    							B-13 Intel ICH7R SATA RAID
    Select the folder in which you want the program to be installed in the following
    window, and click Next button to start installation.
    Select a program folder in the following window where you want Setup to add the
    program icon.7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3113 
    						
    							MS-7528 Mainboard
    B-14Once the installation is complete, the following window appears. The following window appears to show the Intel Application Accelerator RAID Edition
    Setup installation status.7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3114 
    						
    							B-15 Intel ICH7R SATA RAIDRAID Migration InstructionsImportant
    A Create from Existing Disk operation will delete all existing data from the
    added disk and the data cannot be recovered. It is critical to backup all
    important data on the added disk before proceeding. However, during the
    migration process, the data on the source disk is preserved. The Intel Matrix Storage Console offers the flexibility to upgrade from a single Serial
    ATA (SATA) hard drive to RAID configuration when an additional SATA hard drive is
    added to the system. This process will create a new RAID volume from an existing
    disk. However, several important steps must be followed at the time the system is
    first configured in order to take advantage of RAID when upgrading to a second
    SATA hard drive:
    1.BIOS must be configured for RAID before installing Windows XP on the
    single SATA hard drive. Refer to On Chip SATA Setting for properly
    setting of the BIOS.
    2.Install the Intel Application Accelerator RAID Driver during Windows Setup.
    Refer to Installing Software for instructions on installing the driver dur-
    ing Windows Setup.
    3.Install the Intel Matrix Storage Console after the operating system is installed.
    To create a volume from an existing disk, complete the following steps:
    After the Intel Matrix Storage Console has been successfully installed and the sys-
    tem has rebooted, click on the Intel Application Accelerator shortcut link (Start --> All
    Programs --> Intel Matrix Storage Manager --> Intel Matrix Storage Console)
    and the following window will appear:7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3115 
    						
    							MS-7528 Mainboard
    B-16Create RAID Volume from Existing Disk
    To create a RAID volume from an existing disk, choose Action --> Create RAID
    Volume from Existing Hard Drive.The Create RAID Volume from Existing Hard Drive Wizard pops up to lead you
    for the following procedure. Click Next to continue.7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3116 
    						
    							B-17 Intel ICH7R SATA RAID
    (1) Step 1: Configure Volume
    Here you can configure the new RAID volume by entering the volume name, selecting
    the RAID level and strip size.† RAID Volume Name:
    A desired RAID volume name needs to be typed in where the ‘RAID_Volume1’ text
    currently appears above. The RAID volume name has a maximum limit of 16 characters.
    The RAID volume name must also be in English alphanumeric ASCII characters.
    † RAID Level:
    Select the desired RAID level:
    RAID 0 (Performance) –A volume optimized for performance will allow you to
    access your data more quickly.
    RAID 1 (Redundancy) –A volume optimized for data redundancy will provide
    you with a realtime duplicate copy of your data. Note:
    Only half of the available volume space will be avail-
    able for data storage.
    RAID 5 (Useful) –RAID 5 can be used on three or more disks, with zero
    or more spare-disks. The resulting RAID-5 device size
    will be (N-1)*S, where N is the how many drive, S is the
    size of the smallest drive in the array. If one of the disks
    fail, all data are still intact. It can rebuild the disk from
    the parity information. If spare disks are available, re-
    construction will begin immediately after the device
    failure. If two disks fail simultaneously, all data are lost.
    RAID-5 can survive one disk failure, but not two or
    more. Both read and write performance usually
    increase, but can be hard to predict how much. Reads
    are similar to RAID-0 reads, writes can be either rather7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3117 
    						
    							MS-7528 Mainboard
    B-18expensive (requiring read-in prior to write, in order to
    be able to calculate the correct parity information), or
    similar to RAID-1 writes. The write efficiency depends
    heavily on the amount of memory in the machine, and
    the usage pattern of the array. Heavily scattered writes
    are bound to be more expensive.
    RAID 10 (Mirrored Stripes) –A RAID 1 array of two RAID 0 arrays.
    † Strip Sizes:
    Select the desired strip size setting. As indicated, the optimal setting is 128KB. Se-
    lecting any other option may result in performance degradation. Even though 128KB
    is the recommended setting for most users, you should choose the strip size value
    which is best suited to your specific RAID usage model. The most typical strip size
    settings are:
    4KB: For specialized usage models requiring 4KB strips
    8KB: For specialized usage models requiring 8KB strips
    16KB: Best for sequential transfers
    32KB: Good for sequential transfers
    64KB: Good general purpose strip size
    128KB: Best performance for most desktops and workstations
    (2) Select the source disk
    Then select the source disk that you wish to use and then click “--->” to move it to the
    Selected field. Then click Next to continue.
    It is very important to note which disk is the source disk (the one containing all of the
    information to be migrated) and which one is the target disk. On a RAID Ready
    system, this can be determined by making a note during POST of which port (e.g. Port
    0 or Port 1) the single disk is attached to.
    You can also use the Intel Application Accelerator RAID Edition utility before the
    second disk is installed to verify the Port and serial number of the drive that contains
    all the data.7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3118 
    						
    							B-19 Intel ICH7R SATA RAID
    (3) Select Member Hard Drive(s)
    Then select the member disk (the target disk) that you wish to use and then click “-
    -->” to move it to the Selected field. Then click Next to continue.
    Please note that the existing data on the selected hard drive(s) will be deleted
    permanently. Do not forget to back up all the important data before continuing.7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3119 
    						
    							MS-7528 Mainboard
    B-20(4) Specify Volume Size
    Specify the amount of available array space to be used by the new RAID volume. You
    may enter the amount in the space or use the slider to specify. It is recommended you
    use 100% of the available space for the optimized usage. For RAID 0 volume, if you
    do not specify 100% of the hard drive space, the rest hard drive space will be
    worked as RAID 1 volume, which is the new technology called Intel Matrix RAID. Then
    click Next to continue.(5) Start Creating RAID Volume from Existing Hard Drive Wizard
    Before you continue the procedure of RAID volume creation from existing hard drive,
    read the dialogue box below carefully. Please note that once you click Finish, the
    existing data on the selected hard drive(s) will be deleted permanently and this
    operation cannot be undone. It is critical that you backup all important data before
    selecting Finish to start the migration process.7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3120 
    						
    							B-21 Intel ICH7R SATA RAID
    (6) Start Migration
    The migration process may take up to two hours to complete depending on the size
    of the disks being used and the strip size selected. A dialogue window will appear
    stating that the migration process may take considerable time to complete, meanwhile
    a popup dialogue at the taskbar will also show the migration status. While you can still
    continue using your computer during the migration process, once the migration proc-
    ess starts, it cannot be stopped. If the migration process gets interrupted and your
    system is rebooted for any reason, it will pick up the migration process where it left
    off. You will be provided with an estimated completion time (the remaining time will
    depend on your system) once the migration process starts.
    The following screen appears if the migration process is completed successfully.
    Then you have to reboot your system to use the full capacity of the new volume.7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3121 
    						
    							MS-7528 Mainboard
    B-22A RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its hard
    drive members fails or is temporarily disconnected, and data mirroring is lost. As a
    result, the system can only utilize theremaining functional hard drive member. To re-
    establish data mirroring and restore data redundancy, refer to the procedure below
    that corresponds to the current situation.
    Missing Hard Drive Member
    1. Make sure the system is powered off.
    2. Reconnect the hard drive.
    3. Reboot the system to Windows; the rebuild will occur automatically.
    Failed Hard Drive Member
    1. Make sure the system is powered off.
    2. Replace the failed hard drive with a new one that is of equal or greater
    capacity.
    3. Reboot the system to Intel RAID Option ROM by press  and  keys
    simultaneously during the Power-On Self Test (POST).Degraded RAID Array
    4. Select the port of the destination disk for rebuilding, and then press ENTER.7528v1.0-B_ICH7R RAID.p65  2008/2/1, 下午 04:3122 
    						
    All MSI manuals Comments (0)