Page 731
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-65 The Modular Processor Data Module (MPDM) 21 General Features of the MPDM Both the MPDM stand-alone and multiple mount versions are contained in a 70A Data Mounting aluminum housing that is equipped with plastic front and rear covers. The MPDM, in general, offers the following data features: nSelecteddataratesupto64kbps nSynchronous or asynchronous...
Page 732
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-66 The Modular Processor Data Module (MPDM) 21 Switches The MPDM is equipped with the following switches: nORIGINATE/DISCONNECT — This switch is located on the front panel. It is used when originating and disconnecting a call from a terminal that does not have a BREAK key. nSELF-TEST — This switch is located behind the front faceplate. It is used to...
Page 733
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-67 The Modular Processor Data Module (MPDM) 21 Features of the AUDIX/CMS MPDM Package Functional Elements This preassembled package consists of the following par ts: nStand-alone housing nModular PDM nRS-232 interface card nOption Switch Settings Since the AUDIX/CMS MPDM is preassembled, you will need only to make the connections to the PBX, and set the...
Page 734
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-68 The Modular Processor Data Module (MPDM) 21 Features of the Video Teleconferencing MPDM Functional Elements The preassembled Video Teleconferencing MPDM consists of the following parts:. nStand-alone housing nModular PDM nV.35 interface card nRS-366 ACU interface card nV.35 M1 (ACCUNET D-Kit) NOTE: The label on the front of this MPDM renames the data...
Page 735
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-69 The Modular Processor Data Module (MPDM) 21 The Video Teleconferencing MPDM requires the following DIP switch settings for operation with ACCUNET Switched 56 kbps Digital Service or non-MPDM endpoints. Table 21-3. DIP Switch Settings on the Video Teleconferencing MPDM DIP Switch Setting OFF/LOW OFF OFF/300 OFF OFF/1200 OFF OFF/2400 OFF OFF/4800 OFF...
Page 736
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-70 The Modular Processor Data Module (MPDM) 21 Features of the High Speed Synchronous MPDM Optional Interface Cards There are two optional interface cards can be used with this MPDM package: nV. 3 5 — Normal DTR operation — Endpoint controls (asserts) the DTR lead nV. 3 5 D T R — DTR lead on the MPDM is always high — Endpoint has no control over the DTR...
Page 737
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-71 The Modular Processor Data Module (MPDM) 21 The baud rate depends on the setting of the speed option switches. When using ACCUNET Switched 56 kbps Digital Service, OFF/56K must be set to 56K. All other speed switches must be set to OFF. NOTE: Only one speed selection is allowed when the OFF/ANET switch is set to ANET. When FDX/HDX is set to HDX...
Page 738
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-72 The Modular Processor Data Module (MPDM) 21 nRS-366 ACU interface card PEC: 21614 Comcode: 103954582 nV.35 DTR interface card(This card has DTR always on.) PEC: 21615 Comcode: 105218101 nV.35 M1 * ACCUNET D-Kit(used to suppor t communications over DS1-robbed bit and ACCUNET facilities) PEC: 21616 Comcode: 105040141 n71A multiple mounting PEC: 21711...
Page 739
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-73 The Modular Trunk Data Module (MTDM) 21 The Modular Trunk Data Module (MTDM) Figure 21-22. The Modular Trunk Data Module, the Stand-alone Model Similar in appearance and function to the TDM, the MTDM is a multi-purpose data module configured to provide the digital switch interface to off-premises private line trunk facilities or a switch network...
Page 740
DEFINITY Enterprise Communications Server and System 75 and System 85 Terminals and Adjuncts Reference 555-015-201Issue 11 December 1999 Data Modules 21-74 The Modular Trunk Data Module (MTDM) 21 The MTDM can be configured to support the Data Call Setup, Modem Pooling, or Off-Premises Data-Only Extensions features. In addition to the standard data transmission rates supported by previous versions of the TDM (0.3, 1.2, 2.4, 4.8, 9.6, and 19.2 kbps), the MTDM supports data rates of 56 and 64 kbps for...