NDA-24232 Issue 2.0Page 3-1 VisuaLink 128/384 Quick Installation Guide Chapter 3 Chapter 3 Startup Screen for the VisuaLink 128 and VisuaLink 384 When you first turn on your VisuaLink, there will be an initial configuration screen. These configuration screens will have to be completed before your system becomes operational. 3.1 Start up configuration screensThe following are the startup screens that will be active on first power up or acti- vated on demand by the user after choosing the Environmental initialize. Welcome Screen: This is a welcome screen for the User. Vi s u a L i n k Thank you for purchasing one of the most simple and portable video conferencing systems available. We will now show you how to set up your system. This will only have to be done once. NOTE: If remote controller doesn’t work, make sure the switch setting of D30 camera IR out is ON. Switch is located on the bottom of the camera. Click here to continue Configure laters Note is yellow
![](/img/blank.gif)
Page 3-2NDA-24232 Issue 2.0 Chapter 3 VisuaLink 128/384 Quick Installation Guide Remote Controller Directions: Gives some general directions for configure the VisuaLink system. Using the Remote controller highlight the NEXT option to advance to the configure screen or press the lower portion of the CAMERA CONTROL key to highlight the Configure Later to advance to the normal ICON screens. If you choose to configure later, the system will have to be programmed with My numbers and SPID’s in order to work correctly. 3.2 Setting Up your ISDN Line InformationThe following is a description of BRI Line setup Part 1- Remote Controller Location - Locate the CAMERA control. The CAMERA control key is the BLUE round key. Use this key to move the Cursor up/down and Left/Right in the Configuration Screens. - Locate the ENTER key on the Wireless remote controller. Use the ENTER key to confirm selections and store information. Next screen Prior screen s Part 2- Setting up Your ISDN Line Introduction: When ordering BRI service, you will usually get 2 My numbers and 2 SPID numbers per BRI. A SPID normally consists of the user’s 3 digit area code, 7 digit ISDN telephone number, followed by a 0101. Ex: MY Number 1: 9727195854 SPID 1: 97271958540101 Note: The VisuaLink 128 requires 2 My numbers and 2 SPID #, while the VisuaLink 384 requires 6 My numbers and 6 SPID #. Next screen Prior screen s Note is yellow
![](/img/blank.gif)
NDA-24232 Issue 2.0Page 3-3 VisuaLink 128/384 Quick Installation Guide Chapter 3 Video Number 1 Screen’s Using the number pad of the wireless remote enter My Number with area code and SPID numbers associated to Line (BRI 1). Each BRI will have My numbers labeled #1 and #2 and two SPID’s. All four numbers must be entered. Choose NEXT when complete. Note: “PROCEED TO STEP 2” will only be shown on the VisuaLink 128 system. VisuaLink 384 will show “Proceed to Line 2 Setup” Step 1--Enter My Number and SPID for BRI LINE 1 My Number 1: [] SPID 1: [ ] My Number 2: [ ] SPID 2: [ ] Next screen Prior screen Press ENTER after choosing each item s Step 1--Enter My Number and SPID for BRI LINE 1 My Number 1: [9727195854] SPID 1: [97271958540101] My Number 2: [9727195855] SPID 2: [97271958550101 ] Next screen Prior screen Press ENTER after choosing each item s
![](/img/blank.gif)
Page 3-4NDA-24232 Issue 2.0 Chapter 3 VisuaLink 128/384 Quick Installation Guide Video Number 2 Screens: Using the number pad of the wireless remote enter My Number with area code and SPID numbers associated to Line (BRI 2). Each BRI will have My numbers labeled #1 and #2 and two SPID’s. All four numbers must be entered. Choose NEXT when complete. Note: This screen will only appear on the VL 384 system. Step 1--Enter My Number and SPID for BRI LINE 2 My Number 1: [] SPID 1: [ ] My Number 2: [ ] SPID 2: [ ] Next screen Prior screen Press ENTER after choosing each item s
![](/img/blank.gif)
NDA-24232 Issue 2.0Page 3-5 VisuaLink 128/384 Quick Installation Guide Chapter 3 Video Number 3 Screens: Using the number pad of the wireless remote enter My Number with area code and SPID numbers associated to Line (BRI 3). Each BRI will have My numbers labeled #1 and #2 and two SPID’s. All four numbers must be entered. Choose NEXT when complete. Note: This screen will only appear on the VL 384 system. 3.3 Optional User Settings:The following is a description for Optional Setting screen. Step 1--Enter My Number and SPID for BRI LINE 3 My Number 1: [] SPID 1: [ ] My Number 2: [ ] SPID 2: [ ] Next screen Prior screen Press ENTER after choosing each item s Part 3 - Optional User Settings Introduction: Site Name: Name identification for your location. Name is displayed on far-end monitor when site is viewed. Password: Required to gain access to the VisuaLink configuration screens. Time display: Sets the internal clock for the Vi s u a L i n k . Next screen Prior screen s
![](/img/blank.gif)
Page 3-6NDA-24232 Issue 2.0 Chapter 3 VisuaLink 128/384 Quick Installation Guide Optional information: You may enter this optional information. The name you enter makes it easy for users to identify this particular VisuaLink. The name can be up to 20 characters long. The Password is the password needed to be entered when selecting the Utilities ICON. After entering the optional information select the NEXT to advance to the next screen. Application Screen’s Using the number pad on the wireless remote controller select the application which the VisuaLink is installed. Your answer to this question will automatically configure the internal parameters for the following: Step 1- Optional User Settings Your Site Name [ ] Password [ ] Time Setting [12/1/1998 10:50] Time Display: Auto Power Save: Next screen Prior screen Press ENTER after choosing each items Item Rollabout/Other Data Conference Gateway Desktop Serial Port 1 Camera EVI-D30 T.120 Camera Camera Serial Port 2 Console Console Console Console Audio Mode G.722 G.728 G.722 G.722 MLP 4.0 24.0 4.0 4.0 Answer Mode Auto Auto Auto Manual LSD 1.2 Off 1.2 1.2 Ext. Remote Auto Off Off Off H.263 Off Off Off Off Lip Sync On On On On
![](/img/blank.gif)
NDA-24232 Issue 2.0Page 3-7 VisuaLink 128/384 Quick Installation Guide Chapter 3 Congratulations Screen The VisuaLink is now setup for the configuration you have entered. Press the ENTER button on the REMOTE CONTROLLER, the VisuaLink will display a blue screen and recycle. The VisuaLink should will power up to a normal state. You may begin to use the video conferencing system immediately. Note: If there are no My Numbers entered in the configuration the VisuaLink will display the Start Up screens. Step 2—Optional User Settings Key in the number of one of the following applications. Applications: 1. Rollabout/Other 2. Data Conference 3. Gateway 4. Desktop Press CANCEL to page back Congratulations, you have just finished setting up your VisuaLink system. For VisuaLink software updates and general VisuaLink knowledge, visit the NEC Knowledge base web site at : http://www.cng.nec.com or http://www.ilibrary.com/phoenix/ntachome.nsf /homepagenav?opennavigator - You may begin to use the video conferencing system immediately. - Press ENTER to activate your configuration. Press CANCEL to page back
![](/img/blank.gif)
Page 3-8NDA-24232 Issue 2.0 Chapter 3 VisuaLink 128/384 Quick Installation Guide VisuaLink system start up screen. Changing the configuration It is important that the CODEC is set up with a local number and SPID numbers. If the unit is not setup with a local number (my number) and SPID, the unit will not allow for dialing and receiving of video calls. If you have entered these numbers in the Start Up configuration, you may ignore this section. If the VisuaLink environment has changed, such as the phone number have changed, you must reconfigure the numbers in the VisuaLink. America, Inc. VisuaLink Powering Up Ver .22.02.37
![](/img/blank.gif)
NDA-24232 Revision 1.0Page 4-1 VisuaLink 128/384 Quick Installation Guide Chapter 4 Chapter 4 Rollabout 128/384 Procedures 4.1 Rollabout System ConnectionsUse the following procedures to set up the VisuaLink 128 or VisuaLink 384. See Appendix A for system drawings for the VisuaLink 128. See Appendix B for the system drawings for the VisuaLink 384. Note: This guide provides connection diagrams for manufacturer-specific components. If your system contains components from other manufacturers, please consult their documentation. Figure 4-1: Equipment Placement 12 VIDEO INS-VIDEO VIDEO AUDIOL MONO RAUDIO OUT (VAR/FIX) 12 VIDEO IN S-VIDEO VIDEO AUDIOL MONO RAUDIO OUT (VAR/FIX) + + ++ +DC IN 5V+ - Serial1 Serial2/RMT O U T I N VIDEO2 VIDEO1 AUDIO ++TEL S/T LINEMI C1 MIC2 MIC3 AUDIO VIDEO S VIDEOIN VISCA OUT POWER OFF ONDC IN 13.5 V+ -MICCAMERA NO.1 2 3 CAMERA REAR MONITOR REAR VisuaLink 128 REAR NT1 REAR VHF/UHF S/T S/TL-BK LINE PWR DIN INTERFACE 1234 5ONPOWER U NT1 FRONT + + ++ +DC IN 5V+ - Serial1 Serial2/RMT O U T I N VID EO2 V IDEO1 A UDIO ++TEL S/T LIN E 1 S /T LINE 2 S/T LINE 3MIC1 MIC2 MIC 3 VisuaLink 384 REAR Note: Connector location on the monitor may vary.Note: Labeling for the connector may vary. Control, Video, & Audio Hole Power Cable Hole
![](/img/blank.gif)
Page 4-2NDA-24232 Revision 1.0 Chapter 4 VisuaLink 128/384 Quick Installation Guide 4.2 Step-by-Step ProcedureThe following are the steps and procedures for the installation of the VisuaLink 128/384. STEP ACTION DRAWING 1. Locate and unpack the Cabinet box. 2. Locate Power Strip at bottom-left (looking through the front) of cabinet and feed power cable through the power opening at rear of cabinet. 3. Plug power strip power cable into AC outlet. Make sure the ON/OFF switch on the upper right outside of the cabinet is in the OFF position. Note: The power switch will be lit when the power strip is in the ON position. Powerstr ip Power Switch