Page 81

OA&M
Issue  3  May 1998
2-31
admin stream. After processing the received data, this program then waits for 
more data from the admin stream.
The admin and signal stream files are always kept open by ipci_admin.
Messages
All of the following messages in the asai_log file are identified by a time stamp 
and the phrase ipci_admin:
nStatus Messages — Two status messages are written to the asai_log 
file /usr/adm/asai/asai_log(4)by ipci_admin. One message 
indicates the beginning of the ipci_admin program....

Page 82

OA&M
2-32Issue  3  May 1998 
See Also
admin(7)
asai_log(4)
ipci(4)
log_msgs(4)
signal(7)
link_restart(1)
link_status(1) 

Page 83

OA&M
Issue  3  May 1998
2-33
ipci_off(1)
Name
ipci_off — Put specified IPCI board offline
Synopsis
 ipci_off [n]
Description
This command is used to place board n offline. (The value of n can be 1, 2, 3
 or 4.) When this is done, no new instances of communication between the UNIX 
ASAI adjunct and the ECS can be started. After executing this command, the 
board cannot be used for any signaling requests. To place it back online, it must 
be pumped using ipci_on.
Exit Codes
If an error is encountered or if...

Page 84

OA&M
2-34Issue  3  May 1998 
ipci_on(1)
Name
ipci_on— Pump Software to IPCI Board(s)
Synopsis
 ipci_on [n]
Description
ISDN software is placed on the IPCI board(s) and that software is initialized. The 
board is then considered to be 
online.
If a value of n is specified, only that board is addressed. If no value of 
n is 
specified, the software is sent to all IPCI boards and all IPCI boards are placed 
into the
 online state.
If n is used, its value will be 1, 2, 3 or 4. Board numbers are assigned to...

Page 85

OA&M
Issue  3  May 1998
2-35
Notes
This program is executed at boot time for all IPCI boards. It can be executed any 
other time for a board(s) that has successfully been placed offline. ipci_off 
should be used to take the board offline.
Files
/usr/adm/asai/asai_log
/usr/adm/isdn/boot.bin
/usr/adm/isdn/pcisdn.bin
/dev/isdn/ipci/command
See Also
asai_log(4)
boot.bin(4)
command(7)
ipci(4)
ipci_off(1)
pcisdn.bin(4) 

Page 86

OA&M
2-36Issue  3  May 1998 
ipci_stat(1)
Name
ipci_stat — Print Status of IPCI Board(s)
Synopsis
ipci_stat [n]
Description
If n is specified, a status report is printed for only that board. Otherwise, a status 
report is given for all boards. The report is printed to stdout.
For each board, four items are printed:
line_control
Normally, the adjunct computer (UNIX ASAI adjunct) should be in control of the 
interface between the ISDN phone and the ECS. When this is the case, pc is 
printed. If the adjunct...

Page 87

OA&M
Issue  3  May 1998
2-37
ipci_test(1)
Name
ipci_test — Test an IPCI Board
Synopsis
 ipci_test[n]
Description
IPCI board n is tested.
Operation
If the board is online, nondestructive (loop back) online tests are done. If the 
board is offline, board memory tests are done.
Return Value
For success, 0 is returned. If an error is detected, 1 is returned.
Output
The online/offline status is printed on stdout followed by the results of the test. 
Errors are printed on stderr.
Files
/dev/isdn/ipci/command...

Page 88

OA&M
2-38Issue  3  May 1998 
ipci_ver(1)
Name
ipci_ver — Print ipci product and software version information
Synopsis
ipci_ver
Description
Ipci product information is printed to stdout. This includes the name, date and 
version of the pumpware, the ipci product and the device driver as well as the 
board identification number.
Exit Codes
If there are no errors, the exit code is 0. Otherwise, the exit code is set to 1 to 
indicate an error. 

Page 89

OA&M
Issue  3  May 1998
2-39
isdn_alarm(1)
Name
isdn_alarm — Turn on or off isdn_bri maintenance alarming
Synopsis
isdn_alarm — a|d [-b1...-b4] [-t0...-tn] [-e] [-?] 
Description
isdn_alarm uses the suspend and resume routines to turn on or off the 
isdn_bri alarms that are sent from the ECS.
-a
Activates alarming
-d
Deactivates alarming
-b
Specifies the board, where =1...4, is sent the message
-t
Sets the time-out to 
n seconds, where =0...n ; the default is -t3
-e
Displays the exit codes list shown...

Page 90

OA&M
2-40Issue  3  May 1998 
Exit Codes
If isdn_alarm fails, one of the following exit codes is returned:
 0 =  The alarm condition was changed per request
-1 =  Failure due to inadequate memory
-2 =  Open stream failure
-3 =  Failure to send message to board
-4 =  Failure to receive messages from board
-5 =  Time-out while waiting to receive a message
-6 =  Layer 1 is down (could not attempt reset)
-7 =  Layer 2 failed to recover from reset
-8 =  State machine transitioning, try again 