Page 11
English English-9 ECO MODE Decreases the amount of power consumed by reducing the brightness level. 1: Decreases the brightness by 25%. 2: Decreases the brightness by 50%. CUSTOM: Decreases the brightness level as determined by the user. Refer to the Advanced OSM menu for custom setting instructions. AUTO BRIGHTNESS There are three settings for Auto Brightness. OFF: No function. 1: Adjusts the brightness automatically, by detecting the brightness level of your environment and adjusting the monitor with...
Page 12
English-10 AUTO FINE (Analog input only) This function automatically and periodically adjusts the “FINE” setting for change in signal condition. This function adjusts approximately every 33 minutes. EXPANSION Sets the zoom method. FULL: The image is expanded to 1920 x 1200, regardless of the resolution. ASPECT: The image is expanded without changing the aspect ratio. OFF: The image is not expanded. CUSTOM: Refer to the ADVANCED OSM Controls menu section of the user’s manual for detailed instructions....
Page 13
English English-11 VIDEO DETECT Selects the method of video detection when more than one computer is connected. FIRST: The video input has to be switched to “FIRST” mode. When current video input signal is not present, then the monitor searches for a video signal from the other video input port. If the video signal is present in the other port, then the monitor switches the video source input port to the new found video source automatically. The monitor will not look for other video signals while the...
Page 14
English-12 OSM LOCK OUT This control completely locks out access to all OSM control functions. When attempting to activate OSM controls while in the Lock Out mode, a screen will appear indicating the OSM controls are locked out. There are four types of OSM LOCK OUT: OSM LOCK OUT with BRIGHTNESS and CONTRAST control: To activate the OSM Lock Out function, press SELECT, then “UP” button and hold down simultaneously. To deactivate the OSM Lock Out, press SELECT, then “UP” button and hold down simultaneously...
Page 15
English English-13 Recommended use Safety Precautions and Maintenance FOR OPTIMUM PERFORMANCE, PLEASE NOTE THE FOLLOWING WHEN SETTING UP AND USING THE LCD COLOUR MONITOR: •DO NOT OPEN THE MONITOR. There are no user serviceable parts inside and opening or removing covers may expose you to dangerous shock hazards or other risks. Refer all servicing to qualified service personnel. •Do not spill any liquids into the cabinet or use your monitor near water. •Do not insert objects of any kind into the cabinet...
Page 16
English-14 CORRECT PLACEMENT AND ADJUSTMENT OF THE MONITOR CAN REDUCE EYE, SHOULDER AND NECK FATIGUE. CHECK THE FOLLOWING WHEN YOU POSITION THE MONITOR: •For optimum performance, allow 20 minutes for warm-up. •Adjust the monitor height so that the top of the screen is at or slightly below eye level. Your eyes should look slightly downward when viewing the middle of the screen. •Position your monitor no closer than 40 cm and no further away than 70 cm from your eyes. The optimal distance is 50 cm. •Rest...
Page 17
English English-15 Specifications Monitor Specifications MultiSync LCD2690WUXi and Notes SpectraView 2690 Monitor LCD Module Diagonal: 64.9 cm/25.5 inches Active matrix; thin film transistor (TFT) Viewable Image Size: 64.9 cm/25.5 inches liquid crystal display (LCD); 0.287 mm dot Native Resolution (Pixel Count): 1920 x 1200 pitch; 400 cd/m 2 white luminence; 800:1 contrast ratio, typical. Input Signal Video: ANALOG 0.7 Vp-p/75 Ohms Digital Input: DVI (with HDCP) Sync: Separate sync.TTL Level Horizontal...
Page 18
English-16 Features Ambix3 Technology: Triple input technology allowing up to 3 input sources to be connected to a single monitor. The DVI-I connector supports both analog and digital input signals. Legacy analog input is supported using a traditional 15-pin VGA connector. Ambix3 provides traditional technology compatibility for analog as well as DVI-based digital compatibility for digital inputs. DVI-based digital interfaces include DVI-D, DFP and P&D. DVI-I: The integrated interface ratified by the...
Page 19
English English-17 Troubleshooting No picture •The signal cable should be completely connected to the display card/computer. •The display card should be completely seated in its slot. •Check the Vacation Switch should be in the ON position. •Front Power Switch and computer power switch should be in the ON position. •Check to make sure that a supported mode has been selected on the display card or system being used. (Please consult display card or system manual to change graphics mode.) •Check the monitor...
Page 20
English-18 Appendix If you need detailed information about the controls, please use the advanced menu. •Turn off your monitor. •Turn on your monitor by pushing the “POWER” and “INPUT/SELECT” button at the same time for at least one second simultaneously. Then press the control buttons (EXIT, LEFT, RIGHT, UP, DOWN). •You will see the Advanced menu. This menu is larger than the normal OSM. •Turn off and restart your monitor in the normal way. To make an adjustment, ensure that the tag is highlighted,...