Page 81
OA&M Issue 3 May 1998 2-31 admin stream. After processing the received data, this program then waits for more data from the admin stream. The admin and signal stream files are always kept open by ipci_admin. Messages All of the following messages in the asai_log file are identified by a time stamp and the phrase ipci_admin: nStatus Messages — Two status messages are written to the asai_log file /usr/adm/asai/asai_log(4)by ipci_admin. One message indicates the beginning of the ipci_admin program....
Page 82
OA&M 2-32Issue 3 May 1998 See Also admin(7) asai_log(4) ipci(4) log_msgs(4) signal(7) link_restart(1) link_status(1)
Page 83
OA&M Issue 3 May 1998 2-33 ipci_off(1) Name ipci_off — Put specified IPCI board offline Synopsis ipci_off [n] Description This command is used to place board n offline. (The value of n can be 1, 2, 3 or 4.) When this is done, no new instances of communication between the UNIX ASAI adjunct and the ECS can be started. After executing this command, the board cannot be used for any signaling requests. To place it back online, it must be pumped using ipci_on. Exit Codes If an error is encountered or if...
Page 84
OA&M 2-34Issue 3 May 1998 ipci_on(1) Name ipci_on— Pump Software to IPCI Board(s) Synopsis ipci_on [n] Description ISDN software is placed on the IPCI board(s) and that software is initialized. The board is then considered to be online. If a value of n is specified, only that board is addressed. If no value of n is specified, the software is sent to all IPCI boards and all IPCI boards are placed into the online state. If n is used, its value will be 1, 2, 3 or 4. Board numbers are assigned to...
Page 85
OA&M Issue 3 May 1998 2-35 Notes This program is executed at boot time for all IPCI boards. It can be executed any other time for a board(s) that has successfully been placed offline. ipci_off should be used to take the board offline. Files /usr/adm/asai/asai_log /usr/adm/isdn/boot.bin /usr/adm/isdn/pcisdn.bin /dev/isdn/ipci/command See Also asai_log(4) boot.bin(4) command(7) ipci(4) ipci_off(1) pcisdn.bin(4)
Page 86
OA&M 2-36Issue 3 May 1998 ipci_stat(1) Name ipci_stat — Print Status of IPCI Board(s) Synopsis ipci_stat [n] Description If n is specified, a status report is printed for only that board. Otherwise, a status report is given for all boards. The report is printed to stdout. For each board, four items are printed: line_control Normally, the adjunct computer (UNIX ASAI adjunct) should be in control of the interface between the ISDN phone and the ECS. When this is the case, pc is printed. If the adjunct...
Page 87
OA&M Issue 3 May 1998 2-37 ipci_test(1) Name ipci_test — Test an IPCI Board Synopsis ipci_test[n] Description IPCI board n is tested. Operation If the board is online, nondestructive (loop back) online tests are done. If the board is offline, board memory tests are done. Return Value For success, 0 is returned. If an error is detected, 1 is returned. Output The online/offline status is printed on stdout followed by the results of the test. Errors are printed on stderr. Files /dev/isdn/ipci/command...
Page 88
OA&M 2-38Issue 3 May 1998 ipci_ver(1) Name ipci_ver — Print ipci product and software version information Synopsis ipci_ver Description Ipci product information is printed to stdout. This includes the name, date and version of the pumpware, the ipci product and the device driver as well as the board identification number. Exit Codes If there are no errors, the exit code is 0. Otherwise, the exit code is set to 1 to indicate an error.
Page 89
OA&M Issue 3 May 1998 2-39 isdn_alarm(1) Name isdn_alarm — Turn on or off isdn_bri maintenance alarming Synopsis isdn_alarm — a|d [-b1...-b4] [-t0...-tn] [-e] [-?] Description isdn_alarm uses the suspend and resume routines to turn on or off the isdn_bri alarms that are sent from the ECS. -a Activates alarming -d Deactivates alarming -b Specifies the board, where =1...4, is sent the message -t Sets the time-out to n seconds, where =0...n ; the default is -t3 -e Displays the exit codes list shown...
Page 90
OA&M 2-40Issue 3 May 1998 Exit Codes If isdn_alarm fails, one of the following exit codes is returned: 0 = The alarm condition was changed per request -1 = Failure due to inadequate memory -2 = Open stream failure -3 = Failure to send message to board -4 = Failure to receive messages from board -5 = Time-out while waiting to receive a message -6 = Layer 1 is down (could not attempt reset) -7 = Layer 2 failed to recover from reset -8 = State machine transitioning, try again