Miele K 1901 Vi Operating And Installation Instructions
Have a look at the manual Miele K 1901 Vi Operating And Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 171 Miele manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: –your Miele Dealer or –Miele (see back cover for contact details). When contacting your Dealer or Miele, please quote the model and serial number of your appliance. This information is given on the data plate inside your appliance. Please note that telephone calls may be monitored and recorded for training purposes. N.B. A call-out charge will be applied for service visits where the problem could have been resolved as described in these instructions. Guarantee For information on the appliance guarantee specific to your country please contact Miele. See back cover for contact details. In the U.K. your appliance is guaranteed for 2 years from the date of purchase. However, you must activate your cover by calling 0845 365 6640 or registering online at www.miele.co.uk. After Sales / Guarantee 41
Electrical connection U.K. All electrical work should be carried out by a suitably qualified and competent person in strict accordance with current local and national safety regulations (BS 7671 in the UK). The appliance is supplied with a mains cable and moulded plug ready for connection to an a.c. single phase 220-240 V 50 Hz supply. Please ensure that the connection data quoted on the data plate match the household mains supply. Connection should be made via a suitable switched socket which is easily accessible. For extra safety it is advisable to protect the appliance with a suitable residual current device (RCD). Do not connect the appliance to the mains electricity supply by an extension lead. Extension leads do not guarantee the required safety of the appliance (e.g. danger of overheating). This appliance must not be connected to the inverter of an autonomous power supply, e.g. a solar power system. When switching the appliance on, a surge in power could trigger the safety cut-out mechanism. This could damage the electronic unit. The appliance must not be used with so-called energy saving devices. These reduce the energy supply to the appliance which could then become too warm. Using such devices could alter the specification of the product.Non-rewireable plugs (BS 1363) The fuse cover must be re-fitted when changing the fuse, and if the fuse cover is lost, the plug must not be used until a suitable replacement is obtained. The colour of the correct replacement cover is that of the coloured insert in the base of the plug, or the colour that is embossed in words in the base of the plug (as applicable to the design of the plug fitted). Replacement fuses should be ASTA approved to BS 1362 and have the correct rating. Replacement fuses and fuse covers may be purchased from your local electrical supplier. WARNING THIS APPLIANCE MUST BE EARTHED Electrical connection 42
Location This appliance should be installed in a dry, well-ventilated room. It should not be installed where it is exposed to direct sunlight or directly adjacent to a heat-producing appliance such as an oven or a radiator. The room temperature should not go above or below the climate range for which the appliance is designed. The higher the ambient temperature of the room, the more energy the appliance requires to operate. If installation near a heat source is unavoidable, observe the following distances between the appliance and the heat source: – 3 cm away from an electric oven or cooker – 30 cm away from an oil- or coal-fired range.Important: tropical / humid environments During periods of high humidity, some condensation may appear on outside surfaces of cooling appliances. This condensation will disappear when humidity levels drop. For prevention, it is advisable to install the appliance with sufficient ventilation in a dry and/or an air-conditioned room. Please ensure that doors are closing and sealing properly. Please ensure that the appliance is installed in accordance with these installation instructions and that the handle is fitted correctly. Should you require further assistance please contact your Miele customer service centre. Climate range The appliance is designed for use within certain climate ranges (ambient temperatures) and should not be used outside this range. The climate range of the appliance is stated on the data plate inside the appliance. Climate range Ambient room temperature SN N ST T+10 °C to +32 °C +16 °C to +32 °C +16 °C to +38 °C +16 °C to +43 °C Operating in a room which is too cold will result in the cooling system switching off for too long, causing the internal temperature in the appliance to rise. Installation advice 43
Safe operation of the appliance is only assured if it has been installed and connected in accordance with these operating and installation instructions. Warning! This appliance is very heavy and can tip forwards when the door is open. Keep the door shut until the appliance has been built in and secured within the building-in niche in accordance with these instructions. Due to the size and weight of the appliance, installation must be carried out by two people. The weight of the appliance when empty is: K 1801 Vi, K 1811 Vi.........189kg K 1901 Vi, K 1911 Vi.........205kg Floor To ensure the safe installation of the appliance and to guarantee its correct functioning, the floor to the niche where the appliance is to be installed must be smooth and even. It must be made from strong, rigid material. The appliance is extremely heavy when fully loaded, and for this reason it is imperative that the floor it stands on is able to bear its weight. If necessary, the advice of an architect or structural engineer should be sought. When fully loaded, the approx. weight of the appliance is: K 1801 Vi, K 1811 Vi.........452kg K 1901 Vi, K 1911 Vi.........540kg Door hinging The appliance is supplied with fixed hinges. If you need to change the door hinging to the other side, please contact the Service Department. On no account should you attempt to change the door hinging yourself. (N.B. Door hinge change not available in all countries). Adjoining furniture/units The appliance is screwed to the adjoining furniture/units to the side and above. For this reason, it is essential that all furniture/units be fixed to the ground and/or wall. Installation advice 44
Ventilation The ventilation gaps must not be covered or blocked in any way. They should be dusted on a regular basis. Side-by-side installation This appliance may be installed side-by-side with another suitable refrigerator or freezer. A side-by-side installation kit, available from Miele, is required. Ask your dealer which appliances are suitable for side-by-side installation with this appliance. See the instructions supplied with the side-by-side installation kit for how to fix the appliances together. Joining the appliances together with the side-by-side installation kit If the appliances are to be installed next to each other without a partition wall between them, they will need to bejoined together using the side-by-side installation kit. Installation with a partition wall using the side-by-side installation kit The partition wall must be at least 16 mm thick. If the partition wall between the two appliances isbetween 16 mm and 160 mmthick, each appliance must be built into its own niche using the assembly parts supplied. The side-by-side installation kit is also required. Installation with a partition wall without the side-by-side installation kit If the partition wall between the two appliances ismore than 160mm, each appliance must each be built into its own niche using the assembly parts supplied (without using the side-by-side installation kit). Installation advice 45
To limit the opening angle of the door The door hinges are set ex-works to enable the door to be opened wide. However, if the appliance door hits an adjacent wall when opened, for example, the opening angle can be limited to 90°. Open the appliance door. Insert the pin into the hinge from above, as shown. The door opening angle is now limited to 90°. Installation advice 46
Appliance door dimensions (opening angle 90°) *The dimensions for the door fronts and handles will vary according to the individual kitchen. AB C K 1801 Vi, K 1811 Vi829 mm Door front (max. 38 mm)* Door handle* K 1901 Vi, K 1911 Vi982 mm Door front (max. 38 mm)* Door handle* Appliance door dimensions (opening angle 115°) *The dimensions for the door fronts and handles will vary according to the individual kitchen. AB CD K 1801 Vi, K 1811 Vi829 mm Door front (max. 38 mm)* Door handle* 363 mm K 1901 Vi, K 1911 Vi982 mm Door front (max. 38 mm)* Door handle* 428 mm Installation advice 47
Niche width A K 1801 Vi, K 1811 Vi762 – 765 mm K 1901 Vi, K 1911 Vi915 – 918 mm Building-in dimensions 48
Laying the electrical cabling Door front dimensions AB K 1801 Vi, K 1811 Vi2029 mm 756 mm K 1901 Vi, K 1911 Vi2029 mm 908 mm Building-in dimensions 49
Due to the size and weight of the appliance, it is essential that installation is carried out by two people. Tools and accessories required –Cordless screwdriver –Torx screwdriver –Hammer drill –Drill bits in various sizes, depending on materials – Hammer – 8 mm socket wrench – Adhesive tape – Pipe wrench – Spirit level – Try-square To secure the housing unit to a wall behind: – suitable wall plugs/fixing screws for the type and material of the wall.Other –Step ladder –Sack barrow –Wooden beams (min. 75 mm x 100 mm) if required, to prevent tipping; length depends on width of building-in niche –Wood screws in various sizes Optional accessory –Side-by-side installation kit for side-by-side installation of two appliances Installation 50