Home > NEC > Communications System > NEC Neax 2000 Ivs2 Office Data Programming Manual

NEC Neax 2000 Ivs2 Office Data Programming Manual

Here you can view all the pages of manual NEC Neax 2000 Ivs2 Office Data Programming Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 411

 NEAX2000 IVS2 Office Data Programming ManualPage 398  ND-70931 (E), Issue 2.0
NOTE:If space is insufficient, use copies.
CM97 CM97
DSS CONSOLE 
NUMBER
(2 DIGITS)DSS KEY 
NUMBER
(2 DIGITS)SETTING DATA
 (1-8 DIGITS)DSS CONSOLE 
NUMBER
(2 DIGITS)DSS KEY 
NUMBER
(2 DIGITS)SETTING DATA
 (1-8 DIGITS)
00 30
01 31
02 32
03 33
04 34
05 35
06 36
07 37
08 38
09 39
10 40
11 41
12 42
13 43
14 44
15 45
16 46
17 47
18 48
19 49
20 50
21 51
22 52
23 53
24 54
25 55
26 56
27 57
28 58
29 59
STEXE ++ ++
97DESETTING DATA DSS...

Page 412

NEAX2000 IVS2 Office Data Programming Manual    
ND-70931 (E), Issue 2.0   Page 399
CM98 Y=0
ADD-ON
MODULE 
NUMBERMY LINE NUMBER
(1-8 DIGITS)ADD-ON
MODULE 
NUMBERMY LINE NUMBER
(1-8 DIGITS)
00 16
01 17
02 18
03 19
04 20
05 21
06 22
07 23
08 24
09 25
10 26
11 27
12 28
13 29
14 30
15 31
STEXE ++ ++ 980DEMY LINE ADD-ON 
+DE
COMMAND 98:+
 MODULE No.
(00-31) (1-8 digits)No.CM98 

Page 413

 NEAX2000 IVS2 Office Data Programming ManualPage 400  ND-70931 (E), Issue 2.0
NOTE:If space is insufficient, use copies.
CM9A
SOFT KEY No.STATUS No. (00-15) =
SOFT KEY No.STATUS No. (00-15) =
YY=00 YY=10 YY=00 YY=10
1st display 00 1st display 00
01 01
02 02
03 03
2nd display 04 2nd display 04
05 05
06 06
07 07
3rd display 08 3rd display 08
09 09
10 10
11 11
4th display 12 4th display 12
13 13
14 14
15 15
STATUS
STEXE ++ +
9AYYDATA
(2-12 digits) +DE+
+DE COMMAND 9A:SOFT KEY
+
No.No.
(4 digits) CM9A 

Page 414

NEAX2000 IVS2 Office Data Programming Manual    
ND-70931 (E), Issue 2.0   Page 401
NOTE:If space is insufficient, use copies.
CM9A
SOFT KEY No.STATUS No. (00-15) =
SOFT KEY No.STATUS No. (00-15) =
YY=01 YY=11 YY=01 YY=11
1st display 00 1st display 00
01 01
02 02
03 03
2nd display 04 2nd display 04
05 05
06 06
07 07
3rd display 08 3rd display 08
09 09
10 10
11 11
4th display 12 4th display 12
13 13
14 14
15 15
STATUS
STEXE ++ +
9AYYDATA
(2-12 digits) +DE+
+DE COMMAND 9A:SOFT KEY
+
No.No.
(4 digits)CM9A 

Page 415

 NEAX2000 IVS2 Office Data Programming ManualPage 402  ND-70931 (E), Issue 2.0
NOTE:If space is insufficient, use copies.
CM9A
SOFT KEY No.STATUS No. (00-15) =
SOFT KEY No.STATUS No. (00-15) =
YY=02 YY=12 YY=02 YY=12
1st display 00 1st display 00
01 01
02 02
03 03
2nd display 04 2nd display 04
05 05
06 06
07 07
3rd display 08 3rd display 08
09 09
10 10
11 11
4th display 12 4th display 12
13 13
14 14
15 15
STATUS
STEXE ++ +
9AYYDATA
(2-12 digits) +DE+
+DE COMMAND 9A:SOFT KEY
+
No.No.
(4 digits) CM9A 

Page 416

NEAX2000 IVS2 Office Data Programming Manual    
ND-70931 (E), Issue 2.0   Page 403
NOTE:If space is insufficient, use copies.
NOTE:CM9A YY=03, YY=13 (Pattern No.3) is default Soft Key setting. 
Refer to the Command Manual.
CM9A
SOFT KEY No.STATUS No. (00-15) =
SOFT KEY No.STATUS No. (00-15) =
YY=03 YY=13 YY=03 YY=13
1st display 00 1st display 00
01 01
02 02
03 03
2nd display 04 2nd display 04
05 05
06 06
07 07
3rd display 08 3rd display 08
09 09
10 10
11 11
4th display 12 4th display 12
13 13
14 14
15...

Page 417

 NEAX2000 IVS2 Office Data Programming ManualPage 404  ND-70931 (E), Issue 2.0
NOTE:If space is insufficient, use copies.
 : Initial Data
CM1A CMA0CMA1
MY LINE
NUMBERDATA
STATION
NUMBERTYPE
OF
DATA
ADAPTERYY
04 05 06 07 08 09 11 12 13 14 19 21
04/15 0/1 0/1 0/1 0/1 0/1 0/100/
04/
15
15 31 1 7 1 1 15 1 1 3 15 1 15
 
INITIALINITIAL
00~310~3/700~07/151~301~15
STEXE ++ ++
1ADEDATA STATION
COMMAND 1A:No.
(1-8 digits) + MY LINE
No.
(1-8 digits)DE
+
STEXE ++ +A0DESETTING DATA
COMMAND A0:
(2 digits) + DATA...

Page 418

NEAX2000 IVS2 Office Data Programming Manual    
ND-70931 (E), Issue 2.0   Page 405
NOTE:If space is insufficient, use copies.
CMA5 CMA5
YY
(00-99/
000-199)STATION
NUMBER (A)
/TRUNK NUMBER 
(A)STATION
NUMBER (B)
/TRUNK NUMBER 
(B)YY
(00-99/
000-199)STATION
NUMBER (A)
/TRUNK NUMBER 
(A) STATION
NUMBER (B)
/TRUNK NUMBER 
(B)
STEXE +++ + A5YY/DETRUNKDE COMMAND A5:
+ +
No. (A) DATA/ISDN LINE
STATION No.(A)
TRUNK
No. (B) DATA/ISDN LINE
STATION No.(B)
(1-10 digits) (4 digits) (1-10 digits) (4 digits)
YYYCMA5 

Page 419

 NEAX2000 IVS2 Office Data Programming ManualPage 406  ND-70931 (E), Issue 2.0
 Attribute Data for RS-232C Port:
:  Initial Data
CMA6
YY
04 05 06 07 08 09 10 11 12 20 21 22 24
0-6 0/1 0/3/7 0/1 0/1 00-15 0/1 0/1 0/1 2/7 0-2 0/1/3 1-7
NONE1711150117NONE37
STEXE ++ ++
A6YYDESETTING DATA
3DE
COMMAND A6:+ +
(1-3 digits) CMA6 

Page 420

NEAX2000 IVS2 Office Data Programming Manual    
ND-70931 (E), Issue 2.0   Page 407
:  Initial Data
CCH 
No.
CMA7
YY
00 01 02 03 04 05 06 07 10 26 28
000
25500001 
1636700001 
163670~300001 
1636700001 
163670000
99990000
999900
150/1 0/1
NONE NONE NONE 3 NONE NONE NONE NONE 15 1 1
0
1
2
3
4
5
6
7
:  Initial Data
CCH 
No.
CMA7
YY
40 41 42 43 44
000 000 000 000 000 000 000 000 000 000 000 000 000 000 000 000
0~7/15
255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255
15
0
1
2
3
4
5
6
7
~
~
~
~...
Start reading NEC Neax 2000 Ivs2 Office Data Programming Manual

Related Manuals for NEC Neax 2000 Ivs2 Office Data Programming Manual

All NEC manuals