    							Installing a Modem
    You can connect a modem to the AUX Module serial port for remote program-
    ming and diagnostics.
    To connect the AUX Module to a modem (DCE):
    1.Plug a DB9-DB25 adaptor into the AUX port. The DB9 must be female.
    2.Connect one end of the RS-232 cable to the adaptors DB25 connector.
    OR Connect a 25-pin null-modem cable into the adaptors DB25 connector.
    3.Connect the other end of the RS-232 cable to a DCE-DCE adaptor.
    Skip Step #3 when using a null modem cable.
    4.Connect the other end of the DCE-DCE adaptor or null modem cable to the 
    modems serial port. See Figure 17.
    To set the AUX serial port baud
    rate (from extension 300/port 00):
    1.Lift handset + press ICM.
    2.Dial:  #, 0.
    3.Dial a digit to select baud rate:
    0 = 300, 1 = 1200, 2 = 2400
    3 = 4800, 4 = 9600, 5 = 19.2KDATA FORMAT
    Data bits = 8
    Stop bits = 1
    Baud rate =1200
    Parity = none
    FIGURE 17
    5. SMDR AND TERMINAL PROGRAMMING 
    						
    							Installing Battery Backup (Optional)
    One Valcom VPB-260 battery backup unit provides a CEU with short-term power
    (2 hours - max.) during a commercial AC power failure. One per CEU max.
    To install the VPB-260:
    1.Mount the VPB-260 on the MDF backboard within 3 of the CEU. Follow
    manufacturer’s mounting instructions.
    2.Power down the CEU’s power supply.
    3.Plug the VPB-260 3-pin female plug into the 3-pin male AUX POWER
    connector on the CEU.
    4.Plug the VPB-260 power cord into a dedicated 120VAC outlet.
    01853L22
    Do not use the
    outlet dedicated to
    CEU power supply. 120 V AC
    Outlet To Power Supply
    Battery
    Backup
    3 max.
    Note: Follow manufacturers
              instructions when connecting
              the battery backup unit.
    1 2 3
    + 12 V DC
    common
    - 12 V DC
    FIGURE 18 
    						
    							6. BATTERY BACKUP AND POWER FAILURE TELEPHONES
    N1853 - 32
    BLK YELRED
    GRN
    BLUWHT
    BLK YELRED
    GRN
    BLUWHT
    BLK YELRED
    GRN
    BLU
    WHT
    4    3    2    1   PFT
    4CO
    Installing Power Failure (PF) Telephones (Optional)
    The first circuit in each 4CO or 4CO/CND module (1/5, 9/13, 17/21) provides a PF
    cut-through relay. Each PF relay, corresponding modular jacks, and cross-connec-
    tions redirect a CO line to a 500/2500 single line telephone for full incoming\outgoing
    operation during an AC power outage.
    To install a PF telephone:
    1.Install 3 modular jacks for each line requiring PF operation. Label jacks CO Line, 
    PF Line, and PF Telephone. (The PF Line jack must be 6-conductor).
    2.Connect GRN/RED from the CO Line jack to GRN/RED of the PF Line jack using 
    one-pair x-connect cable. See Figure 19.
    3.Connect WHT/BLU from the PF Line jack to GRN/RED of the PF Telephone jack 
    using one-pair x-connect cable.
    4.Connect Telcos RJ11C to the Line jack using a standard line cord.
    5.Connect the PF Line jack to the 4CO modules modular connector (lines 1/5, 9/13,
    17/21) using a 6-conductor line cord.
    6.Connect a PF telephone to the PF Telephone jack with a standard line cord.
    To test power failure cut-through at a PF telephone:
    1.Power down the system.
    2.Lift the handset on the PF telephone. (You should hear dial tone.) Place a call
    from the PF telephone.
    FIGURE 19 
    						
    							Installing the Digital Door Box
    The Digital Door Box (P/N 88545) provides one-button signaling and intercom. Up to four
    Digital Door Boxes can be installed at extensions 310, 311, 322, and 323 only. Each Digital
    Door Box provides a distinctive chime signal. Any keyset can receive any/all chime signals.
    To install the Digital Door Box:
    1.Snap open the Door Box case.
    2.Punch down one end of a two-pair twisted station cable on the extension block as shown
    below. 
    Digital Door Boxes have the same cabling requirements as Electronic Single Line
    telephones.
    3.Run the station cable through the hole in the back of the Door Box. When wall mounting,
    use the two holes in the base of the door box for the mounting screws.
    4.Strip the free conductors back about 1/2 inch and connect to the Door Box terminals as
    shown in Figure 20.
    5.Snap the Door Box cover onto the base.
    6.In E-Extensions, E3-Class of Service(or Program 18Ioption COS from the
    administrator’s telephone), assign each Door Box extension Class of Service 28. In
    QV- Peripheral Ports, Door Box Alert Time(or Program 18Ioption DB from the
    administrator’s telephone), set which extensions should receive Door Box Chimes.
    Refer to your Software Administrators Manual for additional programming details.
    Installing the Relay Box
    The Relay Box (P/N 88546) provides three normally-open relays which typically are used to
    activate an electric strike door-unlock mechanism for an entrance door equipped with a
    Digital Door Box. After responding to a Door Box chime signal, the user activates the relay
    (opening a door) by pressing the FTR button on the telephone dialpad.
    To Install the Relay Box:
    1.Punch down a 4-conductor station cable to extension 309.
    2.Terminate the other end of the cable to a modular jack. See Figure 21.
    3.Plug in a 4-conductor line cord into the modular jack. Plug the other end into the
    Relay Box.
    1853 - 30A
    FIGURE 20 
    						
    							Operation
    To activate relays from a multibutton set:
    1.Lift handset to answer the Door Box chimes. 
    If you have a Door Box Hotline or Call Coverage key, you can press it
    instead.
    OR
    Place call to Door Box.You can press Intercom and dial the Door Box extension number. You can 
    also press your Door Box Hotline or Call Coverage key (if you have one).
    2.Talk to the visitor at the door.
    3.Press and hold FTR.
    The relay activates as long as you hold down the FTR key
    (up to 60 seconds).
    4.Hang up when you are through.
    To activate relays from a single line set:
    1.Lift handset to answer the Door Box chimes.
    ORPlace call to Door Box (i.e., dial Door Box extension number).
    2.Talk to the visitor at the door.
    3.Dial *.
    Do not hold down the * key. The relay activates for six seconds and then
    automatically releases.
    4.Hang up when you are through.
    Programming Notes:At
    extension 309, set E2-
    Circuit Type to X. Set E3-
    Class of Service to 28.
    At each extension that
    should activate the strike: In
    QV-Peripheral Ports (Alert
    Programming), 
    enable Alert for each Door
    Box. If an extension
    receives chimes, it can acti-
    vate the associated 
    Relay Box strike.
    N1853 - 31
    37
    38
    39
    40TT
    TR
    RT
    RRWhite/Blue
    Blue/White
    White/Orange
    Orange/White
    FIGURE 21
    7. DOOR BOX AND RELAY BOX 
    						
    							CEU Specifications: Lines Stations
    Main CEU 8 24
    Expansion CEU #1 8 24
    Expansion CEU #2 8 24
    Total 24 72
    System Capacity:
    Power Failure Cut-Through Circuit 1 per CO Module
    Talk Timeslots (Intercom/lines) Non-blocking
    DTMF Tone Duration (manual dial) 256 ms on/128 ms off
    DTMF Tone Duration (speed dial) 128 ms on/128 ms off
    Internal Page Zones 7 (and all-call)
    External Page Zones 1 output per Main & Exp.CEU #1
    External Control Relay Circuits 1 set of contacts per Main & Exp. CEU #1
    Electrical Specifications:
    AC Input:
    115 V AC +/- 10% @ 57-63 Hz, Dedicated 15 A circuit.
    Grounding Requirements:
    Copper wire, continuous, No. 14 AWG, or larger.
    Power Requirements:
    75-100VA maximum (per CEU) - Refer to power supply label.
    Heat Dissipation:
    256 BTU per CEU
    AUX Relay Contact Rating: External Zone Paging:
    Max. Load: 60 mA @ 30 V DC Output Impedance: 600 OHMS
    10 mA @ 90 V AC Max. Output: +3 dBm
    Maximum Initial Contact Resistance:
    50 m OHMS
    Background Music\Music on Hold:
    Input Impedance: 100 K OHMS
    Maximum Input: -10 dBm
    Cable Requirements: From CEU to Keysets or ASI:
    Four-conductor (two-pair twisted station cable)
    1,500 feet w/No. 26 AWG
    2,000 feet w/No. 24 AWG
    2,500 feet w/No. 22 AWG
    From ASI to connected OPX device:
    100 feet using 22 AWG four-conductor.
    Use 25-pair cables with Type 57 female connectors to connect to Station Modules.
    Use four conductor modular line cords to connect to CO Modules.
    Use multiconductor riser cables to an Intermediate Distribution Frame (IDF) 
    when required. 
    						
    							8. SPECIFICATIONS
    Mechanical Specifications
    Width Height Depth Weight
    CEU 14 5/16 9 1/4 3 3 lb, 11 oz
    39.2 cm 23.7 cm 7.6 cm 1.7 kg
    CO Module 6 3/4 6 3/4 1 1/2 1 lb
    17.1 cm 17.1 cm 3.8 cm .5 kg
    Station Module 6 3/4 6 3/4 1 1/2 1 lb
    17.1 cm 17.1 cm 3.8 cm .7 kg
    Power Supply 2 13/16 5 2 3/4 3 lbs
    7.2 cm 12.7 cm 7.0 cm 1.4 kg
    Keysets  3 1/2 7 1/2 10 1/8 2.7 lb
    8.9 cm 19.1 cm 25.8 cm 1.3 kg
    NOTE:Weight of CEU is with modules not installed.
    Environmental Specifications
    Refer to the Standard Practices Manual (P/N N2710STD01).
    FCC Registration Information
    Model: DS01
    Manufacturer: Nitsuko America
    Load number (DOC) 20
    FCC Part 15 Registration: Class A
    Sample FCC Registration Number: 1ZDTHA-65325-MF-E
    *Total load per CEU not to exceed 24.
    Facility
    USOC Jack REN/Service Interface
    Type of Interface Connector Code Code
    2-Wire Loop RJ11C 2.5B 02LS2
    Item Load Factor* Circuit Type Notes
    Display keyset 1 02 1 port, auto-ID
    DSS console 2 06 2 port, auto-ID
    Dual-ASI 3 51 2 port, no auto-ID
    Standard keyset 1 01 1 port, auto-ID
    ASI 1 51 1 port, no auto-ID
    ESL 1 00 1 port, auto-ID
    Door Box 1 X 310/311/322/323 only
    Relay Box 1 X Installed at 309 only
    Relay for 310 cannot be used
    Data Module 1 01 1 port, no auto-ID
    Load Factor Table 
    						
    							Description Part Number
    Common Equipment
    Power Supply .............................................................................................................60001
    CEU - (includes: 1 Common Equipment Unit base + 1 - 60001 + RFI beads,
    no modules) ................................................................................................................88600
    4x12 Kit (no phones): .................................................................................................88601
    1 - 88600 (includes: 1 - CEU + 1 - 60001 + RFI beads)
    1 - 88511 4 CO Module, 1 - 88521 12 Station Module (digital)
    4x12 Kit (8 phones): ...................................................................................................88691
    1 - 88601 (includes: 1 - 88600 + 88511 + 88521 + RFI beads)
    1 - 88663 HF Display Telephone, 7 - 88661 HF Telephones
    12x36 Kit (10 phones): ...............................................................................................88692
    2 - 88601 (includes: 1 - 88600 + 88511 + 88521 + RFI beads)
    1 - 88511 4 CO Module
    1 - 88521 12 Station Module
    1 - 88625 AUX Module
    1 - 88529 SAUX Module (includes: 1 - 88587 6 8-conductor cable)
    2 - 88663 HF Display Telephones
    8 - 88661 HF Telephones
    Modules
    4 CO Module ..............................................................................................................88511
    4 CO Caller ID Module ...............................................................................................88512
    12 Station Module (digital) ..........................................................................................88521
    AUX Module ...............................................................................................................88625
    SAUX Module (includes: 1 - 88587 6 8-conductor cable) ..........................................88529
    XAUX Expansion AUX Module (includes: 1 - 88588 3 8-conductor cable) ................88526
    12SCU/VMU Voice Module Unit (12 stations + 3 VMU ports) ....................................88522
    12SCU/PCU Peripheral Control Unit Module (12 stations + 2 - 2500 circuits) ...........88530
    AUX/SAUX Kit: ...........................................................................................................88695
    1 - 88625 AUX Module
    2 - 88529 SAUX Module (includes: 1 - 88587 6 8-conductor cable)
    Software
    CEU base software upgrade - latest release - (2 IC chips) ........................................88608
    AUX module software upgrade - latest release - (2 IC chips) ....................................88628
    SAUX/XAUX module software upgrade - latest release (1 IC chip) ...........................88589
    Upload/Download Program - (1 floppy disk) ...............................................................88217
    Station Equipment
    16 Button Non-HF Telephone (Taupe) .......................................................................88660
    16 Button HF Telephone (Taupe) ...............................................................................88661
    16 Button HF Display Telephone (Taupe) ..................................................................88663
    16 Button Non-HF Telephone (Graphite) ...................................................................88670
    16 Button HF Dual LED Telephone (Graphite) ...........................................................88671
    16 Button HF Display Dual LED Telephone (Graphite) ..............................................88673
    Digital Single Line Telephone (Taupe) .......................................................................88650
    Digital Single Line Telephone (Graphite)....................................................................88676 
    						
    							9. PARTS LIST
    CEU/Power Supply Site Requirements
    Choose a central site for the MDF plywood backboard, with-
    in 7’ of a dedicated AC outlet and 25’ of earth ground.
    Allow space for multiple CEU’s and power supplies. CEU’s
    must be located within 3’ of each other. Power supplies
    must be located within  6’ of  the CEU and within 6’ of a
    dedicated AC outlet. See Figure 1.
    Allow space for telco and station connectors, all ancillary
    equipment (ie; BGM/MOH source, voice mail, external pag-
    ing equipment), and expansion. Refer to Nitsuko’s Standard
    Practices Manual (P/N N2710STD01) for general environ-
    ment and site specifications.
    Mounting the CEU
    1. Locate CEU mounting screws. Drill holes (2) in
    backboard using a 1/8” drill bit. Refer to mounting
    dimensions in Figure 2 (or use template, if installed). 
    2. Install CEU mounting screws (2) in holes. See Figure 2.
    Use screw gauges to set proper screw depth.
    (Screws & gauges are in plastic packet). 
    3. Hang CEU on mounting screws.
    4. Drill lower CEU screw hole using a 1/8” drill bit.
    See Figure 2. Install and tighten screw.
    5. Ground each CEU using #12 AWG (or larger) 
    ground wire to earth ground.
    FIGURE 1
    Description Part Number
    Other Station Equipment
    DSS Console (Taupe) ................................................................................................88655
    DSS Console (Graphite) .............................................................................................88675
    Digital Door Box..........................................................................................................88545
    Relay Box ...................................................................................................................88546
    ASI - Analog Station Interface (single port w/DTMF receiver) ....................................88749
    Dual Port ASI (dual port w/DTMF receivers) ..............................................................88750
    Wall Mount Kit (Taupe) ...............................................................................................88679
    Wall Mount Kit (Dark Gray).........................................................................................88779
    Wall Mount Hanger .....................................................................................................88680
    Data Products
    Data Module ...............................................................................................................88400
    Dataport PCB .............................................................................................................88460
    Modem Pooling PCB ..................................................................................................88465
    Mini Data Unit .............................................................................................................89408
    Mini Data Unit Power Supply ......................................................................................89409
    DCE-DCE Adaptor......................................................................................................89079
    Replacement Parts
    K1 Handset (Taupe) ...................................................................................................88685
    K1H Handset (Dark Gray) ..........................................................................................88775
    Handset Cord (6 foot) ..............................................................................................88685-6
    Handset Cord (9 foot) ..............................................................................................88685-9
    Handset Cord (13 foot) ..........................................................................................88685-13
    Line Cord (7 foot) ....................................................................................................88686-7
    Line Cord (14 foot) ................................................................................................88686-14
    Line Cord (25 foot) ................................................................................................88686-25
    8-conductor 6 cable (AUX-SAUX w/2CEUs or SAUX-XAUX w/3 CEUs) .................88587
    8-conductor 3 cable (AUX-XAUX w/3 CEUs) ............................................................88588
    Installation Equipment
    Plywood Backboard
    1
    66M1-50 connecting block(s)
    1
    25-pair cable(s)
    1
    22/24 AWG 4-conductor twisted-pair station cable
    1
    Cross-connect wire
    1
    Bridging clips
    1
    Modular jack (1 per station)
    1
    Modular line cords (1 per CO line)
    1
    Ground wire (1 per CEU)
    1
    RJ11C Telco interface (1 per CO line)
    1
    AC surge protector (1 per CEU)
    1
    1
    Item not supplied by Nitsuko America. 
    						
    							9. PARTS LIST
    Description Part Number
    Other Station Equipment
    DSS Console (Taupe) ................................................................................................88655
    DSS Console (Graphite) .............................................................................................88675
    Digital Door Box..........................................................................................................88545
    Relay Box ...................................................................................................................88546
    ASI - Analog Station Interface (single port w/DTMF receiver) ....................................88749
    Dual Port ASI (dual port w/DTMF receivers) ..............................................................88750
    Wall Mount Kit (Taupe) ...............................................................................................88679
    Wall Mount Kit (Dark Gray).........................................................................................88779
    Wall Mount Hanger .....................................................................................................88680
    Data Products
    Data Module ...............................................................................................................88400
    Dataport PCB .............................................................................................................88460
    Modem Pooling PCB ..................................................................................................88465
    Mini Data Unit .............................................................................................................89408
    Mini Data Unit Power Supply ......................................................................................89409
    DCE-DCE Adaptor......................................................................................................89079
    Replacement Parts
    K1 Handset (Taupe) ...................................................................................................88685
    K1H Handset (Dark Gray) ..........................................................................................88775
    Handset Cord (6 foot) ..............................................................................................88685-6
    Handset Cord (9 foot) ..............................................................................................88685-9
    Handset Cord (13 foot) ..........................................................................................88685-13
    Line Cord (7 foot) ....................................................................................................88686-7
    Line Cord (14 foot) ................................................................................................88686-14
    Line Cord (25 foot) ................................................................................................88686-25
    8-conductor 6 cable (AUX-SAUX w/2CEUs or SAUX-XAUX w/3 CEUs) .................88587
    8-conductor 3 cable (AUX-XAUX w/3 CEUs) ............................................................88588
    Installation Equipment
    Plywood Backboard
    1
    66M1-50 connecting block(s)1
    25-pair cable(s)1
    22/24 AWG 4-conductor twisted-pair station cable1
    Cross-connect wire1
    Bridging clips1
    Modular jack (1 per station)1
    Modular line cords (1 per CO line)1
    Ground wire (1 per CEU)1
    RJ11C Telco interface (1 per CO line)1
    AC surge protector (1 per CEU)1
    1
    Item not supplied by Nitsuko America. 
    						
    All Nitsuko manuals Comments (0)

    Related Manuals for Nitsuko Digital System Businesscom Ds01 Hardware Manual