Page 171
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-41 Troubleshooting ISDN-BRI/ASAI Problems 5 Figure 5-11. Troubleshooting ISDN-BRI Problems (Page 2 of 2) PAGE NOYES END FROM 1 IS THE PROBLEM AFFECTING MOs ON MULTIPLE BRI-BD CIRCUIT IS THE PROBLEM AFFECTING MULTIPLE MOs ON THE SAME BRI-BD CIRCUIT A NO FOLLOW THE REPAIR PROCEDURE FOR BRI-PORT, BRI-DAT, ABRI-PORT, BRI-SET, OR ASAI-ADJ, AS...
Page 172
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-42 Troubleshooting ISDN-PRI Test Call Problems 5 Troubleshooting ISDN-PRI Test Call Problems An ISDN-PRI test call is placed across an ISDN-PRI user-network interface to a previously designated number in order to test ISDN capabilities of the switch, the trunk and the far end. An ISDN-PRI test call is also a maintenance procedure concerned...
Page 173
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-43 Troubleshooting ISDN-PRI Test Call Problems 5 Asynchronous Method The asynchronous method requires a Maintenance/Test circuit pack to be present in the system. In this method, 4 commands are used to start, stop, query, and list an outgoing ISDN-PRI test call: Before placing an outgoing ISDN-PRI test call, verify that the Feature Access...
Page 174
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-44 Troubleshooting the Outgoing ISDN-Testcall Command 5 The functions of the clear, list, and status commands associated with the ISDN Testcall are summarized below. clear isdn-testcall: enables you to cancel an in-progress ISDN-PRI test call and allow another test call to start. list isdn-testcall: enables you to list all the ISDN-PRI trunks...
Page 175
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-45 Packet Bus Fault Isolation and Repair 5 Packet Bus Fault Isolation and Repair The following procedures provide a means of isolating and correcting faults on both the packet bus and the various maintenance objects that use the packet bus. The packet bus is shared by all circuit packs that communicate on it, and a fault on one of those can...
Page 176
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-46 Packet Bus Fault Isolation and Repair 5 n‘‘Packet Bus Fault Isolation Flowchart’’ is the starting point for the troubleshooting process. It is used to determine if a failure of service is caused by the packet bus itself or by another maintenance object on the packet bus. n‘‘Correcting Packet Bus Faults’’ presents the procedures required to...
Page 177
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-47 Packet Bus Fault Isolation and Repair 5 Tools for Packet Bus Fault Isolation and Correction The following tools may be required on-site to perform packet bus fault isolation and correction. nTN771D Maintenance/Test circuit pack for use in standalone mode, and the connectors and cables necessary to install it (see the Maintenance/Test...
Page 178
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-48 Packet Bus Fault Isolation and Repair 5 The SPE interface to the packet bus is the TN1655 Packet Interface circuit pack. When SPEs are duplicated, there is one TN1655 in each SPE. The TN771D Maintenance/Test Circuit Pack (discussed in detail later) provides packet bus maintenance testing and reconfiguration capabilities. Packet Bus Faults...
Page 179
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-49 Packet Bus Fault Isolation and Repair 5 nTN771D Maintenance/Test: M/T-BD, M/T-DIG, M/T-PKT Circuit Packs That Use the Packet Bus This section describes the circuit packs that use the packet bus and the effects of circuit pack and bus failures on each other. Seven circuit packs can use the packet bus: The maintenance objects pertaining to...
Page 180
DEFINITY Enterprise Communications Server Release 6 Maintenance for R6r Volumes 1 & 2 555-230-126 Issue 2 January 1998 Responding to Alarms and Errors Page 5-50 Packet Bus Fault Isolation and Repair 5 nTN464F Universal DS1 circuit pack [UDS1-BD, ISDN-LNK] supports ISDN-PRI communications over an attached DS1 facility. It transports of D-channel signaling information over the packet bus, and B-channel data over the TDM bus. The Universal DS1 circuit pack has the same fault detection capabilities...