Figure 8. ReadyNAS 202 drive bays 1.Drive bay door 2.Disk tray handle 3.Recessed disk tray handle lock 4.Disk tray release latch 5.Drive bays Rear Panel The following figure shows the rear panel of the ReadyNAS 202. NETGEAR ReadyNAS 202 31 ReadyNAS OS 6.5
Figure 9. ReadyNAS 202 rear panel 1.Exhaust fan 2.Kensington lock 3.USB 3.0 ports 4.eSATA port 5.GbE ports with LED status indicators The two GbE ports are equivalent.They can be used as two separate Ethernet connections, or can be configured as a single, bonded port with a 2 Gbps potential speed. For information on how to configure a bonded port, and the network configuration requirements needed to support 2 Gbps, see the ReadyNAS OS 6 Software Manual, which is available at support.netgear.com/product/ReadyNAS-OS6. Note 6.Reset button 7.Power adapter socket Status Information You can obtain information about the status of your storage system by reviewing the indicators listed in the following table. NETGEAR ReadyNAS 202 32 ReadyNAS OS 6.5
Table 3. ReadyNAS 202 indicator descriptions DescriptionIndicator Press this button to turn on the ReadyNAS.The LED has these states: •On. Powered on. •Blinking. Booting or shutting down. •Off. Powered off. Power button and LED Each drive bay has an LED associated with it on the front panel of the storage system.The disk LEDs have these states: •On. Power is on and the disk is operating normally. •Blinking.The disk was removed, failed, or is resynchronizing. See the display screen for details. •Off.The drive bay is empty. Disk LEDs (1, 2) The disk activity LED has these states: •Blinking. A disk is active. •Off. Disk is idling. Disk activity LED Two LED status indicators are built into each port, one off or green and one showing three states: off, amber, or green.They indicate port speed and activity as follows: •Green, green. 1000 Mbps connection speed, no activity. •Green blinking, green. 1000 Mbps connection speed, activity. •Green, amber. 100 Mbps connection speed, no activity. •Green blinking, amber. 100 Mbps connection speed, activity. •Green on, off. 10 Mbps connection speed, no activity. •Green blinking, off. 10 Mbps connection speed, activity. •Off, off. No connection. Rear panel Ethernet port LEDs Power On and Shut Down This section describes how to power on and shut down your system. If you must shut down the system, use one of the preferred shutdown methods whenever possible. NETGEAR ReadyNAS 202 33 ReadyNAS OS 6.5
Power On To power on the system: 1.Connect the system to a power supply. Depending on the system's last power state, the system might power on automatically. For more information, see Power State on page 34. Note 2.If necessary, press the Power button. The system powers on. Preferred Shutdown You can gracefully shut down your system by using the Power button or the ReadyNAS local admin page. For information about how to gracefully shut down your system using the ReadyNAS local admin page, see the ReadyNAS OS 6 Software Manual, which is available at support.netgear.com/product/ReadyNAS-OS6. To gracefully shut down your system using the Power button: 1.Press the Power button. The Power LED blinks, prompting you to confirm the shutdown. 2.Press the Power button again. The system shuts down gracefully. Forced Shutdown Perform a forced shutdown only if the storage system is not responding. To perform a forced shutdown: •Unplug the system from the power supply. Power State If the power supply is interrupted due to a power failure, the system returns to its last state when the power supply is restored: •If the system was powered on at the time of the power failure, the system powers on when the power supply is restored. •If the system was powered off at the time of the power failure, the system remains off when the power supply is restored. NETGEAR ReadyNAS 202 34 ReadyNAS OS 6.5
Boot Menu Use the boot menu to restart or troubleshoot your ReadyNAS storage system.Your storage system has the following boot modes: •Normal. Initiates a normal boot process, just like booting using the Power button. •Factory default. Initiates a short disk test that takes approximately 5 minutes. After the disk test, a 10-minute time-out period begins. WARNING: The factory default reboot process resets the storage system to factory settings, erases all data, resets all defaults, and reformats the disk to X-RAID. -If you want to cancel the factory default process, power off the storage system before the 10-minute time-out ends.The system powers down safely without causing any data loss. -If you want to reset the system to factory default settings, do not power off your system. After the 10-minute time-out period, the factory default process begins. To start the factory default process immediately, press the Backup button during the 10-minute time-out period. Tip •OS reinstall. Reinstalls the firmware from the internal flash to the disks. Use the OS reinstall boot mode when the system crashes and corrupts some configuration files. OS reinstall boot mode also resets some settings on your storage system, such as Internet protocol settings and the administrator password, to defaults. •Tech support. Boots into a low-level diagnostic mode. Use the tech support boot mode only when a NETGEAR technical support representative instructs you to do so. •Volume read only. Mounts a volume as read-only. Use this option when you are attempting to rescue data off a disk during a disaster recovery. •Memory test. Performs a memory test.The memory test runs for eight hours.The current status and the pass or fail result is reported using the storage system LEDs, as described in the following table: Figure 10. Memory Test Status Backup LEDDisk 2 LEDDisk 1 LEDPower LEDMemory Test State BlinkingOffOffOff1st hour OffBlinkingOffOff2nd hour OffOffBlinkingOff3rd hour BlinkingBlinkingBlinkingOff4th hour BlinkingOffOffOn5th hour NETGEAR ReadyNAS 202 35 ReadyNAS OS 6.5
(Continued) Backup LEDDisk 2 LEDDisk 1 LEDPower LEDMemory Test State OffBlinkingOffOn6th hour OffOffBlinkingOn7th hour BlinkingBlinkingBlinkingOn8th hour BlinkingBlinkingBlinkingBlinkingResult: fail OnOnOnOnResult: pass •Test disk. Performs an offline full disk test.This process can take four hours or more, depending on the size of your disks. Any problems are reported in the system logs. For more information about viewing the system logs, see the ReadyNAS OS 6 Software Manual, which is available at support.netgear.com/product/ReadyNAS-OS6. To access the boot menu: 1.Power off your storage system. 2.Using a straightened paper clip, press and hold the Reset button. 3.Press the Power button. The system powers on. 4.Continue to press the Reset button until the Power LED, USB and backup status LED, disk 1 LED, and disk 2 LED light. 5.Press the Backup button to scroll through boot mode options. The storage system shows the boot mode options using the LEDs, as described in the following table: Status IndicatorBoot Mode USB and Backup LED Disk 2 LED Disk 1 LED Power LED Description All four LEDs light.Boot menu Power LED lights.Normal Disk 1 LED lights.Factory default Disk 2 LED lights.OS reinstall USB and backup status LED lights.Tech support Power LED and disk 1 LED light.Volume read only NETGEAR ReadyNAS 202 36 ReadyNAS OS 6.5
(Continued) Status IndicatorBoot Mode USB and Backup LED Disk 2 LED Disk 1 LED Power LED Description Power LED and disk 2 LED light.Memory test Power LED and USB and backup status LED light. Test disk Legend: •On: •Off: 6.Press and release the Reset button to confirm your boot menu selection. The system boots in the selected boot mode. NETGEAR ReadyNAS 202 37 ReadyNAS OS 6.5
5 NETGEAR ReadyNAS 204 This chapter provides an overview of the physical features of the ReadyNAS 204 and includes the following sections: •Front and Side Panels on page 39 •Drive Bays on page 39 •Rear Panel on page 40 •Status Information on page 41 •Power On and Shut Down on page 42 •Boot Menu on page 44 38
Front and Side Panels The following figure shows the front and side panels of the ReadyNAS 204. Figure 11. ReadyNAS 204 front and side panels 1.Exhaust vents 2.USB 2.0 port 3.Backup button and LED 4.Disk LEDs 5.Disk activity LED 6.Power button and LED 7.Drive bay door 8.Status display screen Drive Bays The following figure shows the drive bays of the ReadyNAS 204. NETGEAR ReadyNAS 204 39 ReadyNAS OS 6.5
Figure 12. ReadyNAS 204 drive bays 1.Drive bay door 2.Disk tray handle 3.Recessed disk tray handle lock 4.Disk tray release latch 5.Drive bays Rear Panel The following figure shows the rear panel of the ReadyNAS 204. NETGEAR ReadyNAS 204 40 ReadyNAS OS 6.5