Netgear Rn214 4 Bay Desktop Readynas Storage Hardware Manual
Have a look at the manual Netgear Rn214 4 Bay Desktop Readynas Storage Hardware Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 137 Netgear manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Environmental requirements: •Operating temperature: 0 to 40°C (32° to 104°F) •Operating humidity: 20 to 80% relative humidity (noncondensing) •Storage temperature: –20 to 70°C (–4 to 158°F) •Storage humidity: 5 to 95% relative humidity (noncondensing) •Software-controlled 120 mm chassis cooling fan Certifications: FCC Class B, CE Class B, RoHS, VCCI Class B, CCC, MIC, BIS ReadyNAS 626X Technical Specifications The ReadyNAS 626X storage system meets the following technical specifications: General: •Intel Xeon processor D-1521 •8GB ECC DDR4 memory •Six-bay storage •One eSATA port •One USB 3.0 port (front) •Two USB 3.0 ports (back) •Two 1 GbE LAN ports •Two 10 Gbe LAN ports •OLED display Physical dimensions (h x w x d): 260 x 190 x 280 mm (10.24 x 7.48 x 11.02 in.) Physical weight: 7.9 kg (17.4 lb) without disks Defaults and Technical Specifications 151 ReadyNAS OS 6.5
Power consumption: •BTU at full power supply utilization: 100W •In operation: 70.5W •Power off (Wake On LAN): 310 mW •Power off: 264 mW Electrical: •Internal 200W server-rated AC power supply •Input: 100–240 VAC, 50/60 Hz Environmental requirements: •Operating temperature: 0 to 40°C (32° to 104°F) •Operating humidity: 20 to 80% relative humidity (noncondensing) •Storage temperature: –20 to 70°C (–4 to 158°F) •Storage humidity: 5 to 95% relative humidity (noncondensing) •Software-controlled 120 mm chassis cooling fan Certifications: FCC Class B, CE Class B, RoHS, VCCI Class B, CCC, MIC, BIS ReadyNAS 716X Technical Specifications The ReadyNAS 716X storage system meets the following technical specifications: General: •Intel Xeon processor E3-1265L v2 CPU •16 GB ECC memory •Six-bay storage •Three eSATA ports •One HDMI port •One USB 2.0 port (front) •Two USB 3.0 ports (back) •Two 1 GbE LAN ports Defaults and Technical Specifications 152 ReadyNAS OS 6.5
•Two 10 GbE LAN ports •LCD display •Infrared remote receiver •Proximity sensor Physical dimensions (h x w x d): 259 x 192 x 287.5 mm (10.20 x 7.56 x 11.32 in.) Physical weight: 8.20 kg (18.04 lb) without disks Power consumption: •BTU at full power supply utilization: 172.79W •In operation: 96.15W •Power off (Wake On LAN): 799.89 mW •Power off: 419.62 mW Electrical: •Internal 200W server-rated AC power supply •Input: 100-240 VAC, 50/60 Hz Environmental requirements: •Operating temperature: 0 to 40°C (32° to 104°F) •Operating humidity: 20 to 80% relative humidity (noncondensing) •Storage temperature: -20 to 70°C (-4 to 158°F) •Storage humidity: 5 to 95% relative humidity (noncondensing) •Software-controlled 120 mm chassis cooling fan Certifications: FCC Class B, CE Class B, RoHS, VCCI Class B Defaults and Technical Specifications 153 ReadyNAS OS 6.5
EDA 500 Technical Specifications The EDA 500 storage system meets the following technical specifications: General: •Five-bay storage •One eSATA port •Proximity sensor Physical dimensions (h x w x d): 259 x 192 x 287.5 mm (10.20 x 7.56 x 11.32 in.) Physical weight: 7.3 kg (16.1 lb) without disks Power consumption: •BTU at full power supply utilization: 88.17W •In operation: 37.3W •Power off: 453.8 mW Electrical: •Internal 200W server-rated AC power supply •Input: 100-240 VAC, 50/60 Hz Environmental requirements: •Operating temperature: 0 to 40°C (32° to 104°F) •Operating humidity: 20 to 80% relative humidity (noncondensing) •Storage temperature: -20 to 70°C (-4 to 158°F) •Storage humidity: 5 to 95% relative humidity (noncondensing) •Software controlled 120 mm chassis cooling fan Defaults and Technical Specifications 154 ReadyNAS OS 6.5
Certifications: FCC Class B, CE Class B, RoHS, VCCI Class B Safety Warnings •The equipment contains no operator access areas and is certified for installation only by trained personnel, according to the installation instructions provided with each storage system. •Install the socket-outlet near the equipment in an easily accessible location. •Observe the on-board battery precautions. Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to their instructions. Note •Connect the storage systems and their associated LAN connections only to equipment within the same building. Electrical Safety Precautions Follow basic electrical safety precautions to protect yourself from harm and the ReadyNAS from damage: •Be aware of the locations of the power on/off switch on the chassis as well as the rooms emergency power-off switch, disconnection switch, or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system. •Do not work alone when working with high-voltage components. •Always disconnect power from the system when removing or installing main system components, such as the main board or memory modules.When disconnecting power, first power down the system with the operating system and then unplug the power cords of all the power supply storage systems in the system. •When working around exposed electrical circuits, ensure that another person who is familiar with the power-off controls is nearby to switch off the power if necessary. •Use only one hand when working with powered-on electrical equipment.This is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with. •Do not use mats designed to decrease static electrical discharge as protection from electrical shock. Instead, use rubber mats that have been specifically designed as electrical insulators. •Use only power supply cords that include a grounding plug and plug them into grounded electrical outlets. General Safety Precautions Follow these rules to ensure general safety: Defaults and Technical Specifications 155 ReadyNAS OS 6.5
•Keep the area around the ReadyNAS clean and free of clutter. •See the technical specifications in this manual for details about your specific ReadyNAS storage systems. •Replace the on-board battery only with the same battery or an equivalent type of battery recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. Installing the battery upside down reverses its polarities and creates a danger of explosion. Note •Only trained service technicians can replace the soldered-in self-resetting PTC (positive temperature coefficient) fuses on the main board, using only new fuses that are the same as or equivalent to the ones being replaced. Contact technical support for details and support. Electrostatic Discharge Precautions Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards.The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD: •Use a grounded wrist strap designed to prevent static discharge. •Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use. •Touch a grounded metal object before removing the board from the antistatic bag. •Do not let components or PCBs come into contact with your clothing, which might retain a charge even if you are wearing a wrist strap. •Handle a board by its edges only; do not touch its components, peripheral chips, memory modules, or contacts. •When handling chips or modules, avoid touching their pins. •Put the main board and peripherals back into their antistatic bags when not in use. •For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners, and the main board. Defaults and Technical Specifications 156 ReadyNAS OS 6.5