Have a look at the manual Panasonic Air Conditioner S 26pk2u6_operation_cv6233320526 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CV6233320526 85464609338010 Operating Instructions Air Conditioner Model No. This air conditioner uses the refrigerant R410A. Before operating the unit, read these operating instructions thoroughly \ and keep them for future reference. Indoor Units 26 Nominal Capacity K2 Type K2 Wall Mounted 26 U-26PE1U6 Remarks Cooling/HeatingIndoor Unit Type Type Outdoor Units Nominal Capacity U SingleOutdoor Unit Type Type S-26PK2U6 Connectable outdoor unit lineup This booklet is the operating instructions for indoor unit. Regarding th\ e outdoor unit, see the operating instructions supplied with the outdoor unit.
2 CONTENTS Page PRODUCT INFORMATION ........................................................................................................... 2 ALERT SYMBOLS......................................................................................................................... 2 INSTALLATION LOCATION ...........................................................................................................3 ELECTRICAL REQUIREMENTS .................................................................................................. 3 SAFETY INSTRUCTIONS.............................................................................................................3 OPERATION CONDITION ............................................................................................................4 NAMES OF PARTS ....................................................................................................................... 5 Timer Remote Controller (Optional parts) ..................................................................................... 5 Refer to the Operating Instructions attached to the optional Timer Remote Controller. High-spec Wired Remote Controller (Optional parts) .................................................................... 5 Refer to the Operating Instructions attached to the optional High-spec Wired Remote Controller. Wireless Remote Controller (Supplied parts) ................................................................................ 5 See the section “WIRELESS REMOTE CONTROLLER” for details. ADJUSTING AIRFLOW DIRECTION ............................................................................................ 6 SPECIAL REMARKS .................................................................................................................... 7 CARE AND CLEANING ................................................................................................................ 8 TROUBLESHOOTING .................................................................................................................. 9 CHECK BEFORE REQUIRING SERVICES ................................................................................ 10 TIPS FOR ENERGY SAVING ..................................................................................................... 10 WIRELESS REMOTE CONTROLLER ........................................................................................ 11 SPECIFICATIONS ....................................................................................................................... 21 PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate of the unit. Model No. _________________________________ Serial No. _______________________ Date of purchase ______________________________________________________________ Dealer’s address ______________________________________________________________ Phone number ________________________________________________________________ ALERT SYMBOLS The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. NOTE NOTE NOTE 85464609338010_01_EN.fm Page 2 Wednesday, September 2, 2015 12:09 PM
3 INSTALLATION LOCATION • We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. ELECTRICAL REQUIREMENTS SAFETY INSTRUCTIONS • Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help. • This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions. • Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse. • Do not install the air conditioner where excessively high heat-generating objects are placed. Avoid:To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa. All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details. It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fire. Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring. Wiring must be done by a qualified electrician. To warm up the system, the power mains must be turned on at least five (5) hours before operation. Leave the power mains ON unless you will not be using this appliance for an extended period. Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time. • Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than the specified type may cause product damage, burst and injury etc. • Never touch the unit with wet hands. • Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous. • Do not use this appliance in a potentially explosive atmosphere. • This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case. • To prevent possible hazards from insulation failure, the unit must be grounded. • Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning. • In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair. • Check for a leaking refrigerant! Refrigerant gas may produce a toxic gas if it comes in contact with fire. NOTE 85464609338010_01_EN.fm Page 3 Wednesday, September 2, 2015 12:09 PM
4 OPERATION CONDITION • For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing. • Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency. • Do not sit or step on the unit. You may fall down accidentally. • Do not turn the air conditioner on and off from the power mains switch. Use the ON/ OFF operation button. • Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed. • Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You may get injured. • Keep the fire alarm and the air outlet at least 5 feet (1.5 m) away from the unit. • Do not let children play with the air conditioner. • Do not cool or heat the room too much if babies or invalids are present. • Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged. • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. FCC Caution: To assure continued compliance, follow the attached installation instructions. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes. Use this air conditioner under the following temperature range. Single Split System * DBT: Dry bulb temperature * WBT: Wet bulb temperature Temperature range (°F/°C)Indoor Outdoor *DBT *WBT *DBT *WBT CoolingMax. 90/32 77/25 115/46 –/– Min. 64/17.8 57/14 14/-10 –/– HeatingMax. 86/30 –/– 75/24 64/17.8 Min. 61/16 –/– -4/-20 -4/-20 85464609338010_01_EN.fm Page 4 Wednesday, September 2, 2015 12:09 PM
5 NAMES OF PARTS Timer Remote Controller (Optional parts) High-spec Wired Remote Controller (Optional parts) Wireless Remote Controller (Supplied parts) INDOOR UNIT Refer to the Operating Instructions attached to the optional Timer Remote Controller. Refer to the Operating Instructions attached to the optional High-spec Wired Remote Controller. See the section “WIRELESS REMOTE CONTROLLER” for details. TIMER OPERATION STANDBY Air intake Receiver Air outlet Emergency Operation button NOTE (CZ-RTC4) NOTE (CZ-RTC3) (CZ-RTC5) NOTE 85464609338010_01_EN.fm Page 5 Wednesday, September 2, 2015 12:09 PM
6 ADJUSTING AIRFLOW DIRECTION „Wall mounted type (K2) Vertical directions (automatic) Confirm that the remote controller has been turned on. Press the FLAP button to start the flap moving up and down. If you want to stop the flap movement and to direct the air in the desired direction, press the FLAP button again. In the cool mode, do not direct the flap down and move out of the cooling zone “A”, otherwise, condensation may drip on to the floor. Zone ‘‘A’’ is the recommended flap position for cooling. When operating continuously in the fixed airflow direction setting for about an hour, the airflow direction is automatically controlled and the flap position is changed. The airflow direction may be different from the display on the remote controller. Do not move the flap with your hands. Horizontal directions (manual) The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the left or right. Indoor unit Zone ‘‘B’’ for heating Zone ‘‘A’’ for cooling 85464609338010_01_EN.fm Page 6 Wednesday, September 2, 2015 12:09 PM
7 SPECIAL REMARKS ‘‘DRY’’ Operation Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating. The fan speed is set to ‘‘LO.’’ automatically, and cannot be adjusted. ‘‘DRY’’ operation is not possible if the outdoor temperature is 59°F (15°C) or less. Heating Performance Since this air conditioner utilizes outside air for heating, its heating performance deteriorates as outside temperature decreases. (Due to heat pump system) It will take some time until the room becomes warmer after heating operation started. (Due to hot air circulation system in order to heat a whole room) Defrosting This appliance may start defrosting operation to melt frost form in the outdoor unit during long hour heating operation mode. The indoor unit fan will stop for about 5 to 10 minutes at this time. Heating StandbyThe remote controller shows “ ” (Heating standby) on the display in the following mode and the indoor unit fan may be controlled. When operation started (Indoor unit fan stops for maximum 6 minutes.) When Thermostat activated When defrosting (Indoor unit fan stops.) Remote Control SensorThe temperature sensor in the indoor unit normally senses the room temperature and can also sense the ambient temperature of the remote controller. For the details, consult the shop you purchased. Should the power failure occurs while the unit is runningWhen the unit automatically resumes operation after temporary power failure, it uses the same settings before the power was cut off. 85464609338010_01_EN.fm Page 7 Wednesday, September 2, 2015 12:09 PM
8 CARE AND CLEANING Do not attempt to clean inside the unit by yourself. Refer to the section “Care and Cleaning” in the Installation Instructions. 1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning. 2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard. Air intake and outlet side (Indoor unit)Clean the air intake and outlet side of the indoor unit with a vacuum cleaner brush, or wipe them with a clean soft cloth. If these parts are stained, use a clean cloth moistened with a mild liquid detergent. When cleaning the air outlet side, be careful not to force the vanes out of place. 1. Never use solvents or harsh chemicals when cleaning the indoor unit. Do not wipe plastic parts using very hot water. 2. Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts. 3. The internal coil and other components of the outdoor unit must be cleaned every year. Consult your dealer or service center. Air filterThe air filter collects dust and other particles from the air and should be cleaned at regular intervals when the filter indication ( ) on the display of the remote controller (wired type) shows that the filter needs cleaning. If the filter gets blocked, the efficiency of the air conditioner drops greatly. The frequency with which the filter should be cleaned depends on the environment in which the unit is used. Wipe with a soft cloth. (If it is very dirty, use a cloth moistened with water.) NOTE 85464609338010_01_EN.fm Page 8 Wednesday, September 2, 2015 12:09 PM
9 TROUBLESHOOTING If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. INDOOR UNIT Symptom Cause Noise Sound like streaming water during operation or after operation Sound of refrigerant liquid flowing inside unit Sound of drainage water through drain pipe Cracking noise during operation or when operation stops.Cracking sound due to temperature changes of parts Odor Discharged air is smelled during operation.Indoor odor components, cigarette odor and cosmetic odor accumurated in the air conditioner and its air is discharged. Unit inside is dusty. Consult your dealer. Dewdrop Dewdrop gets accumurated near air discharge during operationIndoor moisture is cooled by cool wind and accumulated by dewdrop. Fog Fog occurs during operation in cooling mode. (Places where large amounts of oil mist exist at restaurants.) Cleaning is necessary because unit inside (heat exchanger) is dirty. Consult your dealer as technical engineering is required. During defrost operation Fan is rotating for a while even though operation stops. Fan rotating makes operation smoothly. Fan may sometimes rotate because of drying heat exchanger due to settings. Wind-direction changes while operating. Wind-direction setting cannot be made. Wind-direction cannot be changed. When air discharge temperature is low or during defrost operation, horizontal wind flow is made automatically. Flap position is occasionally set up individually. When wind-direction is changed, flap operates several times and stops at designated position.When wind-direction is changed, flap operates after searching for standard position. Dust Dust accumulation inside indoor unit is discharged. At the initial high-speed operation, the fan may sometimes rotate faster (for 3 to 30 minutes) than the setting speed.This is for operation check in order to confirm whether the fan motor rotation is within use range. 85464609338010_01_EN.fm Page 9 Wednesday, September 2, 2015 12:09 PM
10 CHECK BEFORE REQUIRING SERVICES If your air conditioner still does not work properly although you checked the points as described above, first stop the operation and turn off the power switch. Then contact your dealer and report the serial number and symptom. Never repair your air conditioner by yourself since it is very dangerous for you to do so. You also report if the inspection mark and the letters E, F, H, L, P in combination with the numbers appear on the LCD of the remote controller. TIPS FOR ENERGY SAVING Avoid • Do not block the air intake and outlet of the unit. If either is obstructed, the unit will not work well, and may be damaged. Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room. Do Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit. To prevent conditioned air from escaping, keep windows, doors and any other openings closed. Should the power fail while the unit is running If the power supply for this unit is temporarily cut off, the unit will automatically resume operation once power is restored using the same settings before the power was interrupted. Symptom Cause Remedy Air conditioner does not run at all although power is turned on.Power failure or after power failure Press ON/OFF operation button on remote controller again. Operation button is turned off. Switch on power if breaker is turned off. If breaker has been tripped, consult your dealer without turning it on. Fuse blow out. If blown out, consult your dealer. Poor cooling or heating performanceAir intake or air discharge port of indoor and outdoor units is clogged with dust or obstacles.Remove dust or obstruction. Wind speed switch is set to “Low”. Change to “High” or “Strong”. Improper temperature settings Refer to “TIPS FOR ENERGY SAVING”. Room is exposed to direct sunlight in cooling mode. Doors and /or windows are open. Air filter is clogged. Refer to “CARE AND CLEANING”. Too much heat sources in room in cooling mode.Use minimum heat sources and in a short time. Too many people in room in cooling mode. Reduce temperature settings or change to “High” or “Strong”. NOTE 85464609338010_01_EN.fm Page 10 Wednesday, September 2, 2015 12:09 PM