Home > NEC > Communications System > NEC Neax 2000 Ivs2 Isdn Features And Specifications

NEC Neax 2000 Ivs2 Isdn Features And Specifications

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs2 Isdn Features And Specifications online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ISDN TERMINAL
    NEAX2000 IVS2ISDN Features and SpecificationsPage 12NDA-24273, Issue 1.0
    12. In case of Point to Multipoint connection, a Single Line Telephone/Multiline Terminal must dial ISDN
    Multipoint station number assigned by CM1B, not the ISDN Terminal number assigned by CM10.
    13. When a Multiline Terminal calls an ISDN Terminal or an ISDN Terminal calls a Multiline Terminal, a
    calling station number is displayed to the calling Multiline Terminal or the ISDN Terminal.
    In case of Point to Multipointconnection, the calling station numberdisplayed is the ISDN station number
    assigned by CM10.
    14. Station to Station Calling between a PS station and an ISDN Terminal isavailable.
    15. Only Preset Dialing can be used from an ISDN Terminal, Overlap dialing is not available.
    16. For Event Based CCIS you must have 64K unrestricted digital data connections (circuit mode). The
    Telephone company cannot overflow these ISDN calls to analog lines. 
    						
    							MEGACOM® ACCESS/WATS
    NEAX2000 IVS2ISDN Features and Specifications
    NDA-24273, Issue 1.0Page 13
    MEGACOM®ACCESS/WATS
    General Description
    AT&T’s MEGACOM®(WATS) network, as well as WATS from other carriers, can be used.
    Operating Procedure
    No manual operation is required.
    Service Conditions
    1. The available WATS service is limited to Maximal Subscribed WATS Band (MSB).
    2. No specific band will be indicated to the Network.
    NEAX2000 IVS2
    PRIISDN
    NETWORKMEGACOM/WATS 
    						
    							MEGACOM® 800 SERVICE/800 WATS ULTRA WATS
    NEAX2000 IVS2ISDN Features and SpecificationsPage 14NDA-24273, Issue 1.0
    MEGACOM®800 SERVICE/800 WATS ULTRA WATS
    General Description
    AT&T’s MEGACOM®800 (Inward WATS) network, as well as 800 WATS provided by other carriers, can be
    used.
    Operating Procedure
    No manual operation is required.
    Service Conditions
    1. CM76 can be used to convert indialed digits.
    2. The Dialed Number Identification Service (DNIS) must match the station numbering plan (CM20).
    3. Multiple DNISs are supported.
    NEAX2000 IVS2
    PRIISDN
    NETWORKMEGACOM/
    800 WATS
    ULTRA WATS
    MEGACOM 800
    800 WATS
    ULTRA WATS 
    						
    							MULTIQUEST®/900 SERVICE
    NEAX2000 IVS2ISDN Features and Specifications
    NDA-24273, Issue 1.0Page 15
    MULTIQUEST®/900 SERVICE
    General Description
    AT&T’s MultiQuest®service can be used. (It is a “900”-type service.) Also, 900 service provided by other
    carriers can be used.
    Operating Procedure
    No manual operation is required.
    Service Conditions
    1. The Dialed Number Identification Service (DNIS) must match the numbering plan (CM20) of the
    NEAX2000 IVS2.
    2. Multiple DNIS numbers are supported.
    3. Command CM76 can be used to convert DNIS digitsreceived from the ISDN Network.
    PRIISDN
    NETWORKMultiGuest/
    900 Service
    NEAX2000 IVS
    2 
    						
    							SUBADDRESS–PRESENT
    NEAX2000 IVS2ISDN Features and SpecificationsPage 16NDA-24273, Issue 1.0
    SUBADDRESS–PRESENT
    General Description
    This feature allows a primary rate interface ISDN trunk to transfer the called party subaddress information to a
    destination ISDN station when the call is originated by the NEAX2000 IVS2. Dialing the called party station
    number and subaddress is required.
    Operating Procedure
    The callingstation dials the ISDN subscriber number (including access code) followed by an asterisk (*),then
    dials the called party subaddress followed by a pound sign(#). ISDNautomatically recognizes the subaddress
    and transfers the information to the destination party.
    Service Conditions
    1. If the calling party fails to dial the called party subaddress, ISDN cannot transfer any called party subaddress
    informationtothedestinationparty.
    2. If a calling party does not wish to provide a called party subaddress, the call must terminate with a pound
    sign (#) (Immediate Start). If a pound sign is not entered, a Timing Start operation begins. The Timing Start
    uses the interdigit time-out operation.
    3. Subaddress dialing is available only on those telephone terminals that can generate push-button (DTMF)
    signals.
    4. The called party subaddress must not exceed eight digits.
    5. The called party subaddress can be sent with trunk direct dial access.
    6. This feature may cannot be used when a call is originated to ISDN using Speed Calling or Call Forwarding
    features.
    ISDN DTI PBX
    555-5000
    CALLING PARTY4211
    SUBADDRESS
    DIAL
    214-555-
    5000
    4211 
    						
    							TRUNK PROVISIONING SERVICE SELECTION
    NEAX2000 IVS2ISDN Features and Specifications
    NDA-24273, Issue 1.0Page 17
    TRUNK PROVISIONING SERVICE SELECTION
    General Description
    Each channel of a PRI interface can be dedicated to a particular service. Services are designated to specific
    channels; once designated, a channel can be used only for that service.
    Operating Procedure
    No manual operation is required.
    Service Conditions
     The services that can be designated include MEGACOM®/WATS and MEGACOM®800/800WATS.
     Arrangement with the carrier at the time of provisioning is needed.
    B-channels
    D-channelPRI
    Service A
    Service B 
    						
    							NEAX2000 IVS2ISDN Features and SpecificationsPage 18NDA-24273, Issue 1.0
    This page is for your notes. 
    						
    							APPENDIX A: DtermFIXED FUNCTION KEYS
    NEAX2000 IVS2ISDN Features and Specifications
    NDA-24273, Issue 1.0Page 19
    APPENDIX A: DtermFIXED FUNCTION KEYS
    Series E Series III Description
    Answer ANS To answer a waiting call
    Conf CNF To establish three-way conversation
    Feature FNCTo activate terminal setup functions and to program One-Touch
    Speed Dial/Feature Keys
    Hold HOLD To place an internal or external call on hold
    Recall LNR/SPD To terminate established call and re-seize internal dial tone
    Redial RECALL To active Last Number Call and Speed Calling
    Speaker SPKRTo control the built-in speaker which can be used for Hands Free
    dialing/monitoring
    Transfer TRFTo transfer established calls to another station, without attendant
    assistance 
    						
    							APPENDIX B: DtermLCD DISPLAYS
    NEAX2000 IVS2ISDN Features and SpecificationsPage 20NDA-24273, Issue 1.0
    APPENDIX B: DtermLCD DISPLAYS
    Description Series E Series III
    Clock/Calendar Display 10:06 PM MON 21 APR 1999 10:06 PM TUE 14
    Busy BUSY XXXX BUSY XXXX
    Restriction RESTRICT XXXX RST XXXX
    Do Not Disturb DND XXXX DND XXXX
    Call Forwarding - All Calls CF ALL XXXX FDA XXXX
    Call Forwarding - Busy Line CF BUSY XXXX FDB XXXX
    Call Forwarding - No Answer CF NANS XXXX FDN XXXX
    Call Transfer TRANSFER XXXX XFR XXXX
    Conference CONF XXXX XXXX CNF XXXX XXXX
    Non Exclusive Hold HOLD XXXX HLD XXXX
    Exclusive Hold E-HOLD XXXX EHD XXXX
    Stack DialREDIAL[*/#]/SPEED -1
    82625563RDL[*/#]/SPD -1
    82625563 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Isdn Features And Specifications