11 MTH500 Portable Radio Basic Service Manual - TEST SETUP & TESTING Note: The displayed values are factory defaults and should not be changed. NEIGHBOUR CELL BROADCAST: NOT REQUIRED BROADCAST INTERVAL: 10s NEIGHBOUR CELL CHANNEL: 0000 NEIGHBOUR CELL LOCATION AREA: 00000 NEIGHBOUR CELL IDENTIFIER: 01 SLOW RE-SELECT THRESHOLD: 10dB PRESS “MORE” SOFT KEY SLOW RE-SELECT HYSTERESIS: 10dB FAST RE-SELECT THRESHOLD: 10dB FAST RE-SELECT HYSTERESIS: 10dB 22. Press the “Return” soft key. 23. Press the “Trunk Type” soft key and “Tx Trunked” soft key. 24. Press “More” Softkey. Note: The displayed values are factory defaults and should not be changed. It is not required to configure “Call Types” and “Messages”. 25. Press “More” Softkey. How to Configure the IFR 2968 Manual Test Screen 1. To enter “Manual test” screen, press “Manual” soft key. 2. Press “Control Channel” soft key. Thereafter, enter “3605” for R1 and “880” for R2 and press “Control Channel” soft key (IFR 3605 = Rx 390.125MHz) for R1 and (IFR 880 = Rx 422.0125MHz) for R2.
TEST SETUP & TESTING: RF Tests 12 3. Press “Traffic Channel” soft key. Enter “3700” for R1 and “900” for R2 and press “Traffic Channel” soft key. The marker goes to Timeslot. Enter “3” and press “Traffic Channel” soft key. (Note that the Traffic Channel number changes automatically after entering the Control Channel number). 4. Press “RF Gen Level” soft key. Thereafter, enter “-50” and press “dBm” data keys followed by “RF Gen Level” soft key. 5. Press “Mobile Power” soft key, enter 30 dBm/1W, using soft key. 6. Press “Burst Type” soft key and “Normal” soft key. 7. This completes the test equipment configuration setup. Note: The System Setup Configuration Data is saved even after the power is turned off. However, the Manual Test Setup is not saved. RF Tests Receiver Tests Simulate Base Station (registration) 1. Turn the radio ON 2. Check that registration and “ITSI: ---/----/00000xxx” is displayed on the IFR “Manual Test” screen. Status: Registered (ITSI Attach) RSSI Test Before carrying out the following steps, record the Insertion loss (dB) of the cable loss value - (X) dB. Also, 0.5 dB, the maximum insertion loss of the Antenna assembly adapter should be added to the total calculated insertion loss. 1. In the IFR Manual Test Mode, press the “RF Gen Level” Soft Key and enter (–) 80dbm.
13 MTH500 Portable Radio Basic Service Manual - TEST SETUP & TESTING 2. Before testing, the radio should be configured to RSSI mode using the follow- ing Sequence, When performing steps 3 thru 6, make sure that you press the handset keys sequentially (less then a second between every consecutive press). 3. Press the “Volume down” Key. 4. Press the “1 “key, and “Menu” Key. 5. Press the “2 “key, and “Menu” Key. 6. Press the “3 “key. Hereafter, there is no need for quick sequence of pressing the handset keys. 7. Press Key to enter the “4 Cells Info” state. 8. Press “OK” using the Right ( .) Key and press . 9. Press “Trace” using the Right ( .) Key. Note:RSSI results will flash on the screen every few seconds. The display shows: SERV: xx RSSI: -81 SQE: xx Disregard the “SERV” and “SQE” results. The actual measured result should be: {-80dBm (IFR RF Gen Level) -0.5dB(adapter)-XdB (cable)} +/-1 dB. RSSI = {Radio RSSI Result – [Antenna assembly Adapter (dB) + Insertion loss of the Cable (dB)]}. To stop the “Trace” process, perform the following. When performing steps 10. thru 13., make sure that you press the handset keys sequentially (less then a sec- ond between every consecutive press): 10. Press the “Volume down” Key. 11. Press the “1” key, and “Menu” Key. 12. Press the “2” key, and “Menu” Key. 13. Press the “3” key. 14. Press “Stop” using the Right ( .) Key.
TEST SETUP & TESTING: Call Processing Test 14 15. Press “Back” twice using the Left (.) Key. Transmitter Tests 1. Change the “Mode Key” of the radio to “Group Mode”. 2. Press the “RF Gen Level” soft key. Enter “-90dBm” by pressing the data keys and “RF Gen Level” Key. 3. Press the “PTT” of the radio and monitor the IFR “Manual Test” screen which displays the Burst Power, Power Profile, Timing Error, Vector Error, and Fre- quency Error. Note: You have to hold the PTT in the pressed position long enough to enable you to read the results. - Burst Power Required Results: 28-32dbm. - Power Profile: Passed. - Timing Error: < 0.25 symbols. - Vector Error: Max 10% RMS, Max 30% Peak. - Max 5% residual. - Frequency Error: -/+ 100Hz. 4. Press the “Clear Down” soft key, to proceed with other tests. Call Processing Test Ta l k B a c k Before you start this test, make sure that handset and test equipment are config- ured the same as given in the Transmitter Test. 1. Press the “PTT” and speak into the mic of the radio. You will hear the last three seconds of the speech frames before the “PTT” is released.
15 MTH500 Portable Radio Basic Service Manual - TEST SETUP & TESTING 2. Press the “Test Sound” soft key to provide the 1kHz signal to the radio speaker. 3. Press the “Silence” soft key to mute the 1KHz Audio Signal of the speaker. 4. Press the “Clear Down” soft key and check that the “Cleardown Complete” status appear on the IFR “Manual Test” screen. Call to Mobile 1. Press the radio “Mode” key and change to “Private” mode. 2. Press the “Call Mobile” soft key on the IFR. Note: Select type of call. 3. Press “Private” Call. Note: You will hear beeps from the handset speaker. 4. Press “Abort Call” soft key.Duplex Test (Phone/Privet Mode) Digital Duplex Test (Tx) 1. Press the “Mode” key of the radio and select “Phone” or “Privet” mode. 2. Dial a random number “9359” using the Alphanumeric keys of the radio and press the “Send” Key. The following results are displayed on the IFR “Manual Test” Screen. - Burst Power Required Results: 28-32dbm - Power Profile: Passed - Timing Error:
16 3. Speak into the Handset Microphone and hear your speech (after a short delay) from the handset Earpiece. Note: If you need more details, press the “Duplex Test” mode key. 4. Press the “duplex test (Tx)” soft key twice. The “Digital Duplex test” results will be displayed on the IFR screen providing you with the following bar charts measurement capabilities: - Power - Vector RMS - Frequency Error For Power Analyser Graph: 5. Press “power ana” soft key. 6. Check that the power frame falls within the limits. For Spectrum Analyser Graph: 7. Press “Spect ana” soft key. 8. Monitor the Tx frequency. For Vector Analyser Diagram: 9. Press the “Vect Anal” soft key 10. Monitor the constellation diagram. 11. Press the “Vector Diagram” soft key. 12. Press the “Rotated vector” to zoom in on the constellation. 13. Press the handset “End” key.
17 MTH500 Portable Radio Basic Service Manual - TEST SETUP & TESTING DMO Test IFR 2968 Test Setup 1. Press the “System” softkey. 2. Press “TETRA Direct” Softkey. 3. Press “Setup” Softkey. 4. Press “Channel Plan” Softkey, press “TETRA 380+ODM” softkey for R1or TETRA 410+ODM for R2. 5. Press DM Tx Mode” softkey, press “discontinue” softkey How to Configure the IFR 2968 Manual Test Screen 1. Press the “Manual” softkey. 2. Press “Channel” Softkey, thereafter enter “4000= 390 MHz” for R1or “1200=420 MHz for R2 and press “Channel” softkey. 3. Press “Expected Power” Softkey, enter 30.0dBm/1.0 w. 4. Press “Burst Type” Softkey and “Normal” softkey. Radio Configuration for DMO Modify the radio for DMO option by carrying out the following sequence: 1. Turn ON the radio. 2. Press the “Menu” key 3. Press key and select mode “network”, press “OK” softkey. 4. Select “OPERMODE”, and press “OK” softkey. 5. Select “DIRECMODE” softkey and press “OK” softkey .
TEST SETUP & TESTING: DMO Test 18 RF Test - Transmit Test Hold the PTT in the pressed position long enough to enable you to read the results: •Results: - Power Profile: Passed •Burst Power Request Results: 28-32 dBm •Frequency Error: +/- 100Hz max. •Vector Error: Max. 10% RMS, Max. 30% Peak, Max. 5% Residual.
19 MTH500 Portable Radio Basic Service Manual - PROGRAMMING THE RADIO CHAPTER 3 PROGRAMMING THE RADIO Before Using the Customer Programming Software (CPS) Before you begin programming, ensure the following: •That your radio battery is fully charged. •That you have connected the Data cable (FKN4897), according to Figure 2. •That the Customer Programming Software (CPS) is installed in your computer. Figure 2. Setup for Radio Programming. MTH500Radio p Serial Port (COM1/2) To MTH500 Accessory Connecto r Data Cable (FKN4897)
PROGRAMMING THE RADIO: Programming the Radio 20 Programming the Radio 1. Verify that the radio is turned off. 2. Run the Customer Programming Software (CPS) on your computer. 3. Press the “1” and “9” keys together and then the On/Off key for about 3 sec- onds. Verify that no display appears on the LCD screen. 4. Click the Toolbar “Read Phone” icon. Refer to the CPS Application Window Screen in the CPS User Guide, Publication No. 68P02956C20. The setup enters an initialization process that takes about 20 seconds. After that, a read- ing process starts. Note:While reading is in progress, the radio screen displays the following data: A progress bar appear on the computer screen. After the reading process is finished, the radio Codeplug screen appears. CodePlug Programming 1. On the menu bar, click “File” “Open”. 2. Browse for the required Codeplug file and open the file. 3. The Codeplug window appears on the screen. 4. Click the Toolbar “Tools” and select “Write Entire Codeplug”. Diag. SW Ver. 01.01 HW ID Code: XXX Flash: TE28F320C3BA Command READ REQ. 00:00:00 --Done-- Elapsed Time Indication Appears at the end of the process