NEAX2400 IPX ISDN Features and Specifications
Page 86NDA-24311, Issue 1
M-73 Music On Hold - PRI
M-73  Music On Hold - PRI
General Description
This feature allows a party to hear music while in the CALL HOLD [C-6], CALL TRANSFER - ATTENDANT [C-
10], CALL TRANSFER - ALL CALLS [C-11], or ATTENDANT CAMP-ON [A-1] conditions.
Operating Procedure
No manual operation is required since this is a software controlled feature.
Service Conditions
1. The system is capable of supplying two switch-selectable music...

Page 102

NEAX2400 IPX ISDN Features and Specifications
NDA-24311, Issue 1
Page 87
Modem Pooling - PRI M-74
M-74 Modem Pooling - PRI
General Description
The MODEM POOLING - PRI feature allows any asynchronous or synchronous data station (DTE) connected to a
Dterm Data Adapter or Data Module to have access to off-premise devices (other terminals, mainframes, personal
computers, etc.) using Modem Pools. Also, off-premise devices can gain access to the Data Modules or Data
Adapters through incoming Modem Pools. Modem...

Page 103

NEAX2400 IPX ISDN Features and Specifications
Page 88NDA-24311, Issue 1
M-74 Modem Pooling - PRI
Operating Procedure (cont’d)
5. After the called modem and the pooled modem exchange carrier signals, the display shows:
6. Data communication can begin.
To release from data communication using a Dterm/Data Adapter (keypad dialing)
1. Press the DATA key to disconnect.
2. The display shows RELEASE D XXXX, indicating that data communication has been released.
Incoming Modem Pooling
To receive a data call from...

Page 104

NEAX2400 IPX ISDN Features and Specifications
NDA-24311, Issue 1
Page 89
Modem Pooling - PRI M-74
Service Conditions
1. Up to eight Modem Pool Groups can be assigned: eight bothway, four incoming, four outgoing, or any
combination thereof.
2. One modem in the group is selected by the DTE at the time of connection.
3. LEAST CALL ROUTING - 3/6-DIGIT [L-6] can be used for optimization of long distance data calls.
4. Incoming MODEM POOLING capabilities are also provided via DIT, DID, or the Attendant.
5....

Page 105

NEAX2400 IPX ISDN Features and Specifications
Page 90NDA-24311, Issue 1
M-75 Multiple Call Forwarding - All Calls - PRI
M-75  Multiple Call Forwarding - All Calls - PRI
General Description
This feature permits a call from the ISDN network to a station set to CALL FORWARDING - ALL CALLS - PRI
[C-95] to be forwarded multiple times to a predesignated idle station.
Operating Procedure
To set CALL FORWARDING - ALL CALLS - PRI [C-95] from an individual station
1. Lift the handset; receive dial tone.
2. Dial...

Page 106

NEAX2400 IPX ISDN Features and Specifications
NDA-24311, Issue 1
Page 91
Multiple Call Forwarding - All Calls - PRI M-75
Service Conditions (cont’d)
7. If the destination station is busy, the calling station may activate CALL BACK [C-1], CALL WAITING
- ORIGINATING [C-31], or EXECUTIVE RIGHT-OF-WAY [E-1] to the destination station.
8. When MULTIPLE CALL FORWARDING - ALL CALLS occurs, the display of the calling party’s D
term
shows the called telephone number and terminating telephone number. The display...

Page 107

NEAX2400 IPX ISDN Features and Specifications
Page 92NDA-24311, Issue 1
N-20 Night Connection - Fixed - PRI
N-20  Night Connection - Fixed - PRI
General Description
This feature routes ISDN calls normally directed to the ATTENDANT CONSOLE [A-3] to a preselected common
station within the system when the Night mode has been entered.
Operating Procedure
To answer NIGHT CONNECTION - FIXED - PRI calls
1. Incoming calls to the ATTENDANT CONSOLE [A-3] in the Night mode are automatically transferred to
a...

Page 108

NEAX2400 IPX ISDN Features and Specifications
NDA-24311, Issue 1
Page 93
Night Connection - Fixed - PRI N-20
Service Conditions (cont’d)
11. A fully restricted station cannot be assigned as a Night station.
12. Incoming Restricted Line: When NIGHT CONNECTION - FIXED - PRI or FLEXIBLE - PRI [N-21] is
active, the line Class of Service restrictions can be automatically changed when the system is in the Night
mode of operation. This allows a station normally restricted during the day to receive incoming...

Page 109

NEAX2400 IPX ISDN Features and Specifications
Page 94NDA-24311, Issue 1
N-21 Night Connection - Flexible - PRI
N-21  Night Connection - Flexible - PRI
General Description
This feature provides arrangements to route ISDN calls normally directed to the ATTENDANT CONSOLE [A-3]
to a preselected station, on a flexibly assignable basis within the system, when the Night mode has been entered.
Operating Procedure
Answering operation is the same as that for NIGHT CONNECTION - FIXED - PRI [N-20].
Each evening,...

Page 110

NEAX2400 IPX ISDN Features and Specifications
NDA-24311, Issue 1
Page 95
Non-Delay Operation - PRI N-22
N-22 Non-Delay Operation - PRI
General Description
This feature allows the ATTENDANT CONSOLE [A-3] to place any calling party on hold, dial the call, and connect
the calling and called parties.
Operating Procedure
1. The Attendant answers an operator call by pressing the ANSWER, or ATND key.
2. Press the START key.
3. Dial the exchange network access code.
4. Dial the desired telephone number.
5. Press...