Page 71
Ð 72 Ð Error messages When a warning occurs in this unit, the warning lamp lights up. Opening the DIAG menu will display the warning description on the counter display and the monitor. Also, when an abnormal operation is detected in this unit, the AUTO OFF lamp lights up and a message appears on the counter display. DIAG menu This display the VCR information. VCR information includes ÒWARNINGÓ information and ÒHOURS METERÓ (usage time) information. A DIAG menu appears on the monitor when the monitor is...
Page 72
Ð 73 Ð Displaying the ÒHOURS METERÓ information Turn the search dial to move the cursor ( * ). The description for the item where the cursor is located is shown on the counter display. Item No. Item Description H00 OPERATION H01 DRUM RUN H02 TAPE RUN H03 THREADING H11 DRUM RUN r H12 TAPE RUN r H13 THREADING r H30 POWER ON ¥The resettable items in the ÒHOURS METERÓ information are reset by the shop when performing maintenance or other work. ¥The search buttons and the search dial cannot be operated while...
Page 73
Ð 74 Ð Table of AUTO OFF Error messages Monitor display DescriptionVTR operation(Restart condition) CAP ROTATE TOO SLOW CAP TENSION ERROR DEW DRUM ROTATE TOO FAST E-FF DRUM ROTATE TOO SLOW If the capstan motor speed is abnormally low, the AUTO OFF lamp lights, and the message display flashes.STOP (POWER OFF®ON) If an abnormal tension at the supply side is detected in the capstan mode, the AUTO OFF lamp lights, and the message display flashes.STOP (POWER OFF®ON) If condensation is detected, the AUTO...
Page 74
Ð 75 Ð SERVO CONTROL ERROR Counter display DescriptionVTR operation(Restart condition) REEL DIR UNMATCHIf the reel motor at the take-up side is running in the reverse direction, the AUTO OFF lamp lights, and the message display flashes.STOP (POWER OFF®ON) REEL TENSION ERROR SERVO COMM ERROR SERVO ERROR S-FF/REW TIMEOVER S REEL ROTA TOO FAST T REEL ROTA TOO FAST T REEL TORQUE ERROR UNLOAD ERROR S REEL TORQUE ERROR WINDUP ERROR If an abnormal tension at the supply side is detected in the reel mode, the...
Page 75
Ð 76 Ð RS-232C interface 1. Introduction (1) The VTR can be operated by commands when the RS-232C interface is used. (See command table on page 79 Ð 81.) (2) Conditions for acknowledging commands from RS-232C interface The front panel REMOTE/LOCAL switch must be at REMOTE. The setup menu item No. 204 ÒRS232C SELÓ must be ON. If the above conditions are not met, [ACK] + [STX]ER001[EXT] is returned to the external unit. Whether the [ACK] code is returned depends on the setting which has been selected for...
Page 76
Ð 77 Ð 3. Software specifications Protocol 1) Communication parameters Communication system Asynchronous, full duplex Communication speed 300/600/1200/2400/4800/9600 Bit length 7 bit/8 bit Stop bit1 bit/2 bit Parity bitNONE/ODD/EVEN ACK code ACK code returned/ACK code not returned The ACK code is what is returned from the VTR to the controller when data has been successfully sent from the controller. The underlining indicates the factory settings. Any changes to the settings can be made using the setup...
Page 77
Ð 78 Ð RS-232C interface 3) Return format [VTR ® controller (PC)] The following responses are made to the command. If necessary, more than one response is made. n When the communication has terminated normally 1. The receive completion message is returned. [ACK] 06h 2. The execution completion message is returned. [STX] [command] [data] [ETX] 02h XX XX XX XX-XX 03h ¥[command]: This is the message (data) which is returned or the execution completion message identifier. ¥[data]: This is the...
Page 78
Ð 79 Ð 5. Command table (1) Commands relating to operation control ¥As for the return (completion) message, [ACK] is first returned when data is received, and the execution message is subsequently returned. It is only the execution message which is listed in this table. ¥In the case of commands not listed in the table, ER001 (invalid command) is returned after [ACK] has been returned. VTR operationSend commandReturn (completion) messageSupplementary notes [STX] OSP [ETX] STOP [STX] OSP [ETX]This command...
Page 79
Ð 80 Ð VTR operationSend commandReturn (completion) messageSupplementary notes [STX] OBF [ETX] STANDBY OFF[STX] OBF [ETX]This command is setting the VTR to standby OFF. [STX] OSR:data [ETX] SHTL REVERSE[STX] OSR [ETX]This is the reverse direction shuttle command. data = n: 0: 1: 2: 3: 4: 5: 6: 7: 8: 9: A:speed data STILL ´0.03 ´0.1 ´0.2 ´0.5 ´1 ´1.85 ´4.1 ´9.5 ´16 ´32: This speed differs according to the setting selected for setup menu No. 101 (SHTL MAX). : This speed differs according to the...
Page 80
Ð 81 Ð (2) Commands relating to inquiries ¥As for the return (completion) message, [ACK] is first returned when data is received, and the execution message is subsequently returned. It is only the execution message which is listed in this table. ¥In the case of commands not listed in the table, ER001 (invalid command) is returned after [ACK] has been returned. VTR operationSend commandReturn (completion) messageSupplementary notes [STX] QCD [ETX] CTL/TC DATA REQUEST [STX] CD data [ETX]This command is...