Page 1
Français English F569576 Model No. Indoor Unit Outdoor Unit CS-XE9PKUA CS-XE12PKUACU-XE9PKUA CU-XE12PKUA Operating Instructions Air Conditioner RFP Operating Instructions Air Conditioner2-14 Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Instructions d’utilisation Climatiseur15-27 Merci d’avoir acheté un climatiseur Panasonic. Instructions d’installation...
Page 2
2 Provide maximum comfort, clean air and optimize energy saving ECONAVI and AUTO COMFORTEquipped with the human activity sensor, the air conditioner ensures to deliver cool or warm air to you, and keeps the room consistently comfortable with minimum energy consumption. See “To learn more...” for details. ROOM FREEZE PROTECTION FUNCTION (RFP)Used in spaces that are unoccupied during the winter, for the purpose of protecting any equipment or appliances which may be destroyed as a result of freezing...
Page 3
3 English Quick guide 123 Inserting the batteries 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries (can be used ~ 1 year) 3 Close the cover TIMER SET CANCEL ON OFF1 23 SETAC RC TIMER CANCEL ON OFF 13 SETCHECKRESETACRC 23 1 Clock setting 1 Press CLOCK 2 Set the time 3 Confi rm AUTO COMFORT MODE POWERFUL/ QUIET TEMP OFF/ON TIMER SET CANCEL ON OFF1 23 AIR SWING FAN SPEED RFP SETAC RC FAN SPEED AIR SWINGRFP AUTO HEAT COOL DRY FAN ECONAVIAUTOCOMFORT POWERFUL/QUIET...
Page 4
4 Safety precautions To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below: WARNINGThis sign warns of death or serious injury. CAUTIONThis sign warns of injury or damage to property. The instructions to be followed are classifi ed by the following symbols: This symbol denotes an action that is PROHIBITED. These...
Page 5
5 English To prevent overheating, fi re or electric shock:• Do not share the same power outlet with other equipment. • Do not operate with wet hands. • Do not over bend the power supply cord. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualifi ed persons in order to avoid a hazard. It is strongly recommended to install this unit using an Earth Leakage Circuit Breaker (ELCB) or Ground Fault Interrupt (GFCI) or Appliance Leakage Current Interrupt...
Page 6
RFP 6 IndicatorECONAVITo optimize energy saving MODETo select operation mode AUTO - For your convenience HEAT - To enjoy warm air COOL - To enjoy cool air DRY - To dehumidify the environment FAN - To circulate air in the room RFPTo select Room Freeze Protection • When selected, the unit will circulate the air in High mode for monitoring the temperature. When the sensor detects the temperature drops below 46°F / 8°C the compressor/heat pump operation begins, when the temperature reaches 50°F...
Page 7
7 English Note ECONAVI , POWERFUL/ QUIET , AUTO COMFORT • Can be activated in all modes and can be cancelled by pressing the respective button again. • Cannot be selected at the same time. To set the timer 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times. TIMERSET CANCEL ON OFF1 23 AC CCANCEL 3 ACC 213 1Select ON or OFF timerExample: OFF at 10:00 PM • Each time pressed: OFFCancel 2Set the time2 3Confi rmSET TIMER • To cancel ON or OFF timer, press ON...
Page 8
8 To learn more... Operation mode AUTO : During operation mode selection the POWER indicator blinks. • Unit selects operation mode every 10 minutes according to setting temperature and room temperature. HEAT : Unit takes a while to warm up. The POWER indicator blinks during this operation. COOL : Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode. DRY : Unit operates at low fan speed to give a gentle cooling operation. FA N : To circulate air in the room....
Page 9
9 English Operation conditions Use this air conditioner under the following temperature range. DBT : Dry bulb temperature WBT : Wet bulb temperature Temperature (°F/°C)Indoor Outdoor DBT WBT DBT WBT COOLMax. 89.6/32 73.4/23 114.8/46 78.8/26 Min. 60.8/16 51.8/11 0.0/-18 -/- HEATMax. 86.0/30 -/- 75.2/24 64.4/18 Min. 60.8/16 -/- 0.0/-18 -2.2/-19 Room Freeze Protection Function (RFP) Room Freeze Protection function (RFP) is used in spaces that are unoccupied during the winter, for the purpose of protecting...
Page 10
10 Cleaning instructions To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. A dirty unit may cause malfunction and you may see error code “H99”. Please consult authorized dealer. • Switch off the power at the circuit breaker before cleaning. • Do not touch the aluminium fi n, sharp parts may cause injury. • Do not use benzene, thinner or scouring powder. • Use only soap ( pH 7) or neutral household detergent. • Do not use water hotter than 104°F /...