Home > Miele > Fridge freezer > Miele F 1811 Vi Operating And Installation Instructions

Miele F 1811 Vi Operating And Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Miele F 1811 Vi Operating And Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 171 Miele manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Electrical connection U.K.
    All electrical work should be carried out
    by a suitably qualified and competent
    person in strict accordance with current
    local and national safety regulations
    (BS 7671 in the UK).
    The appliance is supplied with a mains
    cable and moulded plug ready for
    connection to an a.c. single phase
    220-240 V 50 Hz supply.
    Please ensure that the connection data
    quoted on the data plate match the
    household mains supply.
    Connection should be made via a
    suitable switched socket which is easily
    accessible. For extra safety it is
    advisable to protect the appliance with
    a suitable residual current device
    (RCD).
    Do not connect the appliance to the
    mains electricity supply by an extension
    lead. Extension leads do not guarantee
    the required safety of the appliance
    (e.g. danger of overheating).
    This appliance must not be connected
    to the inverter of an autonomous power
    supply, e.g. a solar power system.
    When switching the appliance on, a
    surge in power could trigger the safety
    cut-out mechanism. This could damage
    the electronic unit.
    The appliance must not be used with
    so-called energy saving devices. These
    reduce the energy supply to the
    appliance which could then become
    too warm. Using such devices could
    alter the specification of the product.Non-rewireable plugs (BS 1363)
    The fuse cover must be re-fitted when
    changing the fuse, and if the fuse cover
    is lost, the plug must not be used until a
    suitable replacement is obtained. The
    colour of the correct replacement cover
    is that of the coloured insert in the base
    of the plug, or the colour that is
    embossed in words in the base of the
    plug (as applicable to the design of the
    plug fitted).
    Replacement fuses should be ASTA
    approved to BS 1362 and have the
    correct rating. Replacement fuses and
    fuse covers may be purchased from
    your local electrical supplier.
    WARNING
    THIS APPLIANCE MUST BE
    EARTHED
    Electrical connection
    51
     
    						
    							Location
    This appliance should be installed in a
    dry, well-ventilated room. It should not
    be installed where it is exposed to
    direct sunlight or directly adjacent to a
    heat-producing appliance such as an
    oven or a radiator. The room
    temperature should not go above or
    below the climate range for which the
    appliance is designed. The higher the
    ambient temperature of the room, the
    more energy the appliance requires to
    operate.
    If installation near a heat source is
    unavoidable, observe the following
    distances between the appliance and
    the heat source:
    – 3 cm away from an electric oven or
    cooker
    – 30 cm away from an oil- or coal-fired
    range.Important: tropical / humid
    environments
    During periods of high humidity,
    some condensation may appear on
    outside surfaces of cooling
    appliances. This condensation will
    disappear when humidity levels
    drop. For prevention, it is advisable
    to install the appliance with sufficient
    ventilation in a dry and/or an
    air-conditioned room.
    Please ensure that doors are closing
    and sealing properly.
    Please ensure that the appliance is
    installed in accordance with these
    installation instructions and that the
    handle is fitted correctly. Should you
    require further assistance please
    contact your Miele customer service
    centre.
    Climate range
    The appliance is designed for use
    within certain climate ranges (ambient
    temperatures) and should not be used
    outside this range. The climate range of
    the appliance is stated on the data
    plate inside the appliance.
    Climate range Ambient room
    temperature
    SN
    N
    ST
    T+10 °C to +32 °C
    +16 °C to +32 °C
    +16 °C to +38 °C
    +16 °C to +43 °C
    Operating in a room which is too cold
    will result in the cooling system
    switching off for too long, causing the
    internal temperature in the appliance to
    rise with the risk of food deteriorating
    and going off or frozen food defrosting.
    Installation advice
    52
     
    						
    							Safe operation of the appliance is
    only assured if it has been installed
    and connected in accordance with
    these operating and installation
    instructions.
    Warning!
    This appliance is very heavy and
    can tip forwards when the door is
    open. Keep the door shut until the
    appliance has been built in and
    secured within the building-in niche
    in accordance with these
    instructions.
    Due to the size and weight of the
    appliance, installation must be
    carried out by two people.
    The weight of the appliance when
    empty is:
    F 1811 Vi.................. 191kg
    F 1911 Vi..................208kg
    Installation advice
    53
     
    						
    							Floor
    To ensure the safe installation of the
    appliance and to guarantee its correct
    functioning, the floor to the niche where
    the appliance is to be installed must be
    smooth and even.
    It must be made from strong, rigid
    material.
    The appliance is extremely heavy when
    fully loaded, and for this reason it is
    imperative that the floor it stands on is
    able to bear its weight. If necessary, the
    advice of an architect or structural
    engineer should be sought.
    When fully loaded, the approx. weight
    of the appliance is:
    F 1811 Vi.................. 430kg
    F 1911 Vi..................510kg
    Door hinging
    The appliance is supplied with fixed
    hinges. If you need to change the
    door hinging to the other side,
    please contact the Service
    Department.
    On no account should you attempt
    to change the door hinging yourself.
    (N.B. Door hinge change not
    available in all countries).
    Adjoining furniture/units
    The appliance is screwed to the
    adjoining furniture/units to the side and
    above.
    For this reason, it is essential that all
    furniture/units be fixed to the ground
    and/or wall.
    Ventilation
    The ventilation gaps must not be
    covered or blocked in any way.
    They should be dusted on a regular
    basis.
    Installation advice
    54
     
    						
    							Side-by-side installation
    This appliance may be installed
    side-by-side with another suitable
    refrigerator or freezer.
    A side-by-side installation kit,
    available from Miele, is required.
    Ask your dealer which appliances
    are suitable for side-by-side
    installation with this appliance.
    See the instructions supplied with
    the side-by-side installation kit for
    how to fix the appliances together.
    Joining the two appliances together
    with the side-by-side installation kit
    If the appliances are to be installed
    next to each other without a partition
    wall between them, they will need to be
    joined together using the side-by-side
    installation kit.Installation with a partition wall using
    the side-by-side installation kit
    The partition wall must be at least
    16 mm thick.
    If the partition wall between the two
    appliances isbetween 16 mm and
    160 mmthick, each appliance must be
    built into its own niche using the
    assembly parts supplied. The
    side-by-side installation kit is also
    required.
    Installation with a partition wall
    without the side-by-side installation
    kit
    If the partition wall between the two
    appliances ismore than 160mm, each
    appliance must each be built into its
    own niche using the assembly parts
    supplied (without using the
    side-by-side installation kit).
    Installation advice
    55
     
    						
    							Appliance door dimensions (opening angle 115°)
    AB CD
    F 1811 Vi829 mm Door front (max. 38 mm)* Door handle* 363 mm
    F 1911 Vi982 mm Door front (max. 38 mm)* Door handle* 428 mm
    * The dimensions for the door fronts and handles will vary according to the
    individual kitchen.
    Miele recommends using the full door opening angle of 115° for this freezer.
    Installation advice
    56
     
    						
    							Niche width
    A
    F 1811 Vi762 – 765 mm
    F 1911 Vi915 – 918 mm
    Building-in dimensions
    57
     
    						
    							Laying the electrical cabling
    and the pipework for the mains
    water supplyDoor front dimensions
    AB
    F 1811 Vi2029 mm 756 mm
    F 1911 Vi2029 mm 908 mm
    Building-in dimensions
    58
     
    						
    							Due to the size and weight of the
    appliance, it is essential that
    installation is carried out by two
    people.
    Tools and accessories
    required
    –Cordless screwdriver
    –Torx screwdriver
    –Hammer drill
    –Drill bits in various sizes, depending
    on materials
    – Hammer
    – 8 mm socket wrench
    – Adhesive tape
    – Pipe wrench
    – Spirit level
    – Try-square
    To secure the housing unit to a wall
    behind:
    –
    suitable wall plugs/fixing screws for
    the type and material of the wall.Other
    –Step ladder
    –Sack barrow
    –Wooden beams (min. 75 mm x
    100 mm) if required, to prevent
    tipping; length depends on width of
    building-in niche
    –Wood screws in various sizes
    Optional accessory
    –Side-by-side installation kit for
    side-by-side installation of two
    appliances
    Installation
    59
     
    						
    							Stainless steel fronts
    Stainless steel fronts and stainless steel
    look plinth grilles are available from
    your dealer or the Miele Spare Parts
    Department.
    Weight of the door front
    Before fitting the door front, ensure that
    the weight of the fronts does not
    exceed the maximum permitted:
    Appliance Max.
    weight
    of door front in kg
    F 1811 Vi 48
    F 1911 Vi 36
    Fitting a door front which is heavier
    than the maximum permitted could
    damage the hinges.
    Building into a peninsular run
    When built into a peninsular run, the
    rear of the building-in niche must be
    fitted with a kitchen furniture panel.
    Building-in at the end of a run
    of units
    If one side of the appliance is visible, a
    side panel is required.
    The side panel must be fixed to the
    wall, the floor and any furniture/units
    above before the appliance is placed in
    the niche.
    The size of the side panel must match
    that of the furniture panel opposite.
    Installation
    60
     
    						
    All Miele manuals Comments (0)

    Related Manuals for Miele F 1811 Vi Operating And Installation Instructions