Page 111

CHAPTER 3 ND-45503 (E)
Pag e 1 00
Revision 2.0CM59
FUNCTION No.SETTING
DATA
00
:  Initial Data
CM60
AT T
NUMBER
YY
00
(GROUP No.)01
(MASTER)02
(A0)04
(A2)06
(A4)15
(F5)16
(F6)17
(F7)2226
(BLF)27
(TONE RING)30
0-3 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 00-99 0-3 X-X...X
0
1
2
3
4
5
6
7
1 1111111 3 NONE
SETTING DATASTEXE ++ + ++
59DE
FUNCTION No. (00)+DE
COMMAND 59:
 (2 digits) (2 digits)
MAT
STEXE ++ + ++ 60YYDE
SETTING DATA ATT NUMBER +DE
COMMAND 60:
(0-7) (1-8 digits) 

Page 112

ND-45503 (E) CHAPTER 3
Pag e 1 01
Revision 2.0 Note:If space is insufficient, use copies
CM5A YY=00
BLOCK No. VIRTUAL TRUNK No. + , + VIRTUAL STATION No.
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
SETTING DATA
(6-9 digits) (3 digits)STEXE ++
+
5AYY+DE
+ +DE
COMMAND 5A:BLOCK No. 

Page 113

CHAPTER 3 ND-45503 (E)
Pag e 1 02
Revision 2.0:  Initial Data
CM61
KEY
NUMBERYY
00(TN) 01(A0) 03(A2) 05(A4) 06(A5) 30
00-63 0/1 0/1 0/1 0/1 00
1111
MAT
STEXE ++ + ++ 61YYDE
SETTING DATA KEY NUMBER +DE
COMMAND 61:
(3 digits) (1-3 digits) 

Page 114

ND-45503 (E) CHAPTER 3
Pag e 1 03
Revision 2.0 :  Initial Data
CM62 CM62
TENANT 
NUMBERY
TENANT 
NUMBERY
0123 0123
00 32
01 33
02 34
03 35
04 36
05 37
06 38
07 39
08 40
09 41
10 42
11 43
12 44
13 45
14 46
15 47
16 48
17 49
18 50
19 51
20 52
21 53
22 54
23 55
24 56
25 57
26 58
27 59
28 60
29 61
30 62
31 63
1111 1111
INITIALINITIAL
STEXE ++ ++ 62YDE
SETTING DATA TENANT NUMBER +DE
COMMAND 62:+
(2 digits) (1 digit) 

Page 115

CHAPTER 3 ND-45503 (E)
Pag e 1 04
Revision 2.0
•Y = 0
:  Initial Data
CM63
Y TENANT ATENANT B
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
000
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
11111111111111111111
STEXE ++ ++ 630DE
SETTING DATA TENANT A +DE
COMMAND 63:+ + TENANT B
(2 digits) (2 digits) (1 digit) 

Page 116

ND-45503 (E) CHAPTER 3
Pag e 1 05
Revision 2.0
•Y = 1
:  Initial Data
CM63
Y TENANT ATENANT B
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
100
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
11111111111111111111
STEXE ++ ++ 631DE
SETTING DATA TENANT A +DE
COMMAND 63:+ + TENANT B
(2 digits) (2 digits) (1 digit) 

Page 117

CHAPTER 3 ND-45503 (E)
Pag e 1 06
Revision 2.0
•Y = 2
:  Initial Data
CM63
Y TENANT ATENANT B
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
200
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
11111111111111111111
STEXE ++ ++ 632DE
SETTING DATA TENANT A +DE
COMMAND 63:+ + TENANT B
(2 digits) (2 digits) (1 digit) 

Page 118

ND-45503 (E) CHAPTER 3
Pag e 1 07
Revision 2.0 Note:If space is insufficient, use copies.
:  Initial Data
CM63
Y TENANT ATENANT B
11111111111111111111
STEXE ++ ++ 63YDE
SETTING DATA TENANT A +DE
COMMAND 63:+ + TENANT B
(2 digits) (2 digits) (1 digit) 

Page 119

CHAPTER 3 ND-45503 (E)
Page 108 Addendum-002
Revision 2.2 JANUARY, 1999CM64
TENANT
No.Y=0 Y=1 Y=2
SETTING 
DATA
(00~03)SETTING 
DATA
(00~09)SETTING 
DATA
(00~03)
STEXE ++ ++ 64YDEDE
COMMAND 64:+ + TENANT No.
(2 digits)SETTING DATA
(2 digits) 

Page 120

ND-45503 (E) CHAPTER 3
Addendum-002 Page 108-1
JANUARY, 1999 Revision 2.2CM65
TENANT
No.SETTING DATA
YY=23
(0/1)YY=24
(0/1)YY=25
(0/1)YY=26
(0/1)YY=27
(0/1)YY=28
(0/1)YY=30
(0/1)YY=50
(0/1)YY=51
(0/1)
COMMAND 65:STEXE ++
+ +
65YYDEDE + + TENANT No.
(2 digits)SETTING DATA
(1 digit) 