Page 11
n Mount Jack Panel Boxes Mount the jack panel boxes near the controller, creating a “jack field.” You will need one jack panel box for every six telephones in your system. Ideally, the jack field will be two to six inches below the controller if the controller is wall-mounted. Mounting screws for the jack panel boxes are included in the kit. If you are installing the boxes on a sturdy supporting structure, such as studs or cross members, attach the boxes directly to the walls. If the walls are hollow,...
Page 12
n Run Cable To All Telephone Locations Select a cable extension kit with the right length of cable (100 or 200 feet) for one cable run. For runs over 200 feet, run a 200-foot cable, terminate it in a modular connecting block, plug in another cable, and repeat, up to a maximum of 1000 feet. Select a Cable Extension Kit with the right length of cable (100 or 200 feet) for one cable run. For runs over 200 feet, you will have to-run a 200-foot cable, terminate it in a modular connecting block, and plug in...
Page 13
n Install Modular Connecting Blocks Install a modular connecting block at each telephone location Find the modular connecting block from the Cable Extension Kit and the cable installation tool from the Wiring Installation Kit. Choose the location for the connecting block according to the figure. Cut the cable, making sure you allow at least 4 inches extra. 4 inches Modular connecting block TELEPHONE12 inchesLOCATION Cable Cable clipBaseboard Floor Fasten the cable to the connecting block as shown in...
Page 14
Typical cable installation for one telephone location. Cable clip Identical labels Cable TELEPHONE LOCATION Modular connecting block Finish your installation by routing cables to all other telephone locations and installing modular connecting blocks for each one. Be sure to label both ends of each cable run identically. Route your other cables and terminate each one in a modular connecting block. Be sure to label both ends of each cable run identically. Cable clip Dress the cables neatly through the...
Page 15
Step 4B Wiring Run, Using Customer Convenience Wiring Customer convenience wiring materials are available at your local phone store. Different situations require different materials. For instance, if a telephone location is less than 25 feet from the controller, you may choose to buy a 25’ D4BU line cord and plug one end in the modular connecting block of the telephone set and the other end in the corresponding modular connecting block in the controller. Use telephone wire clips to secure the cord to the...
Page 16
Typical Installation Using Customer Convenience Wiring Sample System Directory Label Controller 10 11 12 13 700A4 PLUG Telephone Labels630B Wall Connecting Block Wire Run Greater Than 50’Telephone Set Modular Cord (D4BU) 25’ Max. Wire Run Less Than 50’Telephone Set Cord (included with telephone) 625A 742B Wire Junction Box or 725A Modular Connecting Block Note to installers: The SPIRIT system requires a reversal in the station set wiring. This reversal is in the telephone (tinsel) cord that is packed...
Page 17
Step 5 Install Telephone Sets SPIRIT telephone sets are available in 6-Button and 24-Button models. The models are installed the same way. SPIRIT telephones are not like regular telephones and will not work if plugged directly into the Network Interface Jacks. Regular telephones will not work if they are plugged into the station jacks on your controller. n Record Installation Date Turn the telephone over. Write the installation date on the label located on the bottom of the set above the base. n Desk...
Page 18
Step 6 Connect System To Wiring Runs Connect the controller to the wiring runs. Following the numbers on your wiring run labels, plug one end of a jumper cord into the jack panel box or wire junction (see pages 7 and 14) and the other end of the jumper cord into the appropriate station jack on the controller. Plug the controller power cord into the AC outlet. Testing The System n Testing the Incoming Telephone Company Lines Use a standard telephone with a modular cord. Plug the cord into the jacks for...
Page 19
3. The left INTERCOM light should be lit if there is a 616 expansion unit installed correctly. If there is not an expansion unit installed, and the light does light, then there is a defect in the 308 controller. If a 616 expansion unit is present, check that the connector is properly installed (see the Expansion Unit Installation Instructions for further information) and then run the test again. If the left INTERCOM light still does not light, then there is a defect in either the 308 controller or the...
Page 20
Troubleshooting What To Do If You Have Trouble With Your System: For SPIRIT Communications Systems purchased from AT&T, a customer “hotline” (1-800-628-2888) is available to help you if you have questions about or trouble with your system. If you need assistance from the hotline, please follow these instructions BEFORE calling the hotline number. If you have purchased your system from an authorized dealer, these procedures will provide helpful information to have available before you contact your...