Page 341

Programming Manual Pages
Issue  3  May 1998
9-119
C_CONNECTED connect_list cause: See C_ALERTING.
connect_num: See C_ALERTING.
con_type is an optional plan_type_t 
structure that supplies additional information about 
the structure field that immediately precedes it 
(providing that the preceding field is not NULL). 
See 
C_ALERTING: con_num_type for 
more information concerning 
plan_type_t.
calling_num: See C_ALERTING.
calling_type is an optional 
plan_type_t structure that supplies 
additional...

Page 342

Programming Manual Pages
9-120Issue  3  May 1998 
C_ANSWERED call_id: See C_ALERTING.
answered_cause
 is an optional item that 
indicates a 
cause value. This item can 
assume any ECS-specified cause value or 
C_NUSE_LONG.
party_id: See C_ALERTING.
connect_num
: See C_ALERTING.
connect_type is an optional 
plan_type_t structure that supplies 
additional information about the structure field that 
immediately precedes it (providing that the 
preceding field is not NULL). 
See: 
C_ALERTING: con_num_type...

Page 343

Programming Manual Pages
Issue  3  May 1998
9-121
C_HOLD hold_list call_id: See C_ALERTING.
hold_num is a pointer to a null-terminated 
string indicating the number held. If the number is 
not supplied, the parameter is a null pointer.
hold_type is an optional plan_type_t 
structure that supplies additional information about 
the structure field that immediately precedes it 
(providing that the preceding field is not NULL). 
See 
C_ALERTING: con_num_type for 
more information concerning plan_type_t....

Page 344

Programming Manual Pages
9-122Issue  3  May 1998 
C_LOGOUT logout_listextension is a pointer to a null-terminated 
string indicating the extension of the agent who 
was logged out.
ext_type is an optional plan_type_t 
structure that supplies additional information about 
the structure field that immediately precedes it 
(providing that the preceding field is not NULL). 
See C_ALERTING: 
con_num_type for more 
information concerning 
plan_type_t.
logical is a pointer to a null-terminated string...

Page 345

Programming Manual Pages
Issue  3  May 1998
9-123
C_BUSY busy_list call_id is a structure of the type
call_id_t, where id_ptr points to a 
character array that indicates the ECS-assigned 
identifier of the call that generated the busy 
condition. 
id_length indicates the length of 
the call identifier.
party_id: See C_ALERTING.
called_num
: See C_CONNECTED.
called_type: See C_CONNECTED.
busy_cause is an optional parameter that 
indicates the cause of the busy event. It can be 
C_USER_BUSY, C_QUEFULL,...

Page 346

Programming Manual Pages
9-124Issue  3  May 1998 
C_DENIAL denial_list call_id: See C_ALERTING.
called_num: See C_CONNECTED.
called_type: See C_CONNECTED.
denial_cause is an optional integer value 
that indicates the cause of the reorder condition. It 
can be any ECS-specified cause value or    
C_NUSE_LONG.
pool: See C_ALERTING.
C_CUT_THROUGH cuthrw_list call_id:  See C_ALERTING.
party_id:  See C_ALERTING.
location is a mandatory parameter that 
shows where the progress indication is coming. It 
can be...

Page 347

Programming Manual Pages
Issue  3  May 1998
9-125
C_CONFERENCED conf_list bef_call_id is a mandatory structure of the 
type 
call_id_t, where id_ptr points to a 
character array that indicates ECS-assigned 
identifier of the call before conferencing.
 
id_length
 is the length of the call identifier.
aft_call_id is a mandatory structure of the 
type call_id_t, where id_ptr points to a 
character array that indicates the ECS-assigned 
identifier of the call after conferencing. 
id_length is the length of...

Page 348

Programming Manual Pages
9-126Issue  3  May 1998 
C_TRANSFERED tran_list bef_tranid is a mandatory structure of the 
type 
call_id_t, where id_ptr points to a 
character array that indicates the ECS-assigned 
identifier of the call before transfer. 
id_length 
is the length of the call identifier.
aft_tranid is a mandatory structure of the 
type call_id_t, where id_ptr points to a 
character array that indicates the ECS-assigned 
identifier of the call after transfer. 
id_length is 
the length of the...

Page 349

Programming Manual Pages
Issue  3  May 1998
9-127
C_OFFERED incall_listcall_id:  See C_ALERTING.
calling_num:  See C_ALERTING.
calling_type:  See C_CONNECTED.
called_num:  See C_CONNECTED.
called_type:  See C_CONNECTED.
uudata:  See C_ALERTING.
trk:  See C_ALERTING.
oli: See C_ALERTING.
domain_type
 can be C_TRUNK_GROUP, C_ACD_SPLIT, 
C_EXTENSION, C_HUNTGRP, C_VDN
, 
indicating the domain type of the party (trunk group 
access code, ACD split, extension, hunt group, or 
vector directory number)....

Page 350

Programming Manual Pages
9-128Issue  3  May 1998 
C_OFFERED 
(Continued)
incall_list  
(Continued)udata_type indicates the type of user data. It 
can be 
C_LOGIN_DIGITS,
C_CALL_PROMPTER
 or C_NUSE_LONG (login digits, call prompter information or not used).
timeout specifies the digit collection time out 
and is an integer value from 0 to 63 (the default 
value is 0).
The 
incomg_udata is a pointer to an optional 
character string of user data supplied with the call 
offered. If the string is not supplied...