Nitsuko Digital System Businesscom Ds01 Hardware Manual
Have a look at the manual Nitsuko Digital System Businesscom Ds01 Hardware Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 57 Nitsuko manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Installing a Modem You can connect a modem to the AUX Module serial port for remote program- ming and diagnostics. To connect the AUX Module to a modem (DCE): 1.Plug a DB9-DB25 adaptor into the AUX port. The DB9 must be female. 2.Connect one end of the RS-232 cable to the adaptors DB25 connector. OR Connect a 25-pin null-modem cable into the adaptors DB25 connector. 3.Connect the other end of the RS-232 cable to a DCE-DCE adaptor. Skip Step #3 when using a null modem cable. 4.Connect the other end of the DCE-DCE adaptor or null modem cable to the modems serial port. See Figure 17. To set the AUX serial port baud rate (from extension 300/port 00): 1.Lift handset + press ICM. 2.Dial: #, 0. 3.Dial a digit to select baud rate: 0 = 300, 1 = 1200, 2 = 2400 3 = 4800, 4 = 9600, 5 = 19.2KDATA FORMAT Data bits = 8 Stop bits = 1 Baud rate =1200 Parity = none FIGURE 17 5. SMDR AND TERMINAL PROGRAMMING
Installing Battery Backup (Optional) One Valcom VPB-260 battery backup unit provides a CEU with short-term power (2 hours - max.) during a commercial AC power failure. One per CEU max. To install the VPB-260: 1.Mount the VPB-260 on the MDF backboard within 3 of the CEU. Follow manufacturer’s mounting instructions. 2.Power down the CEU’s power supply. 3.Plug the VPB-260 3-pin female plug into the 3-pin male AUX POWER connector on the CEU. 4.Plug the VPB-260 power cord into a dedicated 120VAC outlet. 01853L22 Do not use the outlet dedicated to CEU power supply. 120 V AC Outlet To Power Supply Battery Backup 3 max. Note: Follow manufacturers instructions when connecting the battery backup unit. 1 2 3 + 12 V DC common - 12 V DC FIGURE 18
6. BATTERY BACKUP AND POWER FAILURE TELEPHONES N1853 - 32 BLK YELRED GRN BLUWHT BLK YELRED GRN BLUWHT BLK YELRED GRN BLU WHT 4 3 2 1 PFT 4CO Installing Power Failure (PF) Telephones (Optional) The first circuit in each 4CO or 4CO/CND module (1/5, 9/13, 17/21) provides a PF cut-through relay. Each PF relay, corresponding modular jacks, and cross-connec- tions redirect a CO line to a 500/2500 single line telephone for full incoming\outgoing operation during an AC power outage. To install a PF telephone: 1.Install 3 modular jacks for each line requiring PF operation. Label jacks CO Line, PF Line, and PF Telephone. (The PF Line jack must be 6-conductor). 2.Connect GRN/RED from the CO Line jack to GRN/RED of the PF Line jack using one-pair x-connect cable. See Figure 19. 3.Connect WHT/BLU from the PF Line jack to GRN/RED of the PF Telephone jack using one-pair x-connect cable. 4.Connect Telcos RJ11C to the Line jack using a standard line cord. 5.Connect the PF Line jack to the 4CO modules modular connector (lines 1/5, 9/13, 17/21) using a 6-conductor line cord. 6.Connect a PF telephone to the PF Telephone jack with a standard line cord. To test power failure cut-through at a PF telephone: 1.Power down the system. 2.Lift the handset on the PF telephone. (You should hear dial tone.) Place a call from the PF telephone. FIGURE 19
Installing the Digital Door Box The Digital Door Box (P/N 88545) provides one-button signaling and intercom. Up to four Digital Door Boxes can be installed at extensions 310, 311, 322, and 323 only. Each Digital Door Box provides a distinctive chime signal. Any keyset can receive any/all chime signals. To install the Digital Door Box: 1.Snap open the Door Box case. 2.Punch down one end of a two-pair twisted station cable on the extension block as shown below. Digital Door Boxes have the same cabling requirements as Electronic Single Line telephones. 3.Run the station cable through the hole in the back of the Door Box. When wall mounting, use the two holes in the base of the door box for the mounting screws. 4.Strip the free conductors back about 1/2 inch and connect to the Door Box terminals as shown in Figure 20. 5.Snap the Door Box cover onto the base. 6.In E-Extensions, E3-Class of Service(or Program 18Ioption COS from the administrator’s telephone), assign each Door Box extension Class of Service 28. In QV- Peripheral Ports, Door Box Alert Time(or Program 18Ioption DB from the administrator’s telephone), set which extensions should receive Door Box Chimes. Refer to your Software Administrators Manual for additional programming details. Installing the Relay Box The Relay Box (P/N 88546) provides three normally-open relays which typically are used to activate an electric strike door-unlock mechanism for an entrance door equipped with a Digital Door Box. After responding to a Door Box chime signal, the user activates the relay (opening a door) by pressing the FTR button on the telephone dialpad. To Install the Relay Box: 1.Punch down a 4-conductor station cable to extension 309. 2.Terminate the other end of the cable to a modular jack. See Figure 21. 3.Plug in a 4-conductor line cord into the modular jack. Plug the other end into the Relay Box. 1853 - 30A FIGURE 20
Operation To activate relays from a multibutton set: 1.Lift handset to answer the Door Box chimes. If you have a Door Box Hotline or Call Coverage key, you can press it instead. OR Place call to Door Box.You can press Intercom and dial the Door Box extension number. You can also press your Door Box Hotline or Call Coverage key (if you have one). 2.Talk to the visitor at the door. 3.Press and hold FTR. The relay activates as long as you hold down the FTR key (up to 60 seconds). 4.Hang up when you are through. To activate relays from a single line set: 1.Lift handset to answer the Door Box chimes. ORPlace call to Door Box (i.e., dial Door Box extension number). 2.Talk to the visitor at the door. 3.Dial *. Do not hold down the * key. The relay activates for six seconds and then automatically releases. 4.Hang up when you are through. Programming Notes:At extension 309, set E2- Circuit Type to X. Set E3- Class of Service to 28. At each extension that should activate the strike: In QV-Peripheral Ports (Alert Programming), enable Alert for each Door Box. If an extension receives chimes, it can acti- vate the associated Relay Box strike. N1853 - 31 37 38 39 40TT TR RT RRWhite/Blue Blue/White White/Orange Orange/White FIGURE 21 7. DOOR BOX AND RELAY BOX
CEU Specifications: Lines Stations Main CEU 8 24 Expansion CEU #1 8 24 Expansion CEU #2 8 24 Total 24 72 System Capacity: Power Failure Cut-Through Circuit 1 per CO Module Talk Timeslots (Intercom/lines) Non-blocking DTMF Tone Duration (manual dial) 256 ms on/128 ms off DTMF Tone Duration (speed dial) 128 ms on/128 ms off Internal Page Zones 7 (and all-call) External Page Zones 1 output per Main & Exp.CEU #1 External Control Relay Circuits 1 set of contacts per Main & Exp. CEU #1 Electrical Specifications: AC Input: 115 V AC +/- 10% @ 57-63 Hz, Dedicated 15 A circuit. Grounding Requirements: Copper wire, continuous, No. 14 AWG, or larger. Power Requirements: 75-100VA maximum (per CEU) - Refer to power supply label. Heat Dissipation: 256 BTU per CEU AUX Relay Contact Rating: External Zone Paging: Max. Load: 60 mA @ 30 V DC Output Impedance: 600 OHMS 10 mA @ 90 V AC Max. Output: +3 dBm Maximum Initial Contact Resistance: 50 m OHMS Background Music\Music on Hold: Input Impedance: 100 K OHMS Maximum Input: -10 dBm Cable Requirements: From CEU to Keysets or ASI: Four-conductor (two-pair twisted station cable) 1,500 feet w/No. 26 AWG 2,000 feet w/No. 24 AWG 2,500 feet w/No. 22 AWG From ASI to connected OPX device: 100 feet using 22 AWG four-conductor. Use 25-pair cables with Type 57 female connectors to connect to Station Modules. Use four conductor modular line cords to connect to CO Modules. Use multiconductor riser cables to an Intermediate Distribution Frame (IDF) when required.
8. SPECIFICATIONS Mechanical Specifications Width Height Depth Weight CEU 14 5/16 9 1/4 3 3 lb, 11 oz 39.2 cm 23.7 cm 7.6 cm 1.7 kg CO Module 6 3/4 6 3/4 1 1/2 1 lb 17.1 cm 17.1 cm 3.8 cm .5 kg Station Module 6 3/4 6 3/4 1 1/2 1 lb 17.1 cm 17.1 cm 3.8 cm .7 kg Power Supply 2 13/16 5 2 3/4 3 lbs 7.2 cm 12.7 cm 7.0 cm 1.4 kg Keysets 3 1/2 7 1/2 10 1/8 2.7 lb 8.9 cm 19.1 cm 25.8 cm 1.3 kg NOTE:Weight of CEU is with modules not installed. Environmental Specifications Refer to the Standard Practices Manual (P/N N2710STD01). FCC Registration Information Model: DS01 Manufacturer: Nitsuko America Load number (DOC) 20 FCC Part 15 Registration: Class A Sample FCC Registration Number: 1ZDTHA-65325-MF-E *Total load per CEU not to exceed 24. Facility USOC Jack REN/Service Interface Type of Interface Connector Code Code 2-Wire Loop RJ11C 2.5B 02LS2 Item Load Factor* Circuit Type Notes Display keyset 1 02 1 port, auto-ID DSS console 2 06 2 port, auto-ID Dual-ASI 3 51 2 port, no auto-ID Standard keyset 1 01 1 port, auto-ID ASI 1 51 1 port, no auto-ID ESL 1 00 1 port, auto-ID Door Box 1 X 310/311/322/323 only Relay Box 1 X Installed at 309 only Relay for 310 cannot be used Data Module 1 01 1 port, no auto-ID Load Factor Table
Description Part Number Common Equipment Power Supply .............................................................................................................60001 CEU - (includes: 1 Common Equipment Unit base + 1 - 60001 + RFI beads, no modules) ................................................................................................................88600 4x12 Kit (no phones): .................................................................................................88601 1 - 88600 (includes: 1 - CEU + 1 - 60001 + RFI beads) 1 - 88511 4 CO Module, 1 - 88521 12 Station Module (digital) 4x12 Kit (8 phones): ...................................................................................................88691 1 - 88601 (includes: 1 - 88600 + 88511 + 88521 + RFI beads) 1 - 88663 HF Display Telephone, 7 - 88661 HF Telephones 12x36 Kit (10 phones): ...............................................................................................88692 2 - 88601 (includes: 1 - 88600 + 88511 + 88521 + RFI beads) 1 - 88511 4 CO Module 1 - 88521 12 Station Module 1 - 88625 AUX Module 1 - 88529 SAUX Module (includes: 1 - 88587 6 8-conductor cable) 2 - 88663 HF Display Telephones 8 - 88661 HF Telephones Modules 4 CO Module ..............................................................................................................88511 4 CO Caller ID Module ...............................................................................................88512 12 Station Module (digital) ..........................................................................................88521 AUX Module ...............................................................................................................88625 SAUX Module (includes: 1 - 88587 6 8-conductor cable) ..........................................88529 XAUX Expansion AUX Module (includes: 1 - 88588 3 8-conductor cable) ................88526 12SCU/VMU Voice Module Unit (12 stations + 3 VMU ports) ....................................88522 12SCU/PCU Peripheral Control Unit Module (12 stations + 2 - 2500 circuits) ...........88530 AUX/SAUX Kit: ...........................................................................................................88695 1 - 88625 AUX Module 2 - 88529 SAUX Module (includes: 1 - 88587 6 8-conductor cable) Software CEU base software upgrade - latest release - (2 IC chips) ........................................88608 AUX module software upgrade - latest release - (2 IC chips) ....................................88628 SAUX/XAUX module software upgrade - latest release (1 IC chip) ...........................88589 Upload/Download Program - (1 floppy disk) ...............................................................88217 Station Equipment 16 Button Non-HF Telephone (Taupe) .......................................................................88660 16 Button HF Telephone (Taupe) ...............................................................................88661 16 Button HF Display Telephone (Taupe) ..................................................................88663 16 Button Non-HF Telephone (Graphite) ...................................................................88670 16 Button HF Dual LED Telephone (Graphite) ...........................................................88671 16 Button HF Display Dual LED Telephone (Graphite) ..............................................88673 Digital Single Line Telephone (Taupe) .......................................................................88650 Digital Single Line Telephone (Graphite)....................................................................88676
9. PARTS LIST CEU/Power Supply Site Requirements Choose a central site for the MDF plywood backboard, with- in 7’ of a dedicated AC outlet and 25’ of earth ground. Allow space for multiple CEU’s and power supplies. CEU’s must be located within 3’ of each other. Power supplies must be located within 6’ of the CEU and within 6’ of a dedicated AC outlet. See Figure 1. Allow space for telco and station connectors, all ancillary equipment (ie; BGM/MOH source, voice mail, external pag- ing equipment), and expansion. Refer to Nitsuko’s Standard Practices Manual (P/N N2710STD01) for general environ- ment and site specifications. Mounting the CEU 1. Locate CEU mounting screws. Drill holes (2) in backboard using a 1/8” drill bit. Refer to mounting dimensions in Figure 2 (or use template, if installed). 2. Install CEU mounting screws (2) in holes. See Figure 2. Use screw gauges to set proper screw depth. (Screws & gauges are in plastic packet). 3. Hang CEU on mounting screws. 4. Drill lower CEU screw hole using a 1/8” drill bit. See Figure 2. Install and tighten screw. 5. Ground each CEU using #12 AWG (or larger) ground wire to earth ground. FIGURE 1 Description Part Number Other Station Equipment DSS Console (Taupe) ................................................................................................88655 DSS Console (Graphite) .............................................................................................88675 Digital Door Box..........................................................................................................88545 Relay Box ...................................................................................................................88546 ASI - Analog Station Interface (single port w/DTMF receiver) ....................................88749 Dual Port ASI (dual port w/DTMF receivers) ..............................................................88750 Wall Mount Kit (Taupe) ...............................................................................................88679 Wall Mount Kit (Dark Gray).........................................................................................88779 Wall Mount Hanger .....................................................................................................88680 Data Products Data Module ...............................................................................................................88400 Dataport PCB .............................................................................................................88460 Modem Pooling PCB ..................................................................................................88465 Mini Data Unit .............................................................................................................89408 Mini Data Unit Power Supply ......................................................................................89409 DCE-DCE Adaptor......................................................................................................89079 Replacement Parts K1 Handset (Taupe) ...................................................................................................88685 K1H Handset (Dark Gray) ..........................................................................................88775 Handset Cord (6 foot) ..............................................................................................88685-6 Handset Cord (9 foot) ..............................................................................................88685-9 Handset Cord (13 foot) ..........................................................................................88685-13 Line Cord (7 foot) ....................................................................................................88686-7 Line Cord (14 foot) ................................................................................................88686-14 Line Cord (25 foot) ................................................................................................88686-25 8-conductor 6 cable (AUX-SAUX w/2CEUs or SAUX-XAUX w/3 CEUs) .................88587 8-conductor 3 cable (AUX-XAUX w/3 CEUs) ............................................................88588 Installation Equipment Plywood Backboard 1 66M1-50 connecting block(s) 1 25-pair cable(s) 1 22/24 AWG 4-conductor twisted-pair station cable 1 Cross-connect wire 1 Bridging clips 1 Modular jack (1 per station) 1 Modular line cords (1 per CO line) 1 Ground wire (1 per CEU) 1 RJ11C Telco interface (1 per CO line) 1 AC surge protector (1 per CEU) 1 1 Item not supplied by Nitsuko America.
9. PARTS LIST Description Part Number Other Station Equipment DSS Console (Taupe) ................................................................................................88655 DSS Console (Graphite) .............................................................................................88675 Digital Door Box..........................................................................................................88545 Relay Box ...................................................................................................................88546 ASI - Analog Station Interface (single port w/DTMF receiver) ....................................88749 Dual Port ASI (dual port w/DTMF receivers) ..............................................................88750 Wall Mount Kit (Taupe) ...............................................................................................88679 Wall Mount Kit (Dark Gray).........................................................................................88779 Wall Mount Hanger .....................................................................................................88680 Data Products Data Module ...............................................................................................................88400 Dataport PCB .............................................................................................................88460 Modem Pooling PCB ..................................................................................................88465 Mini Data Unit .............................................................................................................89408 Mini Data Unit Power Supply ......................................................................................89409 DCE-DCE Adaptor......................................................................................................89079 Replacement Parts K1 Handset (Taupe) ...................................................................................................88685 K1H Handset (Dark Gray) ..........................................................................................88775 Handset Cord (6 foot) ..............................................................................................88685-6 Handset Cord (9 foot) ..............................................................................................88685-9 Handset Cord (13 foot) ..........................................................................................88685-13 Line Cord (7 foot) ....................................................................................................88686-7 Line Cord (14 foot) ................................................................................................88686-14 Line Cord (25 foot) ................................................................................................88686-25 8-conductor 6 cable (AUX-SAUX w/2CEUs or SAUX-XAUX w/3 CEUs) .................88587 8-conductor 3 cable (AUX-XAUX w/3 CEUs) ............................................................88588 Installation Equipment Plywood Backboard 1 66M1-50 connecting block(s)1 25-pair cable(s)1 22/24 AWG 4-conductor twisted-pair station cable1 Cross-connect wire1 Bridging clips1 Modular jack (1 per station)1 Modular line cords (1 per CO line)1 Ground wire (1 per CEU)1 RJ11C Telco interface (1 per CO line)1 AC surge protector (1 per CEU)1 1 Item not supplied by Nitsuko America.