38 OPM-4240 / OPM-4240R 39 Infinitely Expandable Go to "Control" in menu bar → PC Tracking → Auto in order to run "Tracking Auto" window. y In case alignment doesn't work through "Tracking Auto" command, y users can tune finely through "Tracking Manual". Go to "Control" of menu bar → PC Tracking → Manual or press "Ctrl+M" using keyboard. "Tracking Manual" window enables users to set Frequency, Phase, y LineStart and PixelStart. When "Tracking Manual" window is on display, users cannot display y "Picture Control" window. Even when "Tracking Manual" window is on display, selecting 'ID' is y available by clicking right button of mouse. (Refer to "5.5 PDP ID Setting".) Detail adjustment steps are as follows. y 1) Tune "Phase" until the vertical lines are clearly adjusted.. 2) Tune "LineStart" to adjust vertical alignment. "PixelStart" for horizontal alignment. 3) Adjust "Frequency" if alignment is still wrong. If you adjust "Frequency", repeat step 1) and 2) to fit alignment. Adjustable range is as follows -The range of "Frequency" you can adjust is -50 to 50 -The range of "Phase" you can adjust is 0 to 31 -The range of "Linestart" you can adjust is -23 to 10 -The range of "Pixelstart" you can adjust is -50 to 40 Click "Exit" button or press "Ctrl+X" using keyboard to close "Tracking Manual" window. y 5.12. PC Tracking Alignment adjustment is available when input source is PC. y Tracking Manual Window 5.13. Timer Control Users can decide the time of turning on or off MPDP set by timer control. y To use this function, click Menu -> Control-> Timer Control or use 'Ctrl +T' keys from the keyboard. y How to set the time of power on or off. y I. Select Hour and Minutes of turn on or off - II. Select once for one time use and Daily for daily use, then click 'Start' - III. Power on or off signal will be transmitted to MPDP at the time of user set. - Time Dialog must be activated to use Timer function y Timer Control Dialog
40 OPM-4240 / OPM-4240R 41 Infinitely Expandable 5.14. BiC Control You can control BIC functions related with burn-in compensation. y Please select "Menu → Control → BIC Control" or "Ctrl+B" to start BIC control. y Select one of BIC mode, BYPASS mode, REGENERAION mode and ANTI IMAGE STICKING mode and y click “EXE” to control Burn-in compensation function. 1.BICOn/Off BiC Mode:1) Activate BIC function to reduce burn-in effect. (BIC function On) BYPaSS Mode:2) Deactivate BIC function, but BIC board keeps recording burn-in history.(BIC function Off) 2.Additionalcompensation rEgEnEra TiOn Mode:1) Compensate burn-in effect by displaying a reversal image of the current burn-in image. anTi iMagE S TiCking 2) Mode : In case you find serious Burn-in effect in a certain area, select "Anti Image Sticking Mode," White Stripe pattern scans whole screen to make uniform screen condition to eliminate unequally burned pixels. White bar pattern in the screen moves horizontally. Precaution for MVP device * MVP devices can be used with APL off mode and it can be selected by MSCS control. When APL is turned off, brightness is slightly decreased. MVP (Multi Video Processor) device? It is a multi channel image processing system using digital signal proce\ ssing methods. It converts analog composite videos to digital format, save in \ a memory and process the saved image data without any frame loss and image deterioration to communicate with a computer. ※ For more information for APL, please contact with the dealers or agent where you purchased the MPDP. BIC Control
42 OPM-4240 / OPM-4240R 43 Infinitely Expandable Phosphor Update function changes phosphor value. y If you cannot have satisfactory compensation result by adjusting Deterioration function, you can change phosphor value. Deterioration function adjusts deterioration range for Red, Green and Blue respectively. y Set up Test pattern-Red, Green, Blue and "SCREEN" external image source, to control Deterioration.1) Adjust Deterioration range for Red, Green and Blue respectively. 2) Adjustable range is 70% to 130% and initial value is 100%. In case surrounding pixels are brighter than burn-in image, increase the present value and surrounding pixels are darker, decrease the value. BiC status indicator Red: Malfunction, a small red square continuously blinks at the lower right corner of the screen. Green: Normal, a small green square blinks several times and disappears at the same position. Yellow: BIC related events such as Update, a small yellow square continuously blinks at the same position. ※Caution - Screen may fade in and out when power on. It is a process of BIC initial update. It is not a malfunction of MPDP. - Do not use BIC function during moving images. (BYPASS MODE) - Brightness can be decreased for burn-in compensation. Lower luminescence. Higher luminescence. Activation status between 70% ~ 130% Burn-in-Compensation Control Method User can select a color (Red, Green or Blue) for compensation from Deterioration Menu in the BIC 1. Control menu. When you find disturbing Burn-in effect on your screen, please select a proper value from Data 1, 2. Data 2, Data 3 and Data 4 in the phosphor change option and execute. (It takes 1 ~2 seconds) Please select Data 1 when Burn-in pattern is brighter than surrounding screen area and select Data 4 for darker Burn-in pattern than surrounding screen area If the selected value does not cause enough compensation result, repeat above process up to 4 3. times, and select the most satisfactory value and fix the value. If the compensation result is still not good enough, you can fine tune Red, Green and Blue colors one 4. by one in Deterioration Menu Please control Green, Blue and Red sequentially. 5. Initial value is set as 100% and it can be controlled within the range of 70% ~ 130%. In case of Burn-in pattern is brighter than surrounding area, select lower value (under 100%) and 6. higher value (over 100%) for darker Burn-in pattern. (Please find optimal value through changing the value by 10 %) Sequentially control Red, Green, and Blue, examine the result with white pattern and repeat the 7. process. If you do not have satisfactory result after repeating above process, please change the value of 8. Green, Red and Blue by 1% until you can find the best result. In case, the compensation result is still unsatisfactory, REGENERATION Mode and ANTI IMAGE 9. STICKING Mode may be applied for better result. Adjusting White Balance after BIC control process may improve compensation result. 10. BiC intervals and effect Burn-In-Compensation function is executed automatically. However, the level of burn-in effect may vary due to input sources and display period. In case, you can notice disturbing level of visual burn-in effect, we recommend to execute additional compensation functions. It is very effective to execute such compensation after 3months of daily 24hour use. If you do compensation prior to 3 months, the compensation result may be less effective. If you have any questions or need further information, please contact us or the dealers where you purchased the product.
44 OPM-4240 / OPM-4240R 45 Infinitely Expandable How to Control BiC 1.MSCS 1) MSCS and MPDP must be always connected. 2) If MSCS command is executed prior to the BIC command, the BIC command will be executed again one hour later. 3) Turn off the energy save mode of the computer. 4) The compensation for undesirable burn-in effect is made automatically when BIC function is executed. If the compensation result is not satisfactory, use additional Burn-in compensation function in MSCS. (Please see page 39 for further information.) BIC B/D IP B/D MPDP BIC B/D MPDP BIC B/D MPDP BIC B/D MPDP IP B/D IP B/D IP B/D 2. The other control program (beside MSCS) Refer to BIC protocol and program guide to insert BIC control program into the MPDP control program. ※BIC board is installed inside of MPDP unit. ※ BIC function is working hourly by MSCS. MSCS Connect to RS-232C in MPDP 3. MF-Controller 1) If you want to use the other MPDP control program beside MSCS and you cannot integrate BIC control program into the MPDP control program, you can use MF-Controller. 2) The numbers of MPDP units should be set by MF-Controller. 3) The MF-Controller connected to MPDP must be always turned on. 4) During BIC function is being executed, all the commands are ignored. Even the remote controller is not responding. If BIC command is given during the command from MF-Controller is being executed, the BIC command will be executed one hour later. 5) Please refer to the next page for MF Controller configuration. BIC B/D IP B/D MPDP BIC B/D MPDP BIC B/D MPDP BIC B/D MPDP IP B/D IP B/D IP B/D PWR DVDCVBSY/CB.CA T.P. STB PC DVI DTV ※BIC board is installed inside of MPDP unit. ※ BIC function is working hourly by MSCS. MSCS RS232 MF-Controller RS232
46 OPM-4240 / OPM-4240R 47 Infinitely Expandable MF-Controller configuration method 1. Connect power. 2. Connect female D-sub to the Com port in a computer. 3. Connect male D-sub to the RS-232C port in MPDP. 4. Set the number of the connected MPDP units in advance. The number can be set only by the Remote controller. 5. Set the switch at REMOCON side DC 5~9V BOOSTER REMOCONTO PDP FROM PC 아답터 연결잭(5V 1A 사용) MPDP연결PC연결 BOOSTER 또는 REMOCON 선택 스위치 ※note Select BOOSTER for a booster and BIC functions. Select REMOCON for a remote controller and BIC functions. DC 5~9V BOOSTERREMOCONTO PDP FROM PC BOOSTER REMOCON 6. Start with press "GO" button. 7. Configure the number of horizontally installed MPDP units at first. Press "LEFT" and "RIGHT" buttons to begin horizontal configuration. (◀ ▶) Press the button for the number of the MPDP units and the same number of LEDs are turned on from the right side. (In case of 2X2, press button.) 2sets are selected. Horizontal & Vertical configuration The LEDs are turned on one by one from the rightmost as the number increases from 1 to 7 and turned off from the rightmost for the number 8 or higher. Horizontal configuration 7sets Horizontal configuration 8sets Horizontal configuration 10sets 가로설정상태설정상태 나타냄 POWER ON POWER OFF INPUT SELECT PC DVD AUTO R GBWGO VIDEO S-VIDEO DVI DTV BROAD CAST NORMALCOMMAND TEST PATTERN PDP REMOTE CONTROL MPDP Enter S1S2S3S4 S5S6S7SCR R G BW S1S2S3S4 S5S6S7SCR 1234 5678 90
48 OPM-4240 / OPM-4240R 49 Infinitely Expandable 8. Press "UP" and "DOWN" buttons to begin vertical configuration.(▲▼) Press the button for the number of the MPDP units and the same number of LEDs are turned on from the right side. (In case of 2X2, press button.) 2sets are selected. 9. Press "GO" button to finish configuration mode. (Configuration finish & save) 10. The rightmost LED (T.P.) is turned on when MF Controller starts BIC communication. If this LED blinks, there are some communication errors. The LED is turned off after the communication. 가로설정상태설정상태 나타냄 POWER ON POWER OFF INPUT SELECT PC DVD AUTO R GBWGO VIDEO S-VIDEO DVI DTV BROAD CAST NORMALCOMMAND TEST PATTERN PDP REMOTE CONTROL MPDP Enter S1S2S3S4 S5S6S7SCR POWER ON POWER OFF INPUT SELECT PC DVD AUTO R GBWGO VIDEO S-VIDEO DVI DTV BROAD CAST NORMALCOMMAND TEST PATTERN PDP REMOTE CONTROL MPDP Enter S1S2S3S4 S5S6S7SCR Horizontal configuration configuration Horizontal configuration configuration Horizontal configuration configuration R G BW S1S2S3S4 S5S6S7SCR 1234 5678 90 5.15. Orion PDP Home Page logon and Version information In order to move to Orion PDP's website, go to "Help" of menu bar → "OrionDisplay HomePage". y Orion PDP Home Page Logon Go to "Help" of menu bar → "About" to check MSCS. y Checking MSCS Version
50 OPM-4240 / OPM-4240R 51 Infinitely Expandable Introduction1. This document contains the communication protocol between PDP and its control devices such as computer for better use of the product. However, it does not include detailed technical matters. It rather focuses on t\ he brief functional explanation and communication protocol. ID:1 Controller Tx/Rx Line ID:2ID:N-1ID:N ID:N+1 ID:N+N ID:(M-2)N+1 ID:(M-2)N+N ID:(M-1)N ID:(M-1)N+2 ID:(M-1)N+N-1ID:MXN ※ Connection formation can be vary based on the configuration or user setting. Communication Setting1.1. Transmission & Reception type: Asynchronous Serial Communication -Connection type: Daisy Chain -Baudrate : 115200 -Data Bits : 8 -Parity : None -Stop Bits : 1 -Flow Control : None - Protocol Format2. Send To PDP2.1. STXCommandLengthDataETX 1 byte1 byte1 byteVariable1 byte IDOther Data 1 byteN byte This is how to send commands to PDP. Only the set of the designated ID is working according to the "Comman\ d." But, if the "ID" value is "0", all -MPDP sets are working according to command as "Broad Cast".STX(0x02): The initial code. It means the beginning of Protocol. (Fixed value) -Command: Code for actual operation. (Variable) -Length: the length of "Data" area. (Variable: 0~255) -Data: the areas for "ID" and the other Data (Variable) -ID: Set identification (0~255) (Variable) -ETX(0x03): The end of the code. (Fixed value) - 6. MSCS Protocol Receive From PDP2.2. STXCMDLengthDataCheck SumETX 1 byte1 byte1 byteVariable1 byte1 byte IDOther Data 1 byteN byte Response by a certain command from the designated set among MPDP sets. The difference from "Send to PDP" is "Check sum". -STX(0x02): The initial code. It means the beginning of Protocol. (Fixed value) -Command: Code for actual operation. (Variable) -Length: the length of "Data" area. (Variable: 0~255) -Data: the areas for "ID" and the other Data (Variable) -ID: Set identification (0~255) (Variable) -Check Sum: Add all the values in "Data" area. Then perform "NOT" operation. (Variables) -ETX(0x03): The end of the code. (Fixed value)) - Command3. Power On3.1. Power On command for MPDP -Command Code: 0x40 -One way communication (Send to PDP) -Data: ID(1 byte) -E.g.) Power On Condition for MPDP ID No.1 set - STXCMDLengthIDETX Value0x020x400x010x010x03 1.Clicktherightbuttonofthemousetoselectdesiredset 2.SelectONEPDPandclick"On" Power Off3.2. Power off command for MPDP -PDP will be turn into “Stand-by” mode after execute this command -Command Code: 0x41 -One way communication (Send to PDP) -Data: ID(1 byte) -E.g.) Power Off Condition for MPDP ID No.1 set - STXCMDLengthIDETX Value0x020 x410x010x010x03 1.Clicktherightbuttonofthemousetoselectdesiredset 2.SelectONEPDPandclick"Off" ID : 1 ID : 4 ID : 7 ID : 2 ID : 5 ID : 8 ID : 3 ID : 6 ID : 9 ➊ ➋ ID : 1 ID : 4 ID : 7 ID : 2 ID : 5 ID : 8 ID : 3 ID : 6 ID : 9 ➊ ➋
52 OPM-4240 / OPM-4240R 53 Infinitely Expandable Multi-Scale3.3. Screen expansion command for MPDP -Command Code -0xDD (DVI), 0xDE (PC), 0xDF (DTV), 0xE0 (DVD), 0xE1(S-Video), 0xE2 (Video)One way communication (Send to PDP) -Data: ID (1 byte) +X/Y(1 byte) + P(1 byte) -X: the number of horizontally installed MPDP Y: the number of vertically installed MPDP P: the location of expanded scaleX/Y: upper position 4bits - X (Max: 15), lower position 4bits - Y (Max: 15)e.g.) 0x44 for 4 x 4 screens, 0xFF for 15 x 15 screense.g.) Screen expansion condition of 2x2 among 3x3 MPDP 3 sets. (Input-Source - DVI) - STXCMDLengthIDX/YPETX Value0x020xDD0x030x010x220x010x03 Value0x020xDD0x030x020x220x020x03 Value0x020xDD0x030x040x220x030x03 Value0x020xDD0x030x050x220x040x03 1.Select"DVI"from"SourceSelect" 2.Drag2x2bymouse ※Incaseexecute"①"→"②"or Play"①"→"③",allMPDPsetsareturnedinto1:1screen.-"X/Y"valueis0x22,"P"valueis"0x01" Information3.4. Information display command for set (Input source and Resolution) -The information will be displayed on the selected PDP -after this command. (OSD display)Command Code: 0x42 -One way communication (Send to PDP) -Data: ID (1 byte) -e.g.) Set information check for MPDP ID No.1 - STXCMDLengthIDETX Value0x020x420x010x010x03 1.Selectdesiredsetbyclickingtherightbuttonofthemouse. 2.SelectONEPDPandClick"INFO"ontherightside ※IfyouneedtochecktheallMPDPsets,selectALLPDPatthestep"①"and executestep"②" -ExecuteBroadCastwiththe"ID"areavalueof"0x00" Auto-Power Mode3.5. The command for set or cancel automatic power on when AC power is connected -Command Code: 0x62(Set), 0x63(Cancel) -One way communication (Send to PDP) -Data: ID (1 byte) -e.g.) Set or Cancel Auto Power mode for the ID No. 1 MPDP - STXCMDLengthIDETXSTXCMDLengthIDETX Value0x020x620x010x010x030x020x630x010x010x03 IfyouneedtosetorcancelAutoPowerModeforallMPDP,setthevalueofIDareaas"0x00".※ Global Offset3.6. Command for removing the image data of the seam area (set) for better \ continuous image or displaying the image data of the seam area (cancel)\ . -Command Code: 0x74 (Set), 0x73 (Cancel) -One way communication (Send to PDP) -Data: ID (1 byte) -e.g.) Set or cancel Global Offset command for MPDP ID No. - STXCMDLengthIDETXSTXCMDLengthIDETX Value0x020 x 740x010x010x030x020x730x010x010x03 IfyouneedtosetorcancelGlobalOffsetModeforallMPDP,setthevalueofIDareaas"0x00".※ Test Pattern3.7. Command for check the set condition with the internal test pattern. -Command Code: 0x57 (Red), 0x58 (Green), 0x59 (Blue), 0x5A (White), 0x5B (Screen) -To return to main screen: 0x5B -One way communication (Send to PDP) -Data: ID (1byte) -e.g.) Set or cancel White Test Pattern for MPDP ID No. 1 - STXCMDLengthIDETXSTXCMDLengthIDETX Value0x020x5A0x010x010x030x020x5B0x010x010x03 IfyouneedtosetorcancelTestPatternforallMPDP,setthevalueofIDareaas"0x00".※ Position3.8. Command for moving screen position of Component(DTV, DVD), Composite(Video), and S-Video image input. -Command Code: 0x6E (Up), 0x6F (Down), 0x70 (Left), 0x71 (Right),\ 0x72 (Center) -Data: ID(1 byte) -e.g.) Move to the left side or cancel for MPDP ID No.1 - STXCMDLengthIDETXSTXCMDLengthIDETX Value0x020x700x010x010x030x020x720x010x010x03 IfyouwanttosetthepositionofallMPDP,setthevalueofIDareaas"0x00".※ ID : 1 ID : 4 ID : 7 ID : 2 ID : 5 ID : 8 ID : 3 ID : 6 ID : 9 ➊ ➌ ➋ ID : 1 ID : 4 ID : 7 ID : 2 ID : 5 ID : 8 ID : 3 ID : 6 ID : 9 ➊➌ ➋
54 OPM-4240 / OPM-4240R 55 Infinitely Expandable Tracking Mode3.9. Automatic or Manual screen alignment or open previous configuration at PC RGB Mode. -Command Code: -0x4A (Auto-tracking), 0x4B (Get Tracking Values), 0x4C (Frequency- tracking), 0x4D (Phase-tracking), 0x4E (Line-Start tracking), 0x4F (Pixel-Start tracking)Protocol format for each command -:Get Tracking Values - Two way communication (Send to PDP, Receive from PDP)①SendtoPDP STXCMDLengthIDETX 1 byte1 byte1 byte1 byte1 byte Data: ID(1 byte) -②ReceiveFromPDP STXCMDLengthDataCheck SumETX 1 byte1 byte1 byte5 byte1 byte1 byte Data: ID(1 byte) + Frequency(1 byte) + Phase(1 byte) + LineStart(\ 1 byte) + PixelStart(1 byte) -Check Sum: Add all the values in "Data" area. Then perform "NOT" operation. -: Auto-tracking - One way communication (Send to PDP) STXCMDLengthDataETX 1 byte1 byte1 byte1 byte1 byte Data: ID (1 byte) -If you want to execute Auto-tracking for all MPDP, set the value of ID area as "0x00". -: Frequency-tracking - One way communication (Send to PDP) STXCMDLengthDataETX 1 byte1 byte1 byte2 byte1 byte Data: ID(1 byte) + Frequency(1 byte) -If you want to execute Frequency-tracking for all MPDP, set the value of ID area as "0x00". -: Phase-tracking - One way communication (Send to PDP) STXCMDLengthDataETX 1 byte1 byte1 byte2 byte1 byte Data: ID(1 byte) + Phase (1 byte) - If you want to execute Phase-tracking for all MPDP, set the value of ID area as "0x00". -: LineStart - tracking - One way communication (Send to PDP) STXCMDLengthDataETX 1 byte1 byte1 byte2 byte1 byte Data: ID(1 byte) + LineStart (1 byte) - If you want to execute LineStart-tracking for all MPDP, set the value of ID area as "0x00". -: PixelStart-tracking - One way communication (Send to PDP) STXCMDLengthDataETX 1 byte1 byte1 byte2 byte1 byte Data: ID(1 byte) + PixelStart (1 byte) -If you want to execute PixelStart-tracking for all MPDP, set the value of ID area as "0x00". - Input Mode Change3.10. This can be used for additional input mode change. -Command Code: 0x44 (DVI), 0x45 (PC), 0x46 (DTV), 0x47 (DVD), 0x4\ 8 (S-Video), 0x49 (Video) -One way communication (Send to PDP) -Data: ID (1 byte) -e.g.) ID No.1: Mode change for DVI, ID No. 2: Video - STXCMDLengthIDETXSTXCMDLengthIDETX Value0x020x440x010x010x030x020x490x010x020x03 IfyouwanttosetthesameinputmodeforallMPDP,setthevalueofIDareaas"0x00".※ APL Control3.11. APL On/Soft/Off -Command Code: 0x54 (APL On), 0x55 (APL Soft), 0x56 (APL Off) -One way communication (Send to PDP) -Data: ID (1byte) -e.g.) APL On after APL off of MPDP ID No.1 - STXCMDLengthIDETXSTXCMDLengthIDETX Value0x020x560x010x010x030x020x540x010x020x03 IfyouwanttosetthesameAPLstatusforallMPDP,setthevalueofIDareaas"0x00".※ Video Zoom Control3.12. Default level of Video Zoom is "5", and can be set for "1" to "9". -Command Code: 0x6D -One way communication (Send to PDP) -Data: ID (1byte) + Zoom (1 byte) -e.g.) 9 times Zoom for MPDP ID No. 1 - STXCMDLengthDataETX Value0x020x6D0x020x010x090x03 IfyouwanttoapplythesameVideozoomlevelforallMPDP,setthevalueofIDareaas"0x00".※ Color Temperature3.13. Normal mode 9300k, Studio mode 3600k -Generally, Normal mode is recommended. Studio mode is suitable for broadcasting. \ (Default: Normal mode) -Command Code: 0xB3 (Normal), 0xB4 (Studio: broadcasting) -One way communication (Send to PDP) -Data: ID (1 byte) -e.g.) Mode change from Studio mode to Normal mode for MPDP ID No.1 - STXCMDLengthIDETXSTXCMDLengthIDETX Value0x020xB40x010x010x030x020xB30x010x010x03 IfyouwanttohavethesamecolortemperatureforallMPDP,setthevalueofIDareaas"0x00".※
56 OPM-4240 / OPM-4240R 57 Infinitely Expandable Elapsed Time3.14. Command for finding out how long the set was actually used. -Command code: 0x78 -Protocol Format: - two way communication (Send to PDP, Receive from PDP) -*SendtoPDP STXCMDLengthIDETX 1 byte1 byte1 byte1 byte1 byte Data: ID(1 byte) -*ReceiveFromPDP STXCMDLengthDataCheck SumETX 1 byte1 byte1 byte7 byte1 byte1 byte Data: ID(1 byte) + Elapsed Time Data(5 byte) -Elapsed Time Data -Data 0: position for hundred thousand, Data 1: position for ten thousand\ Data 2: position for thousand, Data 3: position for hundred Data4: position for ten, Data5: position for oneCheck sum: Add all the values in "Data" area. Then perform "NOT" operation. - IP Serial Number3.15. Apply serial number of IP board to each set and identify the number again. -Command Code: 0x75 (Get S/N), 0x76 (Set S/N) -Protocol Format for each command -①GetSerialNumber-Twowaycommunication(SendtoPDP,ReceiveFromPDP)* Send to PDP STXCMDLengthIDETX 1 byte1 byte1 byte1 byte1 byte Data: ID(1 byte) -* Receive From PDP STXCMDLengthDataCheck SumETX 1 byte1 byte1 byte9 byte1 bytebyte Data: ID(1 byte) + S/N(8 byte) -Check Sum: Add all the values in "Data" area. Then perform "NOT" operation. - ②SetSerialNumber-Onewaycommunication(SendtoPDP) STXCMDLengthDataETX 1 byte1 byte1 byte1 byte1 byte Data: ID(1 byte) + S/N(8 byte) - Auto-Calibration3.16. Adjust ADC Gain and Offset at 100% 8 -Color input. It is available only with PC, DTV and DVD i\ nput modes. -Caution: This command is available only with PC, DTV and DVD input modes at 100% \ 8 -Color input signal. -Command Code: 0x80 -One way communication (Send to PDP) -Data: ID (1 byte) -e.g.) Auto-Calibration for MPDP ID No. 1 - STXCMDLengthIDETX Value0x020x800x010x010x03 IfyouwanttoexecuteAuto-CalibrationforallMPDP,setthevalueofIDareaas"0x00".※ Default Data Load (Picture Control Data)3.17. Return every adjusted value to default values. All the built-in values are applied. -Caution: Existing Picture Control Data will be lost with this command. -Command Code: 0x81 -One way communication (Send to PDP) -Data: ID (1 byte) -e.g.) Execute Default Data Load for MPDP ID No. 1 - STXCMDLengthIDETX Value0x020x810x010x010x03 IfyouwanttoexecuteDefaultDataLoadforallMPDP,setthevalueofIDareaas"0x00".※ BIC (Burn-In Compensation)3.18. The purpose of BIC function is reducing Burn-in effect. Please refer to detailed explanation and register for BIC document\ . -Command Code: 0x6A -Protocol Format -1.SetData-Onewaycommunication(SendtoPDP) STXCMDLengthDataETX 1 byte1 byte1 byten byte1 byte Data - IndexIDSet Data BitRead /WriteAddressBIC Data Size1 byte1 byte1 byte1 byte4 byte ValueVariable0x040x00VariableVariable SetDataBits:8,16,32bitsettingarea.Currently32bitconfigurationisused.※(8bit:0x01,16bit:0x02,32bit:0x04)BICdata:Accordingto"SetDataBit"areaconfiguration,Datalengthisvary.※(8bit:1byte,16bit:2byte,32bit:4byte)IfyouwanttoexecuteBICcommandforallMPDP,setthevalueofIDareaas"0x00".※ Length -: Length value is 0x08 for 32bit configuration.Lengthvaluefor"SetDataBit"areaconfiguration※ Length8bit16bit32bit 0x050x060x08 2.GetData-Twowaycommunication(SendtoPDP,ReceiveFromPDP)* Send to PDP STXCMDLengthDataETX 1 byte1 byte1 byten byte1 byte Data - IndexIDSet Data BitRead /WriteAddress Size1 byte1 byte1 byte1 byte ValueVariable0x040x01Variable Length -: Length value is 0x04, because currently only 32bit configuration is applied.* Receive From PDP STXCMDLengthDataCheck SumETX 1 byte1 byte1 byten byte1 byte1 byte