25. Replace the cleaned doctor blade assembly in the hopper. Install the lower brace first inserting the tail through the cartridge wall and under the copper contact. Install the doctor blade next making sure the lip is facing down and the blade fits over the alignment pins correctly. OKIDATA B2500 MFP TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS © 2010 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only. UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact [email protected] www.uninetimaging.com 26. Replace the upper metal brace and the two screws. Clean the developer roller with a clean lint free dry cloth. We do not recommend any chemicals be used at this time.27. Replace the developer roller into the cartridge. The long metal shaft side goes to the gear side of the hopper. Downloaded From ManualsPrinter.com Manuals
28. Replace the metal bushings on both sides of the developer roller shaft. 29. Replace the screw and holder on the gear side of the developer roller shaft.30. Replace the screw, holder and contact on the contact side of the developer roller shaft. OKIDATA B2500 MFP TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS © 2010 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only. UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact [email protected] www.uninetimaging.com Downloaded From ManualsPrinter.com Manuals
31. Clean and replace the conductive grease on the developer roller and the feed roller shafts. Note that the feed roller contacts also run to the doctor blade. This helps ensure that the toner is properly charged throughout the hopper.32. Fill the hopper with the Okidata B2500 toner. Replace the fill plug. 33. Replace all the gears on the hopper as shown. 34. Place the two halves together and install the two metal pins. OKIDATA B2500 MFP TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS © 2010 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only. UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact [email protected] www.uninetimaging.com Downloaded From ManualsPrinter.com Manuals
35. Install the metal plates and screws. 36. Install the drum cover if available. It needs to be taped in place. Use a brightly colored tape so the user will notice it.37. After the cartridge has been tested and bagged, tape the Key card to the top of the bag so the user will see it. This key card is installed into the printer separately from the cartridge. OKIDATA B2500 MFP TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS © 2010 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only. UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact [email protected] www.uninetimaging.com Downloaded From ManualsPrinter.com Manuals
PRINTING A TEST PAGE: The simplest way to test a cartridge is to make a copy: 1. To do this place the original face down in the feeder. 2. Press the copy key, number of copies desired and the start key. CLEANING THE SCANNER: If copied and transmitted pages come out with marks on the pages, but the reports are clean, the scanner is dirty: 1. To clean the scanner, open the scanner cover. 2. Wipe the scanner window down with a lint-free cloth moistened with Isopropyl alcohol. REPETITIVE DEFECT CHART: OPC Drum 75mm Developer Roller 50mm PCR 29mm OKIDATA B2500 MFP TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS © 2010 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only. UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact [email protected] www.uninetimaging.com Downloaded From ManualsPrinter.com Manuals