Home > NEC > Monitor > NEC Multisync Lcd2690wuxi2 Users Manual

NEC Multisync Lcd2690wuxi2 Users Manual

Here you can view all the pages of manual NEC Multisync Lcd2690wuxi2 Users Manual. The NEC manuals for Monitor are available online for free. You can easily download all the documents as PDF.

Page 11

English
English-9
Brightness/Contrast Controls
BRIGHTNESS
Adjusts the overall image and background screen brightness.
NOTE:When  PROGRAMMBLE is set by PICTURE MODE (Page 26), you cannot select BRIGHTNESS.
CONTRAST
Adjusts the image brightness in relation to the background.
AUTO CONTRAST (Analog input only)
Adjusts the image displayed for non-standard video inputs.
ECO MODE
Decreases the amount of power consumed by reducing the brightness level.
1: Decreases the brightness by 25%.
2: Decreases the...

Page 12

English-10
FINE (Analog input only)
Improves focus, clarity and image stability by increasing or decreasing this setting.
If the “Auto Adjust function” and the “H.Size” function do not give you a satisfactory picture setting, a fine tuning can
be performed using the “Fine” function.
For this a Moiré test pattern could be used. If the Fine value is wrongly calibrated, the result would look like the left
drawing. The image should be homogeneous.
When FINE value is
wrong.When FINE value is
correct.
AUTO...

Page 13

English
English-11
EDID EXTENSION (Digital Input Only)
Selects the type of input to be used with EDID EXTENSION.
NORMAL: When a PC or other computer equipment is connected, select “NORMAL”.
ENHANCED: When a DVD player or other type of high definition device is connected, select “ENHANCED”.
NOTE:Interlaced signals (480i, 576i, 1080i) are not supported. If you have any problems, please refer to the
Troubleshooting section of this User’s Manual.
When EDID EXTENSION has been changed, the connected equipment...

Page 14

English-12
OSD LOCK OUT
This control completely locks out access to all OSD control functions. When attempting to activate OSD controls
while in the Lock Out mode, a screen will appear indicating the OSD controls are locked out.
There are four types of OSD LOCK OUT:
OSD LOCK OUT with BRIGHTNESS and CONTRAST control: To activate the OSD Lock Out function, press
SELECT, then “UP” button and hold down simultaneously. To deactivate the OSD Lock Out, press SELECT, then
“UP” button and hold down simultaneously...

Page 15

English
English-13
Recommended use
Safety Precautions and Maintenance
FOR OPTIMUM PERFORMANCE, PLEASE NOTE
THE FOLLOWING WHEN SETTING UP AND
USING THE LCD COLOR MONITOR:
•DO NOT OPEN THE MONITOR. There are no user serviceable parts inside and opening or removing covers may expose
you to dangerous shock hazards or other risks. Refer all servicing to qualified service personnel.
•Do not spill any liquids into the cabinet or use your monitor near water.
•Do not insert objects of any kind into the cabinet...

Page 16

English-14
CORRECT PLACEMENT AND ADJUSTMENT OF THE MONITOR CAN
REDUCE EYE, SHOULDER AND NECK FATIGUE. CHECK THE
FOLLOWING WHEN YOU POSITION THE MONITOR:
•For optimum performance, allow 20 minutes for warm-up.
•Adjust the monitor height so that the top of the screen is at or slightly below eye level.
Your eyes should look slightly downward when viewing the middle of the screen.
•Position your monitor no closer than 40 cm and no further away than 70 cm from your
eyes. The optimal distance is 50 cm.
•Rest...

Page 17

English
English-15
Specifications
Monitor Specifications MultiSync LCD2690WUXi2 Notes
LCD Module Diagonal: 64.9 cm/25.5 inches Active matrix; thin film transistor (TFT)
Viewable Image Size: 64.9 cm/25.5 inches liquid crystal display (LCD); 0.287 mm dot
Native Resolution (Pixel Count): 1920 x 1200 pitch; 320 cd/m
2 (250 cd/m2*3 portrait) white
luminence; 1000:1 contrast ratio, typical.
Input Signal Video: ANALOG 0.7 Vp-p/75 Ohms Digital Input: DVI (with HDCP)
Sync: Separate sync.TTL Level
Horizontal sync....

Page 18

English-16
Features
Ambix3 Technology: Triple input technology allowing up to 3 input sources to be connected to a single monitor. The DVI-I connector
supports both analog and digital input signals. Legacy analog input is supported using a traditional 15-pin VGA connector. Ambix3 provides
traditional technology compatibility for analog as well as DVI-based digital compatibility for digital inputs. DVI-based digital interfaces include
DVI-D, DFP and P&D.
DVI-I: The integrated interface ratified by the...

Page 19

English
English-17
Troubleshooting
No picture
•The signal cable should be completely connected to the display card/computer.
•The display card should be completely seated in its slot.
•Check the Vacation Switch should be in the ON position.
•Front Power Switch and computer power switch should be in the ON position.
•Check to make sure that a supported mode has been selected on the display card or system being used.
(Please consult display card or system manual to change graphics mode.)
•Check the monitor...

Page 20

English-18
Appendix
If you need detailed information about the controls, please use the advanced menu.

•Turn off your monitor.
•Turn on your monitor by pushing the “POWER” and “INPUT/SELECT” button at the same time for at least one second
simultaneously. Then press the control buttons (EXIT, LEFT, RIGHT, UP, DOWN).
•You will see the Advanced menu.
This menu is larger than the normal OSD.

•Turn off and restart your monitor in the normal way.
To make an adjustment, ensure that the tag is highlighted,...
Start reading NEC Multisync Lcd2690wuxi2 Users Manual

Related Manuals for NEC Multisync Lcd2690wuxi2 Users Manual

All NEC manuals