DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 133 Costa Rica DS1 for ISDN Trunks to the PPT Page 1 of 1 DS1 CIRCUIT PACK Location: Name: E-1 ISDN Bit Rate: 2.048 Line Coding: hdb3 Signaling Mode: isdn-pri Connect: network...
Page 142
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 134 Czech Republic Czech Republic Ta b l e 2 5 shows the rec ommended c irc uit p ac ks. Table 25. Recommended and Available CPs in Czech Republic Equipment Equipment Type Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 220V/50Hz Ring Generator 25Hz Tone Detec tor > TN2182B > TN744D TN420C Tone Cloc k > TN2182B TN780 R2MFC...
Page 143
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 135 Czech Republic Feature Administration The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e ap p roval was award ed . The sc reens may have c hang ed sinc e that d ate. Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here....
Page 144
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 136 Czech Republic System Parameter Administration Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nFeature-Related System Parameters Ad ministration — Off-Premises Tone Detec t Timeout Interval (sec ond s): 5 — Nig ht Servic e Disc onnec t Timer (sec ond...
Page 145
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 137 Czech Republic — Outp ulse Without Tone? n (for d ial tone d etec tion) — Network Feed b ac k During Tone Detec tion? n (for dial tone detection) nSystem Parameters Customer Op tions — ARS? y (for d ial tone d etec tion) display system-parameters features Page 5 of 6 FEATURE-RELATED SYSTEM PARAMETERS...
Page 146
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 138 Czech Republic — Malic ious Call Trac e? y (for Malic ious Call feature) — Multifreq uenc y Sig naling ? y nSystem Parameter Country Op tions Ad ministration — Comp and ing Mode: A-Law — Dig ital Loss Plan: 14 — Analog Ring ing Cad enc e: 14 display system-parameters customer-options Page 1 of 2...
Page 147
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 139 Czech Republic — Analog Line Transmission: 14 — Tone Detec tion Mod e: 5 — Customized Individual Tones In this sec tion, c ustomized tone d efinitions follow the data-entry syntax as sp ec ified for entry on the Ind ivid ual Tone Ad ministration Sc reen: [ (Freq uenc y/Level)|silenc e|g oto)] [ (Duration ms)|(Step)] — Intrusion: n(425/-11.0)(350) n(silenc...
Page 148
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 140 Czech Republic n(425/-5)(650) n(silenc e)(650) n(goto)(1) —PBX Dial Tone: n(425/-5)(500) n(goto)(1) —Busy: n(425/-5)(350) n(silenc e)(350) n(goto)(1) — Ringback: n(425/-5)(1000) n(silenc e)(4000) n(goto)(1) — Call Wait 1: n(425/-11)(350) — Rec all Dial: n(425/-4)(150) n(silenc e)(150) n(425/-4)(150) n(silenc e)(150) n(425/-4)(1000) n(goto)(5) nC D R Sys t e m Pa...
Page 149
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 141 Czech Republic nSystem Parameter Multifreq uenc y Sig naling Ad ministration (Pay c lose attention to the values on the following three sc reens. They are c ritic al.) — Req uest Inc oming ANI (non-AAR/ARS)? n (To c hec k Inc oming ANI, enter yes. It is p art of the malic ious c all trac e op tion.) NOTE: On Page 2 of the Multifrequency-Signaling-Related...
Page 150
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 142 Czech Republic nARS Digit Analysis — Rte Pat: 2 (for d ial tone d etec t) display system-parameters multifrequency-signaling Page 2 of 3 MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS INCOMING FORWARD SIGNAL TYPES INCOMING BACKWARD SIGNAL TYPES (Tones from CO) (Tones to CO) Group-I...