61 RS-232C $Query control commands Sends data of computer Return data from VTRDescription of command [STX] QOS [ETX] [STX] OPSdata [ETX] data = AD0AD1AD2AD3AD4 Refer to the bitmap table (B) for details of AD .Queries the operation modes. The current VTR mode is detected and sent by the bitmap information. The bitmap information is converted into ASCII code and returned by the VTR. [STX] QRA [ETX] [STX] RAm [ETX] m = N: ACK ON F: ACK OFFQueries the ACK (Acknowledge) code response setting. [STX] QRS [ETX] [STX] RSEm [ETX] m = 0: Normal 1: No completion command 2: No completion command/No errorQueries the search end mode setting. [STX] QRV:m [ETX] Parameters m = A: AV system control ROM version S: Sub-code microcomputer version C: Cylinder servo ROM version R: Reel servo ROM version I: Interface ROM version No parameter: Interface ROM version[STX] VERdata [ETX] data = d1d2.d3d4-d5d6-d7.d8d9 d1 d9: Software program versionQueries the software program version used for each microcomputer. [STX] QSM [ETX] [STX] SMMm [ETX] m = S: MEMORY STOP O: REPEAT ONE TIME A: CONTINUE F: OFFQueries the memory mode. [STX] QSY [ETX] [STX] SMILPdata [ETX] data = wwghmmssff ww = LP: CTL data reference SP: TC data reference g = Blank: With a positive value – sign: With a negative value h = 0 9: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: FramesQueries the counter value stored in the memory.
62 RS-232C OBitmap table (B) ADDRESS BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0 AD 0FULL EE SELECT EE 0 0 0 0TAPE END ()TAPE TOP () AD 1SHORT PLAY 0 STANDBY 0 0 0 0 SERVO LOCK AD 2REC INHIBIT TABCASSETTE IN/OUT0 VTR STATUS AD 3TAPE DIRECTIONSHUTTLE SPEED AD 40INSERT VIDEOINSERT AUDIO CH1INSERT AUDIO CH20000 VTR STATUS DATA BIT4BIT0VTR STATUS 1, 1, 1, 1, 1INSERT PAUSEBIT4 BIT0VTR STATUS 0, 1, 0, 0, 1PLAY PAUSE 0, 1, 0, 0, 0PLAY 0, 0, 0, 1, 1FAST FORWARD 0, 0, 0, 1, 0REWIND 0, 0, 0, 0, 1EJECT 0, 0, 0, 0, 0STOP 1, 1, 1, 1, 0INSERT 0, 1, 1, 1, 0SEARCH 0, 1, 1, 0, 1AUDIO INSERT PAUSE 0, 1, 1, 0, 0AUDIO INSERT 0, 1, 0, 1, 1RECORDING PAUSE 0, 1, 0, 1, 0RECORDING SHUTTLE SPEED DATA BIT4BIT0SHUTTLE SPEED 60(±) 9.5a or moreBIT4 BIT0SHUTTLE SPEED 2A(±) 0.2a or more but less than (±) 0.43a 20(±) 0.1a or more but less than (±) 0.2a 13(±) 0.03a or more but less than (±) 0.1a 00STILL 59(±) 3.0a or more but less than (±) 9.5a 4A(±) 1.85a or more but less than (±) 3.0a 40(±) 1.0a or more but less than (±) 1.85a 36(±) 0.43a or more but less than (±) 1.0a “1” is used as the TAPE END bit and TAPE TOP bit when the tape start or end is detected, and the bits are cleared to “0” when queried by the QOS command.
63 RS-232C $Query control commands Sends data of computer Return data from VTRDescription of command [STX] QSP:m [ETX] Parameters m = B: BEGIN point E: END point[STX] SMPdata [ETX] data = pw:ghmmssff OWhen CTL data is to be used as the reference pw = BP: BEGIN point EP: END point g = Blank: With a positive value – sign: With a negative value h = 0 9: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames OWhen TC data is to be used as the reference pw = BP: BEGIN point EP: END point gh = 00 23: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: FramesQueries the repeat position which has been stored in the memory. Error code ER001 is returned from the VTR when the data has not been entered. [STX] QTT [ETX] [STX] TSTdata [ETX] data = mmmm mmmm = 0000: 0.5 sec. 0005: 5 sec. 0010: 10 sec. 0030: 30 sec. 0100: 1 min. 0200: 2 min.Queries the standby OFF timer which has been stored in the memory. [STX] QVI [ETX] [STX] VIm [ETX] m = L: LINE S: S-VIDEO D: OPTIONQueries the position of the INPUT SELECT switch. [STX] QVM [ETX] [STX] VMDm [ETX] m = A: Color B: MonochromeQueries the color mode.
64 RS-232C $Communication control commands Sends data of computer Return data from VTRDescription of command [STX] RAN [ETX] [STX] RAN [ETX] Enables the return of the ACK (Acknowledge) code. This command is ignored while a search control command is being processed. [STX] RAF [ETX] [STX] RAF [ETX] Disables the return of the ACK (Acknowledge) code. This command is ignored while a search control command is being processed. [STX] RCK [ETX] [STX] RCK [ETX] Checks whether communication is established. This command is ignored while a search control command is being processed. [STX] RSE:m [ETX] Parameters m = 0: Normal 1: No completion command 2: No completion command/No error[STX] RSE [ETX] Sets the send timing and enable or disable for sending the search completion command. OParameter setting: normal When search is commenced: ACK code is returned. When search is completed: [STX] ((([ETX] is returned. When search is aborted: [STX] ER ((([ETX] is returned. OParameter setting: no completion command When search is commenced: ACK code is returned, and then [STX] ((([ETX] is returned. When search is completed: No return. When search is aborted: [STX] ER ((([ETX] is returned. OParameter setting: no completion command/no error When search is commenced: ACK code is returned, and then [STX] ((([ETX] is returned. When search is completed: No return. When search is aborted: No return. This command is ignored while a search control command is being processed.
65 RS-232C $Search control commands Sends data of computer Return data from VTRDescription of command [STX] SCP:data [ETX] Parameters data = ghmmssff OWhen CTL data is to be used as the reference g = Blank: With a positive value – sign: With a negative value h = 0 9: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames OWhen TC data is to be used as the reference gh = 00 23: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames[STX] SCP [ETX] Searches the counter value which was designated by the parameter. Playback is commenced upon completion of the search. If the designated position is an illegal position (the target position does not exist), error code ER122 will be returned from the VTR, which is then set to the STOP mode. When the OSP (STOP) command or OEJ (tape EJECT) command is issued during operation, error code ER123 is returned from the VTR. If the VTR’s operation mode has been changed by operating the controls on its front panel, error code ER121 will be returned from the VTR. If the tape end position is reached during operation, error code ER120 will be returned from the VTR. When data differing from the data used as the reference has been sent, error code ER001 will be returned from the VTR. This command is ignored while a search control command is being processed and in any of the following modes. EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE [STX] SCS:data [ETX] Parameters data = ghmmssff OWhen CTL data is to be used as the reference g = Blank: With a positive value – sign: With a negative value h = 0 9: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames OWhen TC data is to be used as the reference gh = 00 23: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames[STX] SCS [ETX] Searches the counter value which was designated by the parameter. The STILL mode is established upon completion of the search. If the designated position is an illegal position (the target position does not exist), error code ER122 will be returned from the VTR which is then set to the STOP mode. When the OSP (STOP) command or OEJ (tape EJECT) command is issued during operation, error code ER123 is returned from the VTR. If the VTR’s operation mode has been changed by operating the controls on its front panel, error code ER121 will be returned from the VTR. If the tape end position is reached during operation, error code ER120 will be returned from the VTR. When data differing from the data used as the reference has been sent, error code ER001 will be returned from the VTR. This command is ignored while a search control command is being processed and in any of the following modes. EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE
66 RS-232C $Search control commands Sends data of computer Return data from VTRDescription of command [STX] SMI:data [ETX] Parameters data = wwghmmssff OWhen the counter value is to be stored in the memory ww = LC: CTL data reference SC: TC data reference “ghmmssff” is omitted. OWhen the parameter value for which the CTL data serves as the reference is to be stored in the memory ww = LP: CTL data reference g = Blank: With a positive value – sign: With a negative value h = 0 9: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames OWhen the parameter value for which the TC data serves as the reference is to be stored in the memory ww = SP: TC data reference gh = 00 23: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames[STX] SMI [ETX] Stores the counter value and parameter value in the memory at the time when this command is received. This command is ignored while a search control command is being processed. [STX] SMM:m [ETX] Parameters m = S: MEMORY STOP O: REPEAT ONE TIME A: CONTINUE F: OFF[STX] SMM [ETX] Sets the memory mode. This command is ignored while a search control command is being processed.
67 RS-232C $Search control commands Sends data of computer Return data from VTRDescription of command [STX] SMP:data [ETX] Parameters data = pww:ghmmssff OWhen the counter value is to be stored in the memory p = B: BEGIN point E: END point ww = LC: CTL data reference SC: TC data reference “ghmmssff” is omitted. OWhen the parameter value for which the CTL data serves as the reference is to be stored in the memory p = B: BEGIN point E: END point ww = LP: CTL data reference g = Blank: With a positive value – sign: With a negative value h = 0 9: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames OWhen the parameter value for which the TC data serves as the reference is to be stored in the memory p = B: BEGIN point E: END point ww = SP: TC data reference gh = 00 23: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames OWhen the designated position is not to be entered data = BN: No entry of BEGIN point EN: No entry of END point[STX] SMP [ETX] Sets the repeat position. When the BEGIN point and END point have been designated in different modes, they are converted inside the VTR and set in the mode which was last designated. Parameter “ff” is processed as “00” inside the VTR. This command is ignored while a search control command is being processed.
68 RS-232C $Search control commands Sends data of computer Return data from VTRDescription of command [STX] SMS [ETX] [STX] SMS [ETX] Searches the counter value at the time when the command stored in the memory was received. The STILL mode is established upon completion of the search. If the designated position is an illegal position (the target position does not exist), error code ER122 will be returned from the VTR which is then set to the STOP mode. When the OSP (STOP) command or OEJ (tape EJECT) command is issued during operation, error code ER123 is returned from the VTR. If the VTR’s operation mode has been changed by operating the controls on its front panel, error code ER121 will be returned from the VTR. If the tape end position is reached during operation, error code ER120 will be returned from the VTR. When data differing from the data used as the reference has been sent or when the counter value has not been stored in the memory, error code ER001 will be returned from the VTR. This command is ignored while a search control command is being processed and in any of the following modes. EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE [STX] SPT:data [ETX] Parameters data = ghmmssff OWhen CTL data is to be used as the reference g = Blank: With a positive value – sign: With a negative value h = 0 9: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames OWhen TC data is to be used as the reference gh = 00 23: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames[STX] SPT [ETX] Plays the tape to the position which was designated by the parameter. The VTR is set to the STILL mode upon completion of playback. If the designated position is before the current position, the tape is not played back, and the VTR is set to the STILL mode. When the OSP (STOP) command or OEJ (tape EJECT) command is issued during operation, error code ER123 is returned from the VTR. If the VTR’s operation mode has been changed by operating the controls on its front panel, error code ER121 will be returned from the VTR. If the tape end position is reached during operation, error code ER120 will be returned from the VTR. This command is ignored while a search control command is being processed and in any of the following modes. EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE
69 RS-232C $Search control commands Sends data of computer Return data from VTRDescription of command [STX] SRS:data [ETX] Parameters data = wghmmssff OWhen CTL data is to be used as the reference w = L: CTL data reference g = Blank: With a positive value – sign: With a negative value h = 0 9: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames OWhen TC data is to be used as the reference w = S: TC data reference gh = 00 23: Hours mm = 0059: Minutes ss = 0059: Seconds ff = 0029: Frames[STX] SRS [ETX] Searches the counter value which was designated by the parameter. The STILL mode is established upon completion of the search. If the designated position is an illegal position (the target position does not exist), error code ER122 will be returned from the VTR, which is then set to the STOP mode. When the OSP (STOP) command or OEJ (tape EJECT) command is issued during operation, error code ER123 is returned from the VTR. If the VTR’s operation mode has been changed by operating the controls on its front panel, error code ER121 will be returned from the VTR. If the tape end position is reached during operation, error code ER120 will be returned from the VTR. When data differing from the data used as the reference has been sent, error code ER001 will be returned from the VTR. This command is ignored while a search control command is being processed and in any of the following modes. EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE [STX] SUB:data [ETX] Parameters data = uuuuuuuu:d u = 0 F: User’s bit value (“” is designated for a user’s bit value which is not going to be searched) d = F: Forward direction R: Reverse direction[STX] SUB [ETX] Searches the start position of the user’s bit which was designated by the parameter. The STILL mode is established upon completion of the search. The search is enabled when the same user’s bit value continues for at least 5 seconds. When the OSP (STOP) command or OEJ (tape EJECT) command is issued during operation, error code ER123 is returned from the VTR. If the VTR’s operation mode has been changed by operating the controls on its front panel, error code ER121 will be returned from the VTR. If the tape end position is reached during operation, error code ER120 will be returned from the VTR. This command is ignored while a search control command is being processed and in any of the following modes. EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE
70 RS-232C $Timer control commands Sends data of computer Return data from VTRDescription of command [STX] TST:data [ETX] Parameters data = mmmm mmmm = 0000: 0.5 sec. 0005: 5 sec. 0010: 10 sec. 0030: 30 sec. 0100: 1 min. 0200: 2 min.[STX] TST [ETX] Sets the standby OFF timer. This command is ignored while a search control command is being processed.