– 121 – MAIN Menu Screen 2 of 4 (SUB menus) VF DISPLAY screen What information is to be displayed inside the viewfinder is set on this screen. Item DISP CONDITION DISP MODE SAFETY ZONE CENTER MARK VF OUT VF DTL Variable range NORMAL SPECIAL 1-3 OFF-3-9 ON OFF Y NAM R G B 0 . . . 2 . . . 4 Remarks NORMAL:The statuses are displayed at all times. SPECIAL:The statuses are displayed only when the MODE CHECK switch is at ON. This selects ON or OFF for the safety zone selection display. 1:80%, 90% corner...
Page 122
– 122 – MAIN Menu Screen 2 of 4 (SUB menus) Remarks This sets the ZEBRA1 detection level (IRE value). This sets the ZEBRA2 detection level (IRE value). This selects ON or OFF for ZEBRA2 and for setting SPOT. FThe ZEBRA2 DETECT level should be set higher than the ZEBRA1 detect level when the SPOT setting is to be used. If it is set lower, ZEBRA will not be displayed. This selects the setting at which LOW LIGHT is to be displayed when the quantity of light entering the camera is too low. VF display USER...
Page 123
– 123 – Item EXTENDER SHUTTER TAPE BATTERY FILTER WHITE GAIN LEVEL METER IRIS CAMERA ID Variable range ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF CH1 CH1Q CH2 OFF IRIS SoIRIS S OFF ON OFF Remarks This selects ON or OFF for the extender display. This selects ON or OFF for the shutter speed display. This selects ON or OFF for the remaining tape length display. This selects ON or OFF for the battery voltage display. This selects ON or OFF for the filter No. display. This selects ON or OFF for the AWB...
Page 124
– 124 – MAIN Menu Screen 2 of 4 (SUB menus) CAMERA ID screen The camera ID settings are performed on this screen. Each time the UP button is pressed, the character display changes in the following order: space (Å)>english letters (A to Z)>numbers (0 to 9)>symbols (space, >,
Page 125
– 125 – Item GAIN (0 dB) GAIN (p3 dB) SHUTTER WHITE PRESET EXTENDER FILTER SUPER V Variable range ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Remarks This selects whether the LED is to light up when the gain has a value other than 0 dB. This selects whether the LED is to light up when the gain has a value other than p32 dB. This selects whether the LED is to light up when the shutter is ON. This selects whether the LED is to light up when the AWB CH is PRESET. This selects whether the LED is to...
Page 126
– 126 – Item SUPER V FILTER INH SHOCKLESS AWB COLOR BAR S.GAIN OFF S.IRIS/ S.BLK SW S.BLK LVL ECU DATA SAVE Variable range FRM1 FRM2 ON OFF OFF NORMAL SLOW FAST SMPTE SNG S.GAIN L/M/H S.IRIS S.BLK INH p10 p20 p30 ON OFF Remarks This selects ON or OFF for SUPER V. FRM1:Normal mode FRM2:Residual image reduction mode This switches whether the AWB memory (A and B channels) data is to be stored for each filter. ON:The data is stored in the A and B channel memories (2 memory units) only regardless of the...
Page 127
– 127 – Item 30 dB 36 dB Variable range ON OFF ON OFF Remarks This selects the gain when the SUPER GAIN switch is pressed. This selects the gain when the SUPER GAIN switch is pressed. VF display ENG ENG MAIN Menu Screen 2 of 4 (SUB menus) SUPER GAIN screen The super gain values to be allocated to the SUPER GAIN switch are set on this screen. |Note{ ÁEach time the SUPER GAIN switch is pressed when all the super gain values have been allocated, the gain is switched by one level in the following sequence:...
Page 128
– 128 – Item HUMID OPE 26P CONTROL REC START TC MODE UB MODE PAUSE TIMER BATTERY SEL Variable range ON OFF OFF BOTH ON ALL NORMAL DF NDF USER DATE TIME EXT GPSF 10 20 30 60 NiCd12 NiCd13 NiCd14 IDXL-40 L-60 L-90 ANTON- D IDX-D Remarks This selects the VTR operation when condensation has formed. ON:Operation continues as usual. OFF:All operations are disabled except for the POWER switch and EJECT button. This selects 26P remote control. OFF:Unit only (no 26P control). BOTH:Unit and 26P remote control...
Page 129
– 129 – Item TCG VF DISP TCG SET HOLD FIRST REC TC Variable range ON OFF ON OFF REGEN PRESET VF display ENG ENG ENG Remarks This selects ON or OFF for time code display in the viewfinder. ON:The time code is displayed. OFF:The time code is not displayed. This selects the TCG operation when operation is performed in the following sequence: TCG SET>power OFF>power ON>REC. ON:The fact that TCG SET has been selected is stored in the memory when the power is switched off, and regeneration is not performed....
Page 130
– 130 – Item BATT NEAR END BATT END TAPE NEAR END TAPE END Variable range ON OFF ON OFF ON OFF ON OFF Remarks This selects ON or OFF for the warning beeps heard when the battery charge is nearly depleted. This selects ON or OFF for the warning beeps heard when the battery charge is depleted. This selects ON or OFF for the warning beeps heard when the tape nears the end. (A warning is given about 3 minutes before the tape reaches its end.) This selects ON or OFF for the warning beeps heard when the tape...