    							Command Codes (continued)
    No. Function Code Data Description
    99
    SPECIFICATIONS100 32
    Display Mode Select1FH Yes 0 Normal Aspect
    1 Wide Aspect
    33
    Power Management On15H No
    34
    Power Management Off16H No
    35 Digital Zoom W 89H No Same as remote
    36 Digital Zoom T 8AH No Same as remote
    37 Brightness 60H Yes 0 (00H) ÐÐ 63 (3FH)
    38 Contrast 62H Yes 0 (00H) ÐÐ 63 (3FH)
    39 Color 64H Yes 0 (00H) ÐÐ 63 (3FH)
    40 Tint 66H Yes -32 (E0H) ÐÐ 31 (1FH)
    41 Sharpness 68H Yes 0 (00H) ÐÐ 63 (3FH)
    42 Audio Volume 6AH Yes 0 (00H) ÐÐ 63 (3FH)
    43 Picture Adj 70H Yes -32 (
    FFE0H) ÐÐ 31 (001FH)
    44 Fine Picture 6EH Yes 0 (00H) ÐÐ 127 (7FH)
    45 H Position 72H Yes -128 (80H) ÐÐ 127 (7FH)
    46 V Position 74H Yes -64 (C0H) ÐÐ 63 (3FH)
    47 Lamp Reset 3FH No
    48 Lamguage Select 3DH Yes 0 English
    1 German
    2 French
    3 Italian
    4 Spanish
    5 Swedish
    6 Japanese
    WHITE BALANCE
    49 Sub Brightness R 75H Yes 0 (00H) ÐÐ 63 (3FH)
    50 Sub Brightness G 76H Yes 0 (00H) ÐÐ 63 (3FH)
    51 Sub Brightness B 77H Yes 0 (00H) ÐÐ 63 (3FH)
    52 Sub Contrast R 78H Yes 0 (00H) ÐÐ 63 (3FH)
    53 Sub Contrast G 79H Yes 0 (00H) ÐÐ 63 (3FH)
    54 Sub Contrast B 7AH Yes 0 (00H) ÐÐ 63 (3FH) 
    						
    							Cable Connection
    Communication Protocol
    Baud rate: 9600 bps
    Data length: 8 bits
    Parity: No parity
    Stop bit: One bit
    X on/off: None
    CommunicationsFull duplex
    procedure:
    If the CPU of the projector has received the data correctly, it returns an ACK(C5H). If the received data is not correct, the CPU returns a
    NAK(CAH), then the following status:
    Receiving success: C5
    Receiving failure: CA Err
    Err 01: Command Error (command not supported)
    Err 02: Checksum Error
    Err 03: Busy (command not acceptable)
    101
    44 Err 04: Parameter Error ( parameter data abnormal)
    1 2 54 36
    7 8
    To RxD of PC©PC Control Connector (DIN-8P)
    NOTE:  If failing in powering-on, the CPU returns the following NAKs:
    CA Err 1
    Err 1 8X (Apply the corresponding bit.)
    Bit 0: Lamp housing is not attached correctly
    Bit 1: Fan stoppage
    Bit 2: Overheated
    Bit 3: Lamp lighting failure
    To TxD of PC§To GND of PC©