Netgear Rn316 Readynas 600 Series 6 Bay Hardware Manual
Here you can view all the pages of manual Netgear Rn316 Readynas 600 Series 6 Bay Hardware Manual. The Netgear manuals for NAS Systems are available online for free. You can easily download all the documents as PDF.
Page 151
Environmental requirements: •Operating temperature: 0 to 40°C (32° to 104°F) •Operating humidity: 20 to 80% relative humidity (noncondensing) •Storage temperature: –20 to 70°C (–4 to 158°F) •Storage humidity: 5 to 95% relative humidity (noncondensing) •Software-controlled 120 mm chassis cooling fan Certifications: FCC Class B, CE Class B, RoHS, VCCI Class B, CCC, MIC, BIS ReadyNAS 626X Technical Specifications The ReadyNAS 626X storage system meets the following technical specifications: General: •Intel...
Page 152
Power consumption: •BTU at full power supply utilization: 100W •In operation: 70.5W •Power off (Wake On LAN): 310 mW •Power off: 264 mW Electrical: •Internal 200W server-rated AC power supply •Input: 100–240 VAC, 50/60 Hz Environmental requirements: •Operating temperature: 0 to 40°C (32° to 104°F) •Operating humidity: 20 to 80% relative humidity (noncondensing) •Storage temperature: –20 to 70°C (–4 to 158°F) •Storage humidity: 5 to 95% relative humidity (noncondensing) •Software-controlled 120 mm chassis...
Page 153
•Two 10 GbE LAN ports •LCD display •Infrared remote receiver •Proximity sensor Physical dimensions (h x w x d): 259 x 192 x 287.5 mm (10.20 x 7.56 x 11.32 in.) Physical weight: 8.20 kg (18.04 lb) without disks Power consumption: •BTU at full power supply utilization: 172.79W •In operation: 96.15W •Power off (Wake On LAN): 799.89 mW •Power off: 419.62 mW Electrical: •Internal 200W server-rated AC power supply •Input: 100-240 VAC, 50/60 Hz Environmental requirements: •Operating temperature: 0 to 40°C (32°...
Page 154
EDA 500 Technical Specifications The EDA 500 storage system meets the following technical specifications: General: •Five-bay storage •One eSATA port •Proximity sensor Physical dimensions (h x w x d): 259 x 192 x 287.5 mm (10.20 x 7.56 x 11.32 in.) Physical weight: 7.3 kg (16.1 lb) without disks Power consumption: •BTU at full power supply utilization: 88.17W •In operation: 37.3W •Power off: 453.8 mW Electrical: •Internal 200W server-rated AC power supply •Input: 100-240 VAC, 50/60 Hz Environmental...
Page 155
Certifications: FCC Class B, CE Class B, RoHS, VCCI Class B Safety Warnings •The equipment contains no operator access areas and is certified for installation only by trained personnel, according to the installation instructions provided with each storage system. •Install the socket-outlet near the equipment in an easily accessible location. •Observe the on-board battery precautions. Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to their instructions....
Page 156
•Keep the area around the ReadyNAS clean and free of clutter. •See the technical specifications in this manual for details about your specific ReadyNAS storage systems. •Replace the on-board battery only with the same battery or an equivalent type of battery recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. Installing the battery upside down reverses its polarities and creates a danger of explosion. Note •Only trained service technicians can...