listed cable (VW-1, style 1007) to con-
    nect the power supply to the camera.
    4.Be sure to use a ceiling board/wall having
    enough strength to support this camera. 
    5. Handle the camera with care.Do not abuse the camera. Avoid striking,
    shaking, etc. The camera could be dam-
    aged by improper handling or storage.
    6. Do not use strong or abrasive
    detergents.
    Use a dry cloth to clean the camera body
    when dirty.
    In case the dirt is hard to remove, use a
    mild detergent and wipe gently. Afterwards,
    wipe off the remaining detergent with a dry
    cloth.
    7. Clean the lens faceplate with care.
    Do not clean the lens with strong or abra-
    sive detergents. Use lens tissue or a cotton
    tipped applicator and ethanol.
    8. Never face the camera towards the sun.Do not aim the camera at bright objects.
    Whether the camera is in use or not, never
    aim it at the sun or other extremely bright
    objects. Otherwise, blooming or smear may
    be caused.
    9. Do not operate the camera beyond its
    specifications.
    Use the camera under conditions where
    temperature is between –10 °C to +50 °C
    (14 °F to 122 °F), and humidity is below
    90 %. The input power source is 24 V AC or
    12 V DC.
    10.Use a monitor whose resolution is at least
    equal to that of the camera.
    PRECAUTIONS
    •Mounting method: Flash mounting/WV-
    CW244F, Surface mounting/WV-CW244S
    •Signal processing: Automatic Light Control
    (ALC), Automatic Gain Control (AGC),
    Automatic Tracing White Balance (ATW),
    etc.
    •Synchronization: Internal, Line-Lock (only
    24 V AC), and Multiplexed Vertical Drive
    (VD2)•Minimum illumination: 2.4 lx (0.24 foot-can-
    dle) at WIDE
    •Signal-to-noise ratio: 50 dB (Equivalent to
    AGC OFF)
    •Horizontal resolution: 480 TV lines
    •Optional heater unit available for the cam-
    era used at temperatures between –10 ˚C
    and –30 ˚C (14˚F and –22˚F).
    FEATURES
    MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
    qFocus lock leverFixes the focus position after adjusting.
    wTilting lock screw
    Fixes the tilting position after adjusting.
    eZoom lock lever
    Fixes the zoom position after adjusting.
    rPanning tableAdjusts the panning angle of the camera.
    tAzimuth adjusterAdjusts the azimuth angle to obtain a level
    image.
    yPan lock screwFixes the panning position after adjusting.
    uHeater power connectorSupplies power to the optional heater unit
    when it is built in the camera. Connect here
    a harness sticking out from the heater unit.
    iSynchronization Mode SelectorSpecifies a source for synchronization.INT:Internal 2:1 interlace.LL:Line-lock mode driven by 24 V AC.
    The default setting is INT.
    Note:Do not set the switch to LL (Line-
    Lock) position when supplying 12 V DC
    to avoid synchronization error.
    oBack Light Compensation Selector
    ON:
    Compensates the background if it is
    brighter than the object.
    OFF:Does not compensate.
    The default setting is OFF.
    !0Aperture Level Selector
    SHARP:Sharpens the image outline.
    SOFT:Softens the image outline.
    The default setting is SHARP.
    !1Video jack (3.5-diam. mini jack)For connecting an LCD monitor to adjust
    the camera images. Use an L-type plug to
    save space.
    ON123OFF ON
    LL SYNC INT*
    OFF* BLC ON
    SOFT AP SHARP*
    2nd transport protection screw (Red)
    Space for heater unit
    qw
    e
    r
    t
    y u
    i
    o
    !0
    !1
    This Class A digital apparatus complies with cana-
    dian ICES-003.
    Cet appareil num
    						
    							SPECIFICATIONS
    Pick-up device: 768 (H) x 494 (V) pixels, Interline transfer CCD
    Scanning area: 4.8 (H) x 3.6 (V) mm (Equivalent to 1/3” pick-up tube)
    Scanning: 525 lines/60 fields/30 frames
    Horizontal: 15.734 kHz
    Vertical: 59.94 Hz
    Synchronization: Internal, Line-lock (only 24 V AC), or Multiplexed vertical drive
    (VD2)
    Video output: 1.0 V [P-P] NTSC composite 75 Ω/BNC connector
    Horizontal resolution: 480 lines
    Signal-to-noise ratio: 50 dB (Equivalent to AGC Off, weight On)
    Minimum illumination: 2.4 lx (0.24 footcandle) (WIDE),
    When the optional WV-CW2C dome cover is installed.
    1.0 lx (0.1 footcandle) (WIDE),
    Detail: SHARP or SOFT, selectable
    White balance: ATW
    Lens Mount: CS-mount
    Lens
    Focal length: 3.8 mm - 8 mm
    Maximum aperture ratio: 1:1.4 (Wide), 1:1.8 (Tele)
    Angular field of view: Horizontal: 35.6 ˚ - 73.6 ˚
    Vertical: 26.6 ˚ - 53.4 ˚
    Focusing range: 1.2 m - ∞(3.9 ft - ∞)
    Ambient operating temperature: –10 °C - +50 °C (14 °F - 122 °F)
    –30 °C - +50 °C (–22 °F - 122 °F) 
    (When the optional heater unit built in)
    Ambient operating humidity: Less than 90 %
    Power source and
    Power consumption: 12 V DC, 265 mA (Camera)
    24 V AC 60 Hz, 3.0 W (Camera)
    24 V AC 60 Hz, 12.1 W (Heater unit)
    Dimensions: WV-CW244F: 133 mm (H) x 152.5 mm (D)
    5-1/4” (H) x 6” (D)
    WV-CW244S: 136.5 mm (H) x 160 mm (D)
    5-3/8” (H) x 6-5/16” (D)
    Weights: WV-CW244F: 1.2 k
    g(2.7 lbs.)
    WV-CW244S: 1.7 kg(3.8 lbs.)
    Weights and dimensions indicated are approximate.
    Specifications are subject to change without notice.
    OPTIONAL ACCESSORIES
    STANDARD ACCESSORIES
    Operating Instructions (this document) ............................................. 1 pc.
    The following are for installation.
    Tamperproof screw bit  ...................................................................... 1 pc.
    Camera mounting bracket (supplied only to WV-CW244S) ............... 1 pc.
    Camera fixing screw (with a plastic washer) ..................................... 4 pcs.
    (supplied only to WV-CW244S)
    Heater unit  ......................................................................................... WV-CW3H
    Clear dome cover  .............................................................................. WV-CW2C
    Camera mounting bracket (for WV-CW244F) .................................... WV-Q112
    PANASONIC CANADA INC.5770 Ambler Drive, Mississauga, 
    Ontario, L4W 2T3 Canada (905)624-5010
    PANASONIC SALES COMPANY
    DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO INC.
    San Gabriel Industrial Park 65th Infantry Ave. KM. 9.5 Carolina, 
    P.R. 00985 (809)750-4300
    Panasonic Digital Communications & Security CompanyUnit of Matsushita Electric Corporation of AmericaSecurity Systems Groupwww.panasonic.com/cctvExecutive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094Zone Office
    Eastern:One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303Central:1707 N.Randal Road, Elgin, IL 60123 (847) 468-5205Western:6550 Katella Ave., Cypress, CA 90630 (714) 373-7840
    2003     © Matsushita Electric Industrial Co., Ltd.  All rights reserved.
    OPTIONAL HEATER UNIT
    ■Optional Heater Unit WV-CW3H
    ●Introduction
    Installing this heater unit enables the camera to operate under in a low-temperature environment of
    –30°C (–22°F). The heater turns on automatically when the temperature inside the camera drops
    below +10°C (50°F) and turns off when it rises.
    A small fan inside the unit will minimize condensation on the surface of the dome cover caused by
    changes in ambient temperature unless temperatures change too rapidly. The fan will stop when
    there is no possibility of condensation.
    ●Precautions
    •This product should be installed and connected by qualified service personnel or system
    installers.
    •Do not use the same 24 V AC power source supplying the power to the camera for the heater
    unit. Connect another 24 V AC power source to the heater unit. If the same power source is
    used, turning the heater on and off may disturb the camera images.
    •When servicing, pay attention to high temperature on the surface of the unit. Disconnect the har-
    ness and wait until it cools.
    •When you install the camera in a low-temperature location and start operating it, it may take time
    (around 30 minutes) for the inside of the
    camera to warm up. Cut  power once then
    supply power again.
    ●Installation
    1. Open the dome cover. (See Disassembling
    the camera.)
    2. Place the heater unit in the camera and fix
    it with the supplied screw.
    3. Insert the harness into the heater unit con-
    nector of the camera.
    4. Fold the desiccant pack in half, and attach
    it with adhesive tape to  point A shown in
    the figure.
    Note:Attach the desiccant pack so that it
    does not block ventilation holes or
    hang over the top of the wall.
    5. Attach the dome cover while paying atten-
    tion not to pinch the harness cable.
    6. Connect the heater power cable of the camera. (See Connection.)
    ●Specifications
    Required power: 24 V AC, 60 Hz
    Power consumption: 12.1 W maximum
    Dimensions: 29 mm (H) x 83 mm (W) x 89.5 mm (D) 
    [1-1/8” (H) x 3-1/4”(W) x 3-1/2”(D)]
    Weights: 45 
    g(0.1 lbs)
    ●Accessories
    Fixing screw (M3 x 12) ...................................1 pc.
    Desiccant pack  .............................................1.pc.
    Adhesive tape
    Point “A”
    (inside the wall)Supplied screw
    Harness
    Fold
    Adhesive tape
    Point “A”
    (inside the wall)Supplied screw
    Harness
    Fold
    Azimuth adjuster
    ●Heater unit installation
    See OPTIONAL HEATER UNIT for details.
    ■Connections
    ●Video Output Connection
    Connect the video output connector to the mon-
    itor or other system device with the procured
    coaxial cable. The maximum extensible length
    is shown in the table.
    ●Power Connection
    ●Wire Colors & Functions
    Camera power cable
    Heater power cable
    Type of RG-59/U RG-6/U RG-11/U RG-15/Ucoaxial cable (3C-2V) (5C-2V) (7C-2V) (10C-2V)
    Recommended (m) 250 500 600 800
    maximum
    cable length (ft) 825 1 650 1 980 2 640
    Wire Color 24 V AC 12 V DC
    Black 24 V AC (L) Positive
    White 24 V AC (N) Negative
    Green/Yellow Ground Not Used
    ●Cable Length and Wire Gauge
    24 V ACThe recommended cable length and thick-
    ness are shown in the table for reference.
    The voltage supplied to the power terminals
    of the camera should be within 19.5 V AC
    and 28 V AC.
    12 V DCUse the formula below to calculate the
    power cable and power supply. The voltage
    supplied to the power terminals of the cam-
    era should be within 10.5 V DC and 16 V
    DC.
    10.5 V DC ≤VA−2(R x I x L) ≤16 V DC
    L  : Cable length (m) (ft)
    R  : Resistance of copper wire (
    Ω/m) (Ω/ft)
    VA: DC output voltage of power supply unitI   : DC current consumption (A). See spec-
    ifications.
    Copper wire
    size (AWG)
    Length of
    Cable
    (Approx.)#24
    (0.22 mm2)
    95
    314#22
    (0.33 mm2)
    150
    495#20
    (0.52 mm2)
    255
    842#18
    (0.83 mm2)
    425
    1 403
    Recommended wire gauge for 24 V AC line.
    Copper wire
    size (AWG)
    Resistance
    Ω/m
    Resistance
    Ω/ft#24
    (0.22 mm
    2)
    0.078
    0.026#22
    (0.33 mm2)
    0.050
    0.017#20
    (0.52 mm2)
    0.03
    0.010#18
    (0.83 mm2)
    0.018
    0.006
    Resistance of copper wire [at 20 °C (68 °F)]
    (m)
    (ft)
    Wire Color 24 V AC
    Red 24 V AC (L)
    White 24 V AC (N)
    Caution:•Be sure to connect the GND (grounding)
    lead of the camera and grounding terminal
    of the power supply when using a 24 V AC
    power source.
    Adhesive tape
    Point “A”
    (inside the wall)Supplied screw
    Harness
    Fold
    ■Image Adjustment
    You can manually adjust the pan/tilt/azimuth
    angles, focus, and zoom while observing the
    connected monitor. 
    3. Zoom
    •Unlock the zoom lever.
    •Move the lever to adjust the zoom.
    •Lock the lever.
    4. Focus
    •Unlock the focus lever.
    •Move the lever to adjust the focus.
    •Lock the lever.
    5. Reinstalling the dome cover
    •Attach the dome cover to the camera.
    •Tighten the three tamper-proof screws.
    ●Waterproof Process
    When necessary, apply waterproof process to protect the camera from water soak.
    1. Power cord
    First, tape the individual wires, finally all of them as a whole.
    2. Connector junctions
    Tape the BNC-BNC junction point.
    3. Gaps and holes
    Apply such a waterproof material as silicone clay (rubber) to the gaps, screws, holes, and other
    relevant portions.
    4. Camera Fixing Screws
    WV-CW244FBe sure to apply silicone rubber to the camera fixing screws in case of outdoor installation.WV-CW244S
    If you use camera fixing screws that are locally procured, be sure to apply silicone rubber to
    the screws.
    Tilting lock screw 
    (stainless)
    Pan lock screw (stainless)
    Panning table Variable angles 
    plus or minus 75 ° 
    (max.)
    Zoom lock lever
    Focus lock lever
    FA R
    NEARTELE
    WIDE
    Power cord
    Video output cable
    ●Mounting the camera
    1. Fix the camera to the installation surface. 
    WV-CW244F•Fix the camera on the junction box using four screws (locally procured).WV-CW244S
    •Fix the supplied bracket on the wall/ceiling using four screws (locally procured).
    •Fix the camera on the bracket using four screws (supplied).
    2. Perform connections referring to 
    ■Connections.
    3. Reinstall the camera to the bracket or junction box referring to step 1 above.
    4. Adjust the image referring to 
    ■Image Adjustment. 
    5. Apply waterproof means referring to 
    ●Waterproof Process.
    Notes:•Do not hold the camera by lens unit to
    adjust panning, tilting, or azimuth.
    •The video output to the BNC will be inter-
    rupted while an LCD monitor is connected
    to the video jack.
    1. Connect an LCD monitor to the video jack.
    2. Pan/tilt/azimuth adjustment
    •Loosen the two screws locking the pan and
    tilt tables.
    •Pan and tilt the table to aim the camera at
    what you need to watch.
    •Turn the azimuth adjuster to obtain a level
    image.
    •Tighten the two screws after adjusting.
    Adhesive tape
    Point “A”
    (inside the wall)Supplied screw
    Harness
    Fold 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Color Cctv Camera Wv Cw244f Operating Instructions